  1. The Fermentation process gives it the bad taste...

    The Fermentation process gives it the bad taste when you drink it out of the bottle. Pouring it into a glass alows the gas to escape. Just like refrigerant!!! LOL
  2. Replies
    6
    Views
    854

    Thanks I will look at that tomorrow.

    Thanks I will look at that tomorrow.
  3. Replies
    6
    Views
    854

    Thanks Icehouse I have checked that and the...

    Thanks Icehouse I have checked that and the damper is actuating properly. When I open the door or lower the temp it will open.
  4. Replies
    6
    Views
    854

    Samsung Refrigerator RS366BASB

    Please help!!

    I am working on my new refrigerator model # RS366BASB and it has a grimlin.

    The typical protocal is working properly for several days until the refrigerator side warms up to 57...
  5. Replies
    43
    Views
    3,281

    There are two positions open in the Houston area...

    There are two positions open in the Houston area working for a lab that measures capacity and efficiency for residential and light commercial equipment. Let me know if you are interested.
  6. Replies
    31
    Views
    1,753

    The federal mandate is for manufacture to stop...

    The federal mandate is for manufacture to stop building equipment under 13 SEER. I do not know why any one would not try to up sell the customer and keep them as informed as possible. I would always...
  7. Replies
    20
    Views
    3,956

    Goodman uses 100 percent of Copeland compressors...

    Goodman uses 100 percent of Copeland compressors and all motors are AO Smith and GE. SO you can not say it is lower quality parts.
  8. Replies
    71
    Views
    6,881

    Is it possiable the their is a block on the...

    Is it possiable the their is a block on the equilization of the TXV causing the spring in the txv to close as the unit starts to run untill it eventually almost completely closes? I ran into a unit...
  9. Replies
    71
    Views
    6,881

    I seems to me that maybe the TXV have a...

    I seems to me that maybe the TXV have a restiction causing the spring to start to close after start up. I am not sure. BUt I have ren into a unit one time that was a EXTERNALLY EQUILIZED system that...
  10. Replies
    20
    Views
    3,956

    Installation is the most important thing to worry...

    Installation is the most important thing to worry about. The choice between Goodman, Carrier, Train go with the lowest cost 13 SEER is definately the way to go.
  11. Replies
    15
    Views
    1,237

    Curious. WHy does everybody slam having to work...

    Curious. WHy does everybody slam having to work on equipment. Isn't that bitting the hand that feeds the mouth. I can understand specific design flaws complaints. But just saying I have to work on...
  12. Replies
    5
    Views
    1,123

    Icemeister. is good. that is correct

    Icemeister. is good. that is correct
  13. Replies
    18
    Views
    4,581

    BOth increace and yes it should not Hunt but he...

    BOth increace and yes it should not Hunt but he asked the question Reduce airflow. ALso a block in the equilization tube, Sensing liquid on the bulb, Bad location of the bulb,low sub cooling, Ect....
  14. Replies
    15
    Views
    1,237

    MattM If they do not come with a certificate of...

    MattM If they do not come with a certificate of calibration you can simply take them to a calibration company and get a Cert with a NIST tracable standard backing it up. What city do you live in...
  15. Replies
    18
    Views
    4,581

    Casturbo. Yes when the TXV starts to close then...

    Casturbo. Yes when the TXV starts to close then the Suction Pressure drops and the Head pressure increases so the LBS/Hr of refrigerant, capacity, and Efficency all decreases.
  16. Replies
    7
    Views
    1,386

    CLear up the basement problem and replace the...

    CLear up the basement problem and replace the Furnace!!!!
  17. Replies
    12
    Views
    1,400

    If the unit is a Heat pump then the peversing...

    If the unit is a Heat pump then the peversing valve is in the wrong position and if it is a stait cooling unit the outdoor unit is not suppose to be running in the heat mode. Either way no reason to...
  18. Replies
    12
    Views
    1,400

    Docholiday. is correct sounds like there is...

    Docholiday. is correct sounds like there is problem with the wiring. Call him today it is running in the cooling mode.
  19. Replies
    18
    Views
    4,581

    TO clear up things the TXV has to have Out vap...

    TO clear up things the TXV has to have Out vap superheat of 12-15 deg to ensure there is no liquid refigerant after the TXV(this will cause the hunting not good) so dependant on the line set length...
  20. Replies
    11
    Views
    6,132

    DRUMN91 is correct USE THE ADVISE>

    DRUMN91 is correct USE THE ADVISE>
  21. Replies
    27
    Views
    4,082

    Bootom line TODAY they are both good equipment. I...

    Bootom line TODAY they are both good equipment. I promise you. Goodman has completely turned around in the past years. Carrier lately has had a few problems out of there plant in Mexico (leaks in the...
  22. Replies
    19
    Views
    5,906

    Why use a TXV

    The reason that a TXV is better that a piston is beocuse your TXV is suppost to maintain the superheat at any condition. If your Evaporator is not oversized to much you will not see a big advantage...