Search:

Type: Posts; User: BaldLoonie

Page 1 of 20 1 2 3 4

Search: Search took 0.19 seconds.

  1. Try United Refrigeration In Arkansas: 3903...

    Try United Refrigeration

    In Arkansas:

    3903 Elliott Avenue
    Springdale, AR 72762-4932
    Phone: 479-927-2400
  2. Unless it has a broken cap tube or equalizer that...

    Unless it has a broken cap tube or equalizer that is visually seen, sure can't diagnose the TXV with no gas. Something very fishy here. Might be time for a 2nd opinion. We started offering free...
  3. That old Fedders sure lasted

    That old Fedders sure lasted
  4. Replies
    14
    Views
    357

    Measure the width

    Measure the width
  5. Replies
    14
    Views
    357

    Measure the width of the furnace?

    Measure the width of the furnace?
  6. Replies
    6
    Views
    195

    Everyone has their own opinion on brands and best...

    Everyone has their own opinion on brands and best size of company. We're an 11 tech company, big enough to get the job done, small enough to have personal service and customers get to know us. We...
  7. Hard to tell staging unless your thermostat tells...

    Hard to tell staging unless your thermostat tells you. There will be a very slight increase in airflow and the outdoor fan may speed up a hair. There isn't that much difference between low & high on...
  8. Replies
    10
    Views
    244

    At one point, EMI, but that's likely changed.

    At one point, EMI, but that's likely changed.
  9. Replies
    4
    Views
    177

    Apparently that didn't help. Any commercial gurus...

    Apparently that didn't help. Any commercial gurus have feedback?
  10. Replies
    2
    Views
    169

    Just at a WAG, 1500 sq ft in mid Ohio sounds like...

    Just at a WAG, 1500 sq ft in mid Ohio sounds like 70K and 2.5 ton. At least the typical home you describe next door in Indiana would have that. The 90K furnace will want to move A LOT of air and...
  11. Replies
    11
    Views
    241

    I can tell you in 30 seconds but that's getting...

    I can tell you in 30 seconds but that's getting too close to site rules about assisting DIY. You say you have a pro installing it so let him get the model #.
  12. Looks great to me!

    Looks great to me!
  13. Replies
    23
    Views
    820

    Way to go Brent!!!!! :cheers:

    Way to go Brent!!!!! :cheers:
  14. The ventilation settings are if you have some...

    The ventilation settings are if you have some kind of vent damper or ERV/HRV. If you don't have them, it doesn't apply to you.
  15. It is an AHRI rated match to put the 048 air...

    It is an AHRI rated match to put the 048 air handler on the 060 outdoor unit. Noise means insufficient ducting for the 1600 CFM or if you take return directly off the unit, some sound deadening...
  16. Replies
    11
    Views
    241

    Your dealer can ask the supplier or may have...

    Your dealer can ask the supplier or may have access to asdealernet or comfortsite.
  17. Replies
    14
    Views
    357

    Didn't see one that ended in 0. I looked in...

    Didn't see one that ended in 0. I looked in Preston Guide. May have some stuff at home on Singer.
  18. Replies
    14
    Views
    357

    I think the model # is the entire line so won't...

    I think the model # is the entire line so won't tell a specific furnace. If you can find a GB-2104 type number, the 4 tells size. Also most furnace rating plates flat out said input & output.
    ...
  19. Replies
    7
    Views
    224

    1. Today's units don't have the latent capacity...

    1. Today's units don't have the latent capacity of the antiques
    2. Today's units take sometimes twice as long to reach full latent capacity

    So if you are in a humid climate at all, oversizing may...
  20. Replies
    14
    Views
    357

    Why do you need to find the output of that relic?

    Why do you need to find the output of that relic?
  21. The YHJD doesn't mention the defrost system. The...

    The YHJD doesn't mention the defrost system. The YHJF says demand defrost that will eliminate hundreds of unnecessary defrosts each winter compared to the timer system (which Carrier uses).
  22. Model #s? York has 2 LX units, difference in...

    Model #s?

    York has 2 LX units, difference in features and performance. Never heard of York using microchannel coils in heat pumps. York does use recip compressors in some models, personally I'd...
  23. 3 tons for 1100 sq ft in Boston? Wow! Where...

    3 tons for 1100 sq ft in Boston? Wow!

    Where are the temp readings being taken? Need to be right over the coil to see how the A/C is doing.
  24. Replies
    2
    Views
    154

    Don't add to existing, gotta start from scratch....

    Don't add to existing, gotta start from scratch. With the price of R22 so low, the alternatives aren't to interesting to us. Can always count on the genuine article. When the time comes, we'll likely...
  25. There's 18 and 20 in both brands.

    There's 18 and 20 in both brands.
  26. Replies
    15
    Views
    538

    I've usually seen that when something was a...

    I've usually seen that when something was a direct short in the low voltage.
  27. Platinum 18 is identical except for the cabinet.

    Platinum 18 is identical except for the cabinet.
  28. Replies
    9
    Views
    303

    You aren't comparing like A/C units. Furnace are...

    You aren't comparing like A/C units. Furnace are essentially the same feature wise.

    The Trane is a high end unit, overkill for your area unless money is no object.

    The Lennox at a guess I'm...
  29. You better find out for sure about the loop...

    You better find out for sure about the loop capacity.

    I'll bet anything that your duct system for each unit barely supports the size that is there so if you go bigger, even if they are 2 stage,...
  30. Replies
    2
    Views
    172

    Rheem is all demand. I think some of the high...

    Rheem is all demand. I think some of the high end Lennox are too.

    They do claim the Spine Fin can hold more frost before reducing airflow.
  31. Replies
    16
    Views
    393

    The 4SCU13LE -5 models are back to Copeland.

    The 4SCU13LE -5 models are back to Copeland.
  32. Replies
    21
    Views
    400

    I wouldn't use a IR thermometer to check temp...

    I wouldn't use a IR thermometer to check temp drop.
  33. Replies
    102
    Views
    2,602

    The upstairs gets 14.50 SEER, the TXV bumps it...

    The upstairs gets 14.50 SEER, the TXV bumps it from 14 to 14.50. The downstairs also rates out at 14.50.
  34. You'd want a 5 minute time delay to prevent short...

    You'd want a 5 minute time delay to prevent short cycling.
  35. Replies
    1
    Views
    137

    Yea, sure would be handy to compare like...

    Yea, sure would be handy to compare like products.

    The Rheem is a nice system. The new heat pump but the old furnace though 2 stage with variable speed blower. If you could get the R802V you could...
  36. Replies
    16
    Views
    393

    Lotta advantages of the EFV. Steady airflow as...

    Lotta advantages of the EFV. Steady airflow as duct conditions change, better airflow with higher statics, 1/2 speed constant fan which uses very little juice, dehumidify on demand with appropriate...
  37. Replies
    4
    Views
    177

    I'll move you next door to commercial!

    I'll move you next door to commercial!
  38. Replies
    2
    Views
    125

    Probably old age!!! Have to go with National...

    Probably old age!!!

    Have to go with National Comfort Products or First Company for another through the wall unit unless the condo complex allows units on the ground and run copper lines up to the...
  39. Same thing, same assembly lines. Yes, the...

    Same thing, same assembly lines.

    Yes, the dual recip 20i is going away in favor of the 2 units with the inverter scroll. Both brands had them, American Standard didn't have the fancy top.
  40. Replies
    7
    Views
    176

    3M filters especially as they start to get dirty...

    3M filters especially as they start to get dirty are very restrictive. Media filters are so much less restrictive than 1" pleated.
  41. It worked :) Hunter, every one we've found and...

    It worked :)

    Hunter, every one we've found and changed the TXV on last year before this cleaner stuff came up had suction around 90, high superheat, not unusual head. Also may want to check back...
  42. Replies
    26
    Views
    5,145

    Not sure what a Brother unit is. Trane's bottom...

    Not sure what a Brother unit is. Trane's bottom feeder is the Ameristar line made by Midea of China. Looks dark gray like an Ameristar. They may have a rotary in a small size. They are cheap, why...
  43. Replies
    102
    Views
    2,602

    What are the complete model #s in & out of both...

    What are the complete model #s in & out of both systems. That way we can look up the efficiency.
  44. Replies
    3
    Views
    99

    1600 CFM

    1600 CFM
  45. Since it says ON and AUTO both, still say to...

    Since it says ON and AUTO both, still say to check scheduling.
  46. Replies
    12
    Views
    359

    You'll freeze it up!

    You'll freeze it up!
  47. A well designed (which never happens) duct system...

    A well designed (which never happens) duct system with zoning in mind can be done without a bypass. Just need to have enough capacity in each zone to keep from overheating or triggering the low limit...
  48. No, it's in the temperature programming. Each...

    No, it's in the temperature programming. Each time period can have a choice of auto, circ and on fan. The homeowner just needs to get into the scheduling and look at every period for one not set at...
  49. Doesn't 407C need POE oil?

    Doesn't 407C need POE oil?
  50. Replies
    16
    Views
    450

    Only Carrier repeated compressor failures I know...

    Only Carrier repeated compressor failures I know of is their use of the Bristol "twin single".