  1. Thread: Outdoor W I

    by dorvs
    Replies
    4
    Views
    396

    If the box is in good condition then yes it can...

    If the box is in good condition then yes it can last another 10-15 years if done correctly. My guess is that when it was built it was never caulked. If it can be shut down for a few days to thaw the...
  2. Thread: HVAC School?

    by dorvs
    Replies
    9
    Views
    1,543

    what part of WI are you in? I have a few contacts...

    what part of WI are you in? I have a few contacts in that part of the world. Also you can go to the local distributers G.A. Larson,johnstone etc. and talk to the counter people to see if companys are...
  3. Replies
    4
    Views
    536

    Check the scraper blades for excessive wear. Also...

    Check the scraper blades for excessive wear. Also check to make sure the screw is spinning inside. Just because the pully is spinning does not mean screw is. the berings can be junk, you can check by...
  4. Replies
    14
    Views
    1,280

    i would aslo add a O-52hh capt t drier

    i would aslo add a O-52hh capt t drier
  5. Replies
    41
    Views
    2,912

    I have worked at a supply house before and would...

    I have worked at a supply house before and would not sell anything to joe blow off the street, not even air filters. To me it was not worth pissing off a contractor who possibly did service for them....
  6. Replies
    24
    Views
    3,207

    where was the voltage corrected? were the...

    where was the voltage corrected? were the condenser fan motors rewired in the motors?
  7. Trane comfortsite you may have to register to be...

    Trane comfortsite you may have to register to be able to get to all the good info. But they have service facts from 40 plus years ago.
  8. Replies
    17
    Views
    3,029

    Did you install the correct drier? HP take a 2...

    Did you install the correct drier? HP take a 2 way drier.
  9. if you lived down south the higher seer would be...

    if you lived down south the higher seer would be worth it. saying that you live in a place where a/c will run possably 2 months a year, and at that it will be hit and miss a day here a day...
  10. Replies
    27
    Views
    2,124

    if it is only 8 months old it should still be...

    if it is only 8 months old it should still be under warranty. get a new compressor then fix what took it out.
  11. Replies
    9
    Views
    1,396

    even oem's rebuild their compressors thats why...

    even oem's rebuild their compressors thats why their is a core charge on most of them. they want them back.
  12. Replies
    3
    Views
    617

    depending on what part of the country you are...

    depending on what part of the country you are from yes. and also the application.
  13. Replies
    49
    Views
    2,953

    I was working on a t49 last week and found a leak...

    I was working on a t49 last week and found a leak on the outlet of the evap. coil, right at the face of the steel where the tube comes out. Took some time to pin point.
  14. Replies
    2
    Views
    827

    manurup/danfoss compressors

    anybody haveing issues or problems with them?
  15. Replies
    14
    Views
    1,409

    put a simple stat like a honeywell 1029 to...

    put a simple stat like a honeywell 1029 to dissable the condenser when it reaches whatever temp you set it to. when it warms up you'll have a/c again.
  16. Thread: BDP 585 help

    by dorvs
    Replies
    2
    Views
    2,269

    25 years old they got their money out of it,...

    25 years old they got their money out of it, replace it.
  17. Replies
    13
    Views
    875

    20 ton breaker was 9 amp

    20 ton breaker was 9 amp
  18. Replies
    13
    Views
    875

    Found the problem. It was a bad circut breaker....

    Found the problem. It was a bad circut breaker. CB1
  19. Replies
    13
    Views
    875

    perfect. I will check that as well and no i dont...

    perfect. I will check that as well and no i dont have the software. Did not know about it till now. This is the first rtu that i had my hands in with this software. Thanks for the input
  20. Replies
    13
    Views
    875

    smokes are smoke detectors. from what i found out...

    smokes are smoke detectors. from what i found out today is that the "smokes" that are installed are tempermental to the cold weather that we have had. 20 to 30 below. I have checked rotation and it...
  21. Replies
    13
    Views
    875

    and yes the supply fan is vfd. I contacted...

    and yes the supply fan is vfd. I contacted carrier tech. support but only managed to piss them off. and they were no help.
  22. Replies
    13
    Views
    875

    no codes like that. the code yesterday was for...

    no codes like that. the code yesterday was for reverse rotation and today the smokes. Thanks to the button pushers aka maintence guys dont know for sure the #'s.
  23. Replies
    13
    Views
    875

    carrier control issue

    I have been working on a carrier with a comfort link control for the past 2 days and cant figure it out. The first call was no heat, the only thing the rtu is really use for is a/c in the summer. But...