  1. Replies
    17
    Views
    1,781

    Well hvac17011. I dont think you should be...

    Well hvac17011. I dont think you should be hitting those digital scrolls with a hammer. Thats something us working men do to try and get a customer some ac. It never works but its worth a try. Just...
  2. Replies
    17
    Views
    1,781

    Before i put power back to it after the internal...

    Before i put power back to it after the internal closed i hit it with a hammer a few times. Once it came on there was no doubt she was shot. It sounded all broken apart inside. And no i dont think...
  3. Replies
    13
    Views
    1,421

    Seems close without actually doing any math. One...

    Seems close without actually doing any math. One thing i would recomend is staging or some type of load control. Spaces like this are always problematic if the unit isnt sized right. You need enough...
  4. Replies
    17
    Views
    1,781

    Kinda what i thought. A system running that low...

    Kinda what i thought. A system running that low on charge and then actually getting loaded up and doing work could cause a failure. You just sorta feel bad when stuff like that happens.
  5. Replies
    17
    Views
    1,781

    Oops. This doesnt belong here.

    Oops. This doesnt belong here.
  6. Replies
    17
    Views
    1,781

    compressor died! Why?

    So yesterday i ran a no cooling call. 5ton trane heat pump for a training room. Low pressures, 40deg superheat, no subcooling, flahsing sight glass, and going off on freeze stat. I charged the unit...
  7. Replies
    22
    Views
    1,690

    Most likely pascone10 is right. If the thing...

    Most likely pascone10 is right. If the thing rings out at 2-3ohms across all terminals it should run or do something when 480v is put to it. I would throw your amp clamp on it before it starts....
  8. Replies
    26
    Views
    2,760

    Yea there is no debating that we have to do it. ...

    Yea there is no debating that we have to do it. My supervisor doesnt like it any more than anybody else but his hands are tied. I just want to be as comfortable as possible. Right now we have to...
  9. Replies
    26
    Views
    2,760

    Most likely we will be paying for them out of our...

    Most likely we will be paying for them out of our uniform fund. This is money the company puts in for us to use. From what i seen so far the shirts can run 100 bucks. Im not trying to be a smart a**...
  10. Replies
    33
    Views
    3,325

    I dont deal with anything like detroit or st...

    I dont deal with anything like detroit or st louis but Harrisburg has its ghetto like anywhere else. Our company is pretty decent about letting you decide for yourself if you wanna run the call....
  11. Replies
    26
    Views
    2,760

    Im with acfixr. All the videos i ever seen of...

    Im with acfixr. All the videos i ever seen of arc flashs were in large panels, switch gears, or on power lines. My uncle actually got seriously injured as a linemen when a insulator failed and...
  12. Replies
    26
    Views
    2,760

    nfpa 70e clothing

    My company is going to start making the commercial service techs wear the arc flash, fire proof clothing. Do any of you guys wear it now and if so is it as horrible as it sounds. Also what brands...
  13. Replies
    42
    Views
    14,808

    If you are applying at a facility that has only...

    If you are applying at a facility that has only one type of chiller/boiler than call anyone and everyone you can to find out what they have and at least be familiar with what it is. I went on a...
  14. Replies
    5
    Views
    619

    Well played young man!

    Well played young man!