Search Results - HVAC-Talk: Heating, Air & Refrigeration Discussion

Search:

Type: Posts; User: summit-dude

Page 1 of 6 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    1
    Views
    184

    VoyagerII or voyagerIII?

    VoyagerII or voyagerIII?
  2. Replies
    14
    Views
    670

    Don't forget to bind your llids when you restore...

    Don't forget to bind your llids when you restore the config...
  3. Replies
    14
    Views
    670

    We're you able to back up the old 530? If you...

    We're you able to back up the old 530? If you were able to you can just dump that config into your new 530. If you didn't you will need to configure the new ch530. Be careful when you do because if...
  4. Replies
    14
    Views
    670

    You beat me to the post! I have only had to...

    You beat me to the post! I have only had to replace one CH-530 in my 10 year career at trane! Usually someone leaned on the contrast button...
  5. Replies
    11
    Views
    516

    Scroo is exactly right. If the box is configured...

    Scroo is exactly right. If the box is configured as a varitrane box and you have a pressure transducer installed the box will enter pressure dependent mode if the transducer doesnt read airflow....
  6. Replies
    11
    Views
    516

    One important detail here; the BCU. What kind of...

    One important detail here; the BCU. What kind of BCU do you have. If its a BMTX you can land the cards on either of the comm 4 links. If its a BMTW you will need a comm 4 card to install in one of...
  7. Replies
    2
    Views
    150

    Bandwidth BAC-net IP

    Anyone know of a good freeware bandwith tool I can use to check my IP network?
  8. Replies
    5
    Views
    198

    Maybe the triacs are trashed on the VV-550 check...

    Maybe the triacs are trashed on the VV-550 check those as well... Also make sure the * ** enable box is unchecked. If the minimum is set to 0 and the stat is ran a to ** it will override the damper...
  9. Replies
    6
    Views
    255

    I have. If its the board I just dealt with you...

    I have. If its the board I just dealt with you cant adjust the UCM address on it except through the command module. We ended up having to change the boards to the Comm-4 module that is now supported....
  10. Replies
    9
    Views
    406

    Browse to your VAV and select the status pages....

    Browse to your VAV and select the status pages. on the first page you will see space temperature setpoint BAS. Click on the blue arrow and an override dialog box will show up. If you are in the...
  11. Replies
    15
    Views
    579

    Comm-5 is actually 4500 feet before you need a...

    Comm-5 is actually 4500 feet before you need a repeater, you can add another 4500 feet after that.Comm 4 doesnt support bus topology but for something we dont support when done properly it works...
  12. Replies
    15
    Views
    579

    Looks like you found it! lol. We are also taught...

    Looks like you found it! lol. We are also taught this at the factory we dont support free topology or bus topology only a daisy chain. Our tech support gurus will actually cut you off your backbone...
  13. Replies
    1
    Views
    221

    Run a pid loop to 300% add your next pump at 95%...

    Run a pid loop to 300% add your next pump at 95% then divide the output by the number of pumps requested to keep your pump speed the same. Store your current lead in a local variable and add one to...
  14. Replies
    2
    Views
    132

    Try toggling the occupancy snvt on the chiller...

    Try toggling the occupancy snvt on the chiller that's not starting for you. We typically write to the occupancy command not stop start.
  15. Replies
    3
    Views
    288

    Ok the 11 domain will be DSN A we use a 1 domain...

    Ok the 11 domain will be DSN A we use a 1 domain to install in a Bcu 11 means the link was formatted with Rover if yor domain was 13 the link would have been formatted with a Bcu. All you bindings...
  16. Can't believe you have one of these. Late 90's...

    Can't believe you have one of these. Late 90's the 2/3/4 cards had a problem with the software. After it logged so many comm errors it would start scanning comm 3. The module you have was a very cool...
  17. Replies
    9
    Views
    406

    When a Tracer SC discovers equipment for the...

    When a Tracer SC discovers equipment for the first time it turns the local set point off. Browse to your VAV and look at the status pages, look for space temperature set point BAS. If that point is...
  18. Replies
    9
    Views
    406

    Log in as the user, on the trane toolbar on the...

    Log in as the user, on the trane toolbar on the right select user, preferences, about little more than half way down the page the data field for data display units preferences will allow you to...
  19. Replies
    9
    Views
    1,520

    You shouldn't need this add on to forward event...

    You shouldn't need this add on to forward event classes. When is the last time summit was closed and the database compacted? How large is your database? How many workstations and Bcu's? Sounds almost...
  20. Replies
    15
    Views
    579

    Trane standard: level 4 twisted pair, more than...

    Trane standard: level 4 twisted pair, more than 60 devices requires a repeater near the middle of the device count, 105 ohm resistors on both ends of each segment. Bcu's will not be happy unless this...
  21. Replies
    5
    Views
    964

    Sounds like your IT guy needs to do a little work...

    Sounds like your IT guy needs to do a little work and make sure that the bcu ip address isnt being assigned out in a dhcp pool just a thought
  22. Replies
    6
    Views
    819

    Trane has several variables that only apply to...

    Trane has several variables that only apply to the trane profile for an MP-581 used in summit and are not lon certified these are like a multi state point but probably won't mean much to you. You...
  23. Thread: Loetec LIP

    by summit-dude
    Replies
    10
    Views
    1,361

    I have the manuals and their tech support has...

    I have the manuals and their tech support has been no help ready to give up and try another way of doing the integration. Tried the settings as a foreign device no BBMD b/c I already have one on the...
  24. Thread: Loetec LIP

    by summit-dude
    Replies
    10
    Views
    1,361

    ok got firmware updated but it still wont serve...

    ok got firmware updated but it still wont serve up any points, I have no duplicate addresses, Baud rates match any ideas
  25. Replies
    10
    Views
    1,355

    It is a standard ISA card slot 10/100 m card and...

    It is a standard ISA card slot 10/100 m card and just about any card will work as long as it is jumper configurable for 10 meg 1/2 duplex