  1. I do not have a specific gas dryers selected at...

    I do not have a specific gas dryers selected at this time but since appliances can change I want it set up for the future. It will be gas as that is how it is plumbed. I also have read smooth...
  2. Roof penetration for dryer vent. What materials?

    Suggestions on materials for gas dryer that must vent upwards about a 5 foot run. Cannot vent out the side due to window distances being too close.

    From the bottom up --> drywall---->then 1ft...
  3. Replies
    62
    Views
    5,182

    Wow, a heater repairman that thinks furnaces go...

    Wow, a heater repairman that thinks furnaces go into stage 2 heat after ten minutes.
  4. Replies
    62
    Views
    5,182

    I'm stuck with the company that did the install...

    I'm stuck with the company that did the install so I have to work thru it. The number of hack jobs is ONE. The wrong equipment and initial single return air added to level 2. Red flags don't...
  5. Replies
    62
    Views
    5,182

    Picture shots of NEST

    These are random log screen shots of playing with the nest thermostat, varying conditions, pre and post duct work as well. Not to read into the logs but just to see the example.

    363911363921
  6. Replies
    62
    Views
    5,182

    Nest version 2 thermostat supporting 2 stage heat...

    Nest version 2 thermostat supporting 2 stage heat and 2 stage cool. Locked user access for temp range 68-72 heat. Not in learning schedule mode and away disabled.
  7. Replies
    62
    Views
    5,182

    Great point. The units are not zoned but at the...

    Great point. The units are not zoned but at the same time there is nothing that prevents tenants from closing
    off their vents and thereby restricting airflow.
  8. Replies
    62
    Views
    5,182

    Here is where I am at: 363861 So the new...

    Here is where I am at:

    363861

    So the new duct work is added, that is the 3 supplies on the upper level from a 10 in spiral ducts (right). The 12" return (left) was done before. So all of this...
  9. Replies
    62
    Views
    5,182

    right now there is a 4 ton 16 seer 2 stage unit...

    right now there is a 4 ton 16 seer 2 stage unit installed that will be replaced as well. Kinda hard for me to see it go. But also equipment hight including this efficient coil make the unit too...
  10. Replies
    62
    Views
    5,182

    I don't have all the data just discussion. The...

    I don't have all the data just discussion. The static pressure was high based on insufficient place to relieve the air. On the main level there is a large return panned between two joists with a 10...
  11. Replies
    62
    Views
    5,182

    A 12" diameter return was previously added to the...

    A 12" diameter return was previously added to the 2nd level.
  12. Replies
    62
    Views
    5,182

    Correction the heat load was not 75K but rather...

    Correction the heat load was not 75K but rather heat calc indicated I need a 75K unit after efficiencies and altitude were considered.
  13. Replies
    62
    Views
    5,182

    The factory default for this furnace on page 47...

    The factory default for this furnace on page 47 in figure 44 for jumper P7 is "none" and will never go into high fire unless a two stage thermostat calls for high fire. If the jumper is set to...
  14. Replies
    62
    Views
    5,182

    Forced company to do a complete analysis. Manual...

    Forced company to do a complete analysis. Manual J said I only had 900 CFM ductwork capacity and heat load needed was about 75K. Three new supplies are being added to the upper level to enable 500...
  15. Replies
    62
    Views
    5,182

    Tomorrow (Friday Jan 1) I meet with the sales and...

    Tomorrow (Friday Jan 1) I meet with the sales and installers at the premises.

    Based on what I have learned here I should ask for the following.

    Since I am at a mile high how much does that...
  16. Replies
    62
    Views
    5,182

    Thanks for the info. Having 5 ton capabilities...

    Thanks for the info. Having 5 ton capabilities does not mean it is operating at 5 ton as I understand it. Even the next two sizes down have 5 ton "capabilities". Due to height restrictions they...
  17. Replies
    62
    Views
    5,182

    OK so still sizing up my options before I go back...

    OK so still sizing up my options before I go back the the contractor. One fear I have is, lets say the 105 is replaced with the 75K BTU unit. And then stage one runs shortly (12-15 as ROBO says)...
  18. Replies
    62
    Views
    5,182

    beenthere: Thank you this is indeed helpful. I...

    beenthere: Thank you this is indeed helpful. I will go back in about a week and they guaranteed up front in writing that they will change the equipment out if I am not satisfied so I need to gather...
  19. Replies
    62
    Views
    5,182

    As I said in my initial post, a 162K BTU...

    As I said in my initial post, a 162K BTU Thermopride furnace was displaced.

    The system is not 100% ducted for a coal furnace. There are additions to the property of 500sq ft served by the same...
  20. Replies
    62
    Views
    5,182

    Not true

    Not true
  21. Replies
    62
    Views
    5,182

    I'm not seeing high fire unless I turn the t stat...

    I'm not seeing high fire unless I turn the t stat up about 3 degrees. If I leave the t stat at 70 degrees and it is 30 degree nights and 50 degree days the duty cycle is about 33 percent. Roughly...
  22. Replies
    62
    Views
    5,182

    I eat yummy crow and humbly apologize. The...

    I eat yummy crow and humbly apologize. The product specifications in another marketing document says high heat 1604 and low heat 1400. But I do not see that high of speed in the manual except for...
  23. Replies
    62
    Views
    5,182

    350461350471 The furnace is using BOTH stages,...

    350461350471

    The furnace is using BOTH stages, only stage 2 if I make like a 3 degree delta T call for heat. Or at the tail end of a run. I am using the NEST thermostat generation 2 that...
  24. Replies
    62
    Views
    5,182

    I do not believe your statement to be true. Is...

    I do not believe your statement to be true. Is it possible you could provide some facts here. I am not an HVAC tech but I read the manual in the sections for setting the CFM and temperature rise...
  25. Replies
    62
    Views
    5,182

    So, setting aside the duct capabilities, CFM for...

    So, setting aside the duct capabilities, CFM for one moment and we just talk about energy. If the heat loss calculation for a property is 60K what size of a 2 stage furnace is optimum? Sized to...