    Please Presedente send me a copy. Thanks a lot...

    Please Presedente send me a copy.
    Thanks a lot in advance!
  2. Replies
    33
    Views
    5,487

    I'm glad you got the humor Hvac5646, because I'm...

    I'm glad you got the humor Hvac5646, because I'm not very keen on languages. As for Gravity suggestion to increase pipe diameter to correct size I think it's a good idea. I know Trane gives 2...
  3. Replies
    33
    Views
    5,487

    Should have been said about adding subcooler with...

    Should have been said about adding subcooler with largher compressor before but want to observe another points of view.
  4. Replies
    33
    Views
    5,487

    Just to explain our Client banking group...

    Just to explain our Client banking group replacing the old aged 3 months burned out compressor isn't enough. I think the new one more powerful Copeland scroll have been working for 1 year will die...
  5. Replies
    33
    Views
    5,487

    But if the pressure drop is up to 30 psig due to...

    But if the pressure drop is up to 30 psig due to long piping I'd rather put largher compressor in first after replacing the burning out compressor.
  6. Found an old York fancoil sensor in my garage....

    Found an old York fancoil sensor in my garage. Got it to replace faulty one in Mammoth heat pump. Have noticed the label attached to the faulty thermistor wire there.358051 The label reads...
  7. Replies
    33
    Views
    5,487

    Sometimes you can't come back to the site in a...

    Sometimes you can't come back to the site in a pair of days. In this case I wouldn't install a strainer. One liquid strainer is enough.
  8. Mammoth water source heat pump faulty thermistor.

    I need information on a kind of thermistor NTC or PTC and its working resistance. Heat pump model # MSR016MGC21-BL, with Mitsubishi electric compressor model #RS233VRDC in it. Sensor attached to...
  9. Replies
    33
    Views
    5,487

    I think the use of suction driers depends on...

    I think the use of suction driers depends on numerous things. If there is a severe comp burn out, rather yes. If in the case of compressor mechanical problem rather no.
  10. Separate thanks to crazzycajun for vewing Tab...

    Separate thanks to crazzycajun for vewing Tab Journal! Never seen before!
  11. Thanks a lot hvacker! I have got no NEEB in my...

    Thanks a lot hvacker! I have got no NEEB in my 200 000 words dictionary! But I was kindly presented with ASHRAE book by our Trane guest in far 1998 in Moscow.
  12. Please do not abreviate! I am not professional...

    Please do not abreviate! I am not professional member nor native american! And I do not mean may be.
  13. A retrofit from water cooled condenser to air cooled.

    A retrofit from water cooled condenser to air cooled needed. The AC is Close Control RC Group unit with R22 scroll Copeland ZR40 (35 000 Btu) on board. The 1 issue is heat capasity of air condenser....