  1. I don't purge the grease out of the bottom port....

    I don't purge the grease out of the bottom port. I do however add 2 pumps or so and leave the bottom port open to relieve any excess pressure that may build up.. Thats one on the reasons the bottom...
  2. Replies
    13
    Views
    1,071

    Tighten it?:LOL: They are not compression. Its...

    Tighten it?:LOL: They are not compression. Its actually a hydraulic fitting.. Use some Nylog if you want. Ive never heard anyone else say theirs leak.
  3. Replies
    9
    Views
    249

    I wrote an email to the State about that...

    I wrote an email to the State about that checklist on their website. I was told the website does not update properly.. What else is new?:whistle: It shows it has not been looked at since June.
    I...
  4. Replies
    2
    Views
    157

    Why do you want to install one? Just because or...

    Why do you want to install one? Just because or is it seized and your just trying to get it going? If it the latter I would say its not working anyway so why not..
  5. Replies
    6
    Views
    441

    JCI and both honeywell use Niagara for a line of...

    JCI and both honeywell use Niagara for a line of their products.

    JCI= Facility Explorer

    Honeywell- Webs
  6. Replies
    5
    Views
    205

    HVAC69.. Thank you. I couldn't wait until...

    HVAC69.. Thank you. I couldn't wait until tomorrow... I hate it when that happens.. I was trying to link to alarm enable not inhibit.. Thats where I was having trouble. Thank you for you help.:cheers:
  7. Replies
    5
    Views
    205

    Ok that makes sense. I was thinking I needed...

    Ok that makes sense. I was thinking I needed something to translate the Enum Schedule. I never used a conversion before so this will be a learning experience for me.. Thank you and welcome to the...
  8. Replies
    5
    Views
    205

    Ill try this step by step tomorrow but when I hit...

    Ill try this step by step tomorrow but when I hit link mark from the alarm inhibit to the schedule everything in the schedule was not selectable except for changeover or whatever it was..
  9. Replies
    5
    Views
    205

    Tridium Alarms

    Ok guys I'm having a hard time setting up an Out of Range Alarm Extension..

    I want to look at an enumerated schedule and after 30 mins on occupied mode to generate an alarm if the zone sensor is...
  10. How could something large enough to make a...

    How could something large enough to make a compressor fail make it past the cap tubes?

    Also I think your theory is a little off.. Normally when you pump a system down you front seat the Liquid...
  11. Replies
    49
    Views
    1,389

    Could you do me a favor and tell the Idiots that...

    Could you do me a favor and tell the Idiots that run the state below yours that we have the right to the 2nd Amendment as well. It's known by many that only retired law enforcement are granted CCW's...
  12. Replies
    49
    Views
    1,389

    No legal CCW in Camden, NJ... Well not by us law...

    No legal CCW in Camden, NJ... Well not by us law abiding citizens anyway.. I hate working in that **** hole.. Good thing Im not there too often.

    Brian8383- your right there are a few things in...
  13. Replies
    10
    Views
    552

    I usually use an inline filter drier to the...

    I usually use an inline filter drier to the recovery machine to help with keeping the crap out of the system... Also i don't use it unless the system holds more the say 75 to 100lbs of gas..
  14. Replies
    10
    Views
    552

    Wait a minute.. Are you saying the compressor was...

    Wait a minute.. Are you saying the compressor was running while he was pumping it in with his recovery machine?
  15. Replies
    10
    Views
    552

    No big deal. I have done it, and will do it again...

    No big deal. I have done it, and will do it again I'm sure. In the case of TEV replacements there is something that happened to them. IT may have been system debris or a mechanical failure. Either...
  16. Replies
    34
    Views
    5,578

    Now I heard this second hand, I have not tried...

    Now I heard this second hand, I have not tried it.
    I was told recently Grainger started different levels of pricing. If they give you a price you can tell them it's too high. Then they can take...
  17. Replies
    17
    Views
    714

    WHoa... This is new? What makes residential so...

    WHoa... This is new? What makes residential so much harder on equipment then another part of the trade. If I had to wager I would bet being in a 100* roof then then to a -10* freezer with...
  18. Replies
    24
    Views
    1,298

    Hey I gave him options :LOL: I like what I...

    Hey I gave him options :LOL:

    I like what I like. The bullseye is a good tool so far. I really like it.
  19. Replies
    24
    Views
    1,298

    yes you need a dedicated micron gauge. They ones...

    yes you need a dedicated micron gauge. They ones that are built into the manifolds cause quite a headache lately, not to mention the accuracy is subpar from the info I have gathered..

    I would...
  20. Polyester in work clothing and fire don't mix...

    Polyester in work clothing and fire don't mix well.. I stick with cotton but they look nice..
    Is the veto going to be ready by end of summer? Is the the one bigger then the TP series but smaller...
  21. Replies
    25
    Views
    1,300

    post a pic of your display.. I would like to see...

    post a pic of your display.. I would like to see what your talking about.
  22. Replies
    7
    Views
    484

    What Ultrasonic do you use?

    What Ultrasonic do you use?
  23. Replies
    7
    Views
    484

    call bacharach. a friend of mine sent his B in...

    call bacharach. a friend of mine sent his B in and they transformed it into a G! :LOL: Unless you need the detector and can't wait. I think it was cheaper in his case to go that route..
  24. Replies
    473
    Views
    43,606

    It's going to fluctuate just about all the time....

    It's going to fluctuate just about all the time. 1/4 psi is not much and you will see it on the display.
  25. Replies
    473
    Views
    43,606

    My 1250's are still going strong as well. I...

    My 1250's are still going strong as well. I bought them during that group buy however many years ago that was. I use them everyday just like the ak's.
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event