  1. Thread: Chimney Liner

    by BURL-REF
    Replies
    23
    Views
    1,076

    never seen a power vented water heater enter...

    never seen a power vented water heater enter chimney.
  2. Replies
    14
    Views
    782

    Sounds like you share a common wall. If so, try...

    Sounds like you share a common wall. If so, try this for a day or 2.
    Get some painters tape and cover up all electrical outlets / openings on that wall.

    Next, if you have an attic space,...
  3. Replies
    14
    Views
    782

    I just read this article. Maybe it applies to...

    I just read this article. Maybe it applies to you.

    " A California city has imposed a ban on smoking in residential homes.



    The city council in San Rafael, Calif., passed Assembly Bill...
  4. Replies
    15
    Views
    936

    Have a look at this video by Ultra Fin. You may...

    Have a look at this video by Ultra Fin. You may find there are not enough fin sections in your install. You need to get this straightened out quick and get that outdoor sensor working. Ask the...
  5. Replies
    1
    Views
    242

    I installed a 155 model, it has the primary loop...

    I installed a 155 model, it has the primary loop installed with the option to not use it via shut off valve.

    the 70 and 110 do not have this feature
  6. you should be checking them filters every 3 to 4...

    you should be checking them filters every 3 to 4 weeks. It only takes a few minutes
  7. Your chimney is now to big for just a water...

    Your chimney is now to big for just a water heater. Once you removed the furnace, in most states its required to line the chimney with a properly sized liner, whether its an interior or exterior...
  8. Replies
    3
    Views
    542

    board one Links to direct purchase sites aren't...

    board one
    Links to direct purchase sites aren't permitted here.
  9. Replies
    4
    Views
    621

    Best to get more estimates. Don't think you'll...

    Best to get more estimates. Don't think you'll even get 14 out of them air handlers,, especially with a piston. First Co has no ratings on their site. Trane and American Standard have an air handler...
  10. Replies
    10
    Views
    571

    I will do that in the future, thanks

    I will do that in the future, thanks
  11. Replies
    10
    Views
    571

    Thank you Bob , and rundawg for your input....

    Thank you Bob , and rundawg for your input. Rundawg, thanks for the email with the part numbers, your a great asset to the forum having all this info for the asking.

    I searched my 4 suppy houses...
  12. Replies
    10
    Views
    571

    It is an OE motor

    It is an OE motor
  13. Replies
    10
    Views
    571

    Arco Aire AG036GB2 s# L982353770

    I'm looking for the specs on the dual capacitor for this unit. I changed the condenser motor on Saturday and found the dual cap was 45/5 @ 370v.
    Problem is the old fan and new fan state 3 mfd @...
  14. Have your tech use his scale for weighing in the...

    Have your tech use his scale for weighing in the r-22
  15. Replies
    12
    Views
    627

    I would pull the remaining Freon and start over....

    I would pull the remaining Freon and start over. Pressure test the complete system with nitro, and vac / recharge
  16. Replies
    11
    Views
    760

    I think he want s utilize the downflow and add...

    I think he want s utilize the downflow and add more duct to the side outlet.
  17. Replies
    6
    Views
    654

    http://www.pexsupply.com/Bell-Gossett-Hydronic-BPX...

    http://www.pexsupply.com/Bell-Gossett-Hydronic-BPX-Brazed-Plate-Heat-Exchanger-With-Mounting-Tabs-1694000
  18. Replies
    17
    Views
    1,609

    How about insulating that steam pipe

    How about insulating that steam pipe
  19. Replies
    9
    Views
    1,809

    Your lines in the wall would enter from the left...

    Your lines in the wall would enter from the left side and you can get at the connections by holding the bottom out off the wall. The back plate shows where to enter and has marks to determine the...
  20. Replies
    7
    Views
    1,306

    Under the house ?

    Under the house ?
  21. Replies
    7
    Views
    1,105

    I buy at about 20% less than acwholesales offer.

    I buy at about 20% less than acwholesales offer.
  22. Mark. these thermostats are called type 2, there...

    Mark. these thermostats are called type 2, there is no deadband on them, they either make r&w or r&y. There is no in between.
  23. Just so you dont waste time searching the web for...

    Just so you dont waste time searching the web for a new one, they mandated all mercury stats taken off the shelves , and not to be sold. Some company picks them up as they are hazardous waste.
  24. I just went through this with my customer. Oil...

    I just went through this with my customer. Oil burner tech offered 3 new t87 stats with new oil furnace. What a mess he had. Those stats are not available anywhere I looked. They are not your...
  25. One supply and 2 returns. Each return would need...

    One supply and 2 returns. Each return would need a purge / balance valve if any balancing needed to be done.