05-17-2005, 06:29 PM
Thread: Freezing suction line
by electrotech- Replies
- 17
- Views
- 1,778
if there is a restriction in the suction line,...
if there is a restriction in the suction line, (kink, undersized, clogged filter-drier, etc.) it will cause a pressure and temp drop between the a.h. and cond. unit, this can lead to freezing of the...
-
07-21-2004, 08:36 PM
Thread: Household refrigerator differential
by electrotech- Replies
- 2
- Views
- 596
most refridgerator cold controls are set around a...
most refridgerator cold controls are set around a 4 - 6* differential, so yours is just about inline. this amount of differential is needed, to prevent short cycling of the compressor, since many...
-
07-16-2004, 05:40 AM
Thread: trane condensing unit
by electrotech- Replies
- 14
- Views
- 1,990
someone before you probably grossly overcharged...
someone before you probably grossly overcharged the system, maybe because they knew it had a leak and didn't want to take the time to fix it. at an ambient of 72, the head pressure should be around...