Search:

Type: Posts; User: joeyd

Page 1 of 6 1 2 3 4

Search: Search took 0.02 seconds.

  1. Thread: Blu-vac problem

    by joeyd
    Replies
    7
    Views
    346

    Hi, ibenek. Our office hours are Mon. thru...

    Hi, ibenek.

    Our office hours are Mon. thru Fri. 9:00 AM to 5:30 PM.

    Call me today and I'll help resolve your issue.
  2. Replies
    98
    Views
    13,530

    On their way back today.

    On their way back today.
  3. Replies
    13
    Views
    786

    The BluVac technology is themistor based...

    The BluVac technology is themistor based technology with guaranteed operation down to 10F/-12C.
  4. Replies
    13
    Views
    786

    Even if.

    Even if.
  5. Replies
    13
    Views
    786

    3D, Please contact me and I'll arrange repair....

    3D,

    Please contact me and I'll arrange repair. Number is on the accutools.com website.
  6. Replies
    98
    Views
    13,530

    Call me. The number is at accutools.com.

    Call me. The number is at accutools.com.
  7. Replies
    98
    Views
    13,530

    Thomas, Clean the gauge with isopropyl as per...

    Thomas,

    Clean the gauge with isopropyl as per the manual. Be sure to dry the sensor (pull a vacuum on it with your pump for 30 seconds to a minute).

    Next, regardless of whether the oil...
  8. Replies
    98
    Views
    13,530

    Please see post 85...

    Please see post 85.
  9. Replies
    98
    Views
    13,530

    If you believe your BluVac -- or your vacuum...

    If you believe your BluVac -- or your vacuum setup -- is not working properly, call me at my office (phone # on www.accutools.com). I will help you work through the problem -- even if the problem is...
  10. Replies
    98
    Views
    13,530

    Call me in the morning. Number is on the website.

    Call me in the morning. Number is on the website.
  11. Replies
    98
    Views
    13,530

    It is a thermistor micron gauge. The sensor...

    It is a thermistor micron gauge. The sensor technology is new and patented.
  12. Replies
    54
    Views
    5,476

    I actually meant "remove the schrader", not the...

    I actually meant "remove the schrader", not the depressor.
  13. Replies
    54
    Views
    5,476

    I am not sure, but I think the presence of...

    I am not sure, but I think the presence of refrigerant is the likely answer. The Evac gauge (as well as nearly all electronic micron gauges) use gas thermal conductivity (TC) to indirectly measure...
  14. Replies
    54
    Views
    5,476

    I only just discovered this thread. Sorry for...

    I only just discovered this thread. Sorry for the delay. Is the OP's issue resolved? If not, how can I help?
  15. I support all my products -- regardless of the...

    I support all my products -- regardless of the label.
  16. Yup. I train GSDs as a hobby. Best all-around...

    Yup. I train GSDs as a hobby. Best all-around breed, IMHO...and mine is one of the best of the bunch. He scored the highest nationally in protection for his Schutzhund II title years ago.

    He'll...
  17. There is no 'licensing'. We manufacture eVacs...

    There is no 'licensing'. We manufacture eVacs right alongside BluVacs.
  18. Replies
    107
    Views
    10,248

    Sorry, I can't help you here. I'm an engineer,...

    Sorry, I can't help you here. I'm an engineer, not a field pro (and I have great respect for their skills and acquired knowledge). I know there are those on this forum that have their own...
  19. Replies
    107
    Views
    10,248

    Thanks for asking, Glenn! I come here to provide...

    Thanks for asking, Glenn! I come here to provide support for my products, not to promote them. But since you asked:

    The Evac Pro is a new product that incorporates ideas developed since the...
  20. Replies
    107
    Views
    10,248

    I do not know what you mean by "crystallized...

    I do not know what you mean by "crystallized screen".

    Regardless, if the unit had already been repaired once, I would have replaced it with a new one.
  21. Replies
    107
    Views
    10,248

    Well, it looks like a hard crash of our website...

    Well, it looks like a hard crash of our website -- seems update related. It won't be fixed today...so I just put up our "old" website for the time being. Sorry for the inconvenience!
  22. Replies
    107
    Views
    10,248

    Thanks, atnc.

    Thanks, atnc.
  23. Replies
    107
    Views
    10,248

    Aaarrg! Thanks for the heads up...it seems to...

    Aaarrg! Thanks for the heads up...it seems to have gone down this weekend. Now...how to find tech support on Sunday afternoon...
  24. Replies
    107
    Views
    10,248

    A while back we had some bad (contaminated)...

    A while back we had some bad (contaminated) connectors come from one of our vendors. This likely caused the problems you were seeing. I am sorry for your experience. We have, long ago, implemented...
  25. Replies
    19
    Views
    1,038

    It would be impossible to build a product of...

    It would be impossible to build a product of significant complexity today with all components sourced in the USA. For one thing, many components are not even manufactured in the USA, at any price. ...
  26. Replies
    19
    Views
    1,038

    Just for clarification, these are built in the...

    Just for clarification, these are built in the USA.
  27. Replies
    49
    Views
    5,931

    I have not had a BluVac returned that was damaged...

    I have not had a BluVac returned that was damaged by the use of Nylog. My only concern is that I found it does not dissolve in isopropyl alcohol. Therefore, if a vacuum gauge sensor did become...
  28. Mofotech, If you have any problems with it, let...

    Mofotech, If you have any problems with it, let me know.
  29. Thread: bluvac

    by joeyd
    Replies
    20
    Views
    1,864

    I'll be in the office tomorrow. Call me & I'll...

    I'll be in the office tomorrow. Call me & I'll get you fixed up. The number is on the accutools.com website.
  30. Replies
    6
    Views
    756

    Remember, danielthechskid, the BluVac/Evac II's...

    Remember, danielthechskid, the BluVac/Evac II's accuracy is spec'd as +/- (5% + 5 microns). Assuming your eVac II is working properly, a zero on the display can mean any pressure up to 5 microns.
    ...
  31. I generally don't comment, positive or negative,...

    I generally don't comment, positive or negative, wrt other companies' products. I am sure there are others here who would be willing to offer an opinion.



    I invented the Heated Pentode...
  32. Evac I & II, yes. Accuprobe, no.

    Evac I & II, yes. Accuprobe, no.
  33. Replies
    107
    Views
    10,248

    I'd be happy to repair or replace them, as...

    I'd be happy to repair or replace them, as necessary, if you drop them in the mail to me. Contact me (number is on the Accutools.com website) to arrange it.
  34. Replies
    35
    Views
    3,166

    The H10PM was the reference design I compared...

    The H10PM was the reference design I compared against while developing the ZX-1 many, many years ago. The original ZX-1's were at least as good, if not better than, the H10. TIF may have lost some...
  35. Replies
    107
    Views
    10,248

    Thanks, Greg. Social networking is a...

    Thanks, Greg.

    Social networking is a double-edged sword. Sometimes I feel like I'm airing my dirty laundry in public, but it's worth it. Getting up-to-the-minute feedback helps greatly to...
  36. Replies
    107
    Views
    10,248

    Let me know. I'll fix 'em for ya...

    Let me know. I'll fix 'em for ya...
  37. Replies
    47
    Views
    8,979

    Yes. Include your name, return shipping address,...

    Yes. Include your name, return shipping address, phone number, and email address, please.
  38. Replies
    47
    Views
    8,979

    I am sorry you are disappointed in our scale,...

    I am sorry you are disappointed in our scale, Anthony. The DS-220R has a great track record going back to 2005. I've got 20 to 30 thousand of them in the field and get back, maybe 1 per month for...
  39. Thread: Bluvac

    by joeyd
    Replies
    27
    Views
    3,238

    Never tested it. We recommend isopropyl...

    Never tested it. We recommend isopropyl (rubbing) alcohol.
  40. Thread: Bluvac

    by joeyd
    Replies
    27
    Views
    3,238

    A customer called me, insisting that his BluVac...

    A customer called me, insisting that his BluVac would always read Hi-P, even under a confirmed vacuum. I spent a half hour on the phone trying to work out the problem. No matter what we tried, the...
  41. Thread: Bluvac

    by joeyd
    Replies
    27
    Views
    3,238

    Anything from 70% to anhydrous will work fine.

    Anything from 70% to anhydrous will work fine.
  42. Thread: Bluvac

    by joeyd
    Replies
    27
    Views
    3,238

    No! For the simple reason that I have not tested...

    No! For the simple reason that I have not tested any solvent except for isopropyl (rubbing) alcohol for cleaning -- and alcohol works 100% of the time.

    Here is the procedure that I use here at...
  43. Thread: Bluvac

    by joeyd
    Replies
    27
    Views
    3,238

    Hey, Guys. Sorry I did not check in this weekend...

    Hey, Guys. Sorry I did not check in this weekend -- it's back to school today and we had a bunch of stuff to do to get my 7 y.o ready (in addition to the last pool party of the summer for her and...
  44. Replies
    9
    Views
    1,674

    IIRC, the 9010A requires an exactly 25.000kg...

    IIRC, the 9010A requires an exactly 25.000kg reference weight to calibrate. The procedure is something like this:

    1. Unload the platform.
    2. Turn the power on.
    3. Quickly press the units key at...
  45. Replies
    50
    Views
    5,819

    I'm a phone call away if you need any help...

    I'm a phone call away if you need any help...
  46. Replies
    50
    Views
    5,819

    It is my impression that TruTech has stock on...

    It is my impression that TruTech has stock on both BluVacs and LTEs. I am checking to make sure.

    FYI, I will support any BluVac gauge, whether it be Accutools, Y/J, or UEI.
  47. Replies
    22
    Views
    1,978

    If you suspect there may be an issue with your...

    If you suspect there may be an issue with your BluVac, give me a call and I'll try to help you. The number is on the Accutools.com website.
  48. Replies
    98
    Views
    13,530

    Please see this post...

    Please see this post. If you believe the motion is excessive, or if you notice unstable readings, contact me and I will repair it for you.
  49. Replies
    98
    Views
    13,530

    Your gauge is not operating correctly. Please...

    Your gauge is not operating correctly. Please contact me (contact info is at Accutools.com) and I will help you to resolve the problem.
  50. Replies
    98
    Views
    13,530

    I am glad you got a replacement quickly. Was...

    I am glad you got a replacement quickly. Was that through me or TruTech?

    In any case, if you have any further problems, please feel free to contact me directly.
Results 1 to 50 of 285
Page 1 of 6 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Quality Home Comfort Awards