  1. Replies
    4
    Views
    408

    This particular unit is 1990! Hard to stop a...

    This particular unit is 1990! Hard to stop a Trane. Yes, most of the units have been replaced. I'm down by the Everglades and it is very common for individual condos to have separate condensing...
  2. Replies
    4
    Views
    408

    High Rise Charging

    I'm not sure if this should be residential, but here goes. 20 story building, 3rd floor unit, separate condenser units for each condo on the roof. What is the correct way to charge, or to check...
  3. Replies
    3
    Views
    499

    Sir, As for used equipment, If you are buying a...

    Sir, As for used equipment, If you are buying a lighter gauge machine inspect it carefully as the previous owners will without fail try to bend heavier gauge sheetmetal and tweak it. Unfortunately...
  4. Replies
    4
    Views
    469

    Thanks to all! 1.) The unit is a Bard horizontal...

    Thanks to all!
    1.) The unit is a Bard horizontal package unit and is 8 years old - PA13361-A.
    2.) There is no 'board' on this old guy. Inputs from the t/stat (mercury) go back directly to the ECM...
  5. Replies
    4
    Views
    469

    ECM Amp Reading

    Say I take an amp reading on the hi-voltage leads of the 5 pin connector on an ECM motor. Is this the correct way to amp these motors out? My problem is I installed a factory OEM motor and I can...
  6. Replies
    8
    Views
    555

    The unit calls for 230 VAC - it is a single phase...

    The unit calls for 230 VAC - it is a single phase unit. The voltage is what it is - the mobile home park is about a half mile from a sub station - but it shouldn't be a reason for 250 VAC supply. The...
  7. Replies
    8
    Views
    555

    The incoming voltage drops to 245 VAC - the...

    The incoming voltage drops to 245 VAC - the control voltage drops to 27 VAC when unit is running.
  8. Replies
    8
    Views
    555

    Repititive time delay failures

    I installed a 13 Seer Rheem Achiever package unit. A call back found a froze up coil due to a faulty fan delay on off-relay - 4 weeks old. ( The indoor blower pulls in immediately and then runs 50...
  9. Replies
    186
    Views
    11,044

    Higher SEER have less latent removal

    Can any of you young guns explain this to me. In the Aug. 11th issue of HVAC The News - "Homes will continue to be built and remodeled tighter .... This will drive HVAC manufacturers to develop...
  10. Replies
    4
    Views
    669

    Thanks! The little stinker I looked at was...

    Thanks! The little stinker I looked at was available in different voltages. I have no idea how much usable light it really puts out, tho. It was a magnetic mount fits all sold at my local Rheem...
  11. Replies
    4
    Views
    669

    UV Light Install

    I've been out of the loop for awhile - so I don't know if this should be in the IAQ area. When installing a 24 VAC UV light "system" should you run a separate fused low voltage transformer or just...
  12. Replies
    0
    Views
    455

    Liquidtite and Fittings

    Spring and installs are around the corner! The following is available: 42' of 1/2" metallic; 35' of 3/4" metallic; 28' of 3/4" plastic (no ground); 20' of 1" metallic. Plus 59 fittings - not home...
  13. Replies
    1
    Views
    5,463

    GE TecMate Pro XL ECM Motor Tester

    Plug in tester for GE/RBC ECM motors. Johnstone S58-935 or Mars 08500. New in box - Never used. I'll search around for the directions, but you can easily down load them. Illness forces sale. $30.00...