    If it states unreliable as opposed to offline it...

    If it states unreliable as opposed to offline it is communicating. Did you auto discover the points? Are the values being displayed? If so check the min and max value with the analog objects to see...
  2. Replies
    20
    Views
    1,891

    Interesting how the "JCI engineer" states nothing...

    Interesting how the "JCI engineer" states nothing special needs to be done however you then go on to explain exactly what I stated. The statement is correct as changing the default value is not...
  3. Replies
    20
    Views
    1,891

    Stating the NAEs are by default Bacnet enabled is...

    Stating the NAEs are by default Bacnet enabled is incorrect. The site must specifically enabled for Bacnet and more than likely this is your issue. Go into the "all items" tab and double click on...
  4. Replies
    16
    Views
    1,567

    I agree with 98% of what you have stated. ...

    I agree with 98% of what you have stated. Including above. The issue I have is the main reason for abbreviating is for the installers benefit and not the customer.

    As for the raise in...
  5. Replies
    16
    Views
    1,567

    Y Nt Aws Abrvt Hhnvr u Wrt? I have been in the...

    Y Nt Aws Abrvt Hhnvr u Wrt? I have been in the trade for over 20 years and if I go to a site where someone else has configured the site using abbreviations I have to sometimes stop and decipher...
  6. Replies
    16
    Views
    1,567

    What antiquated system are you all using? Most...

    What antiquated system are you all using? Most devices in the last 10 years have enough character spaces to not need to abbreviate. Why not simply put Supply Air Temperature as opposed to SAT? ...
  7. I have run into the exact issue. Do not map the...

    I have run into the exact issue. Do not map the controller in as a FEC device. Map it in as a 3rd party device and it will function fine. It was claimed that the FEC were bacnet on steroids and I...
  8. Replies
    7
    Views
    945

    The NAEs can coexist at different versions with a...

    The NAEs can coexist at different versions with a few limitations. As stated if the new NAE is a 55 and a -2 like “MS-NAE5510-2” it can not be downgraded below probably 5.2. You will need SCT 5.2...
  9. Replies
    12
    Views
    1,875

    I agree with HVAC Mechanic Your static...

    I agree with HVAC Mechanic

    Your static pressure sensor does not "consume" any air volume per sea unless you are using a hot wire type. A 5/16 line 1000' long will possible have a delay of a...
  10. Replies
    10
    Views
    2,125

    The software is Free

    Sorry the link did not work. Here are directions to find it on the site for free. Go to Mcquay.com Then click on the following products>controls>Microtech II Controls>Application Software Last One...
  11. Replies
    10
    Views
    2,125

    Here you go

    If it looks like a Johnson Controls N30 with about 2 inches added all the way around this is what you will need. The software conflicts with Project Builder for N30s if you have it on the same...
  12. Replies
    1
    Views
    501

    I would think most front ends would be able to...

    I would think most front ends would be able to limit this. In PCT double click on “ZN-T Setpoint Determination” click “edit” and change the Min Cooling setpoint and Max Cooling Setpoint same with...
  13. Replies
    4
    Views
    1,868

    Easier Route

    Why bother with LCT with such a simple piece of logic? Just use an interlock if you are new to MSEA world. It will be a lot more self explanatory.
  14. Replies
    6
    Views
    672

    You can not setup a companion to communicate with...

    You can not setup a companion to communicate with a VMA.
  15. Replies
    3
    Views
    1,086

    i just installed PCT 5.3 on a machine that had...

    i just installed PCT 5.3 on a machine that had CCT 5.1 and niether one would function. I uninstalled CCT and reinstalled PCT and it is functioning. I did not have any problem with the Metasys BTCVT...
  16. DaveCR is correct as about the only way to be...

    DaveCR is correct as about the only way to be able to change the setpoint from the front end and still allow the occupant the ability to change the setpoint afterwards. It still boggles the mind...
  17. Replies
    6
    Views
    1,478

    Make sure the network setup in the NAE has the...

    Make sure the network setup in the NAE has the correct router ip address. This will not matter most of the time until accessing it from outside of the router. Some ISP block port 80 so that may be...
  18. Replies
    28
    Views
    2,919

    As far as trashing JCI for not being able to...

    As far as trashing JCI for not being able to upgrade an NAE 55 or 45 -0 past 4.08 keep this in mind. Can you put windows 7 on an old 386 Compaq computer? Does Compaq suck because of this? In all...
  19. Replies
    19
    Views
    2,601

    LCT issue

    You can not use LCT as it does not have a "release" function. Once again JCI missed something important. Simply insert an interlock. They are simple to use and pretty self explanatory. You will...
  20. Replies
    6
    Views
    1,406

    don't bother

    I have never been able to get a windows xp machine to download a zone terminal. The last time i needed to do this i purchased a windows 98 notebook for about $30 on ebay. My time beating my head...
  21. Replies
    2
    Views
    935

    RS-485 Unit Load Johnson Controls FEC

    Does anyone know where to find the "Unit Load" of not only Johnson FEC controllers but other manufactures as well? Is there a way to measure it with a meter? Is there any software that may be able...
  22. Replies
    12
    Views
    1,500

    First off different version of supervisor devices...

    First off different version of supervisor devices and servers will work fine with very small issues. With that said i have recently been told that the archive UPGRADE utility will in fact downgrade....
  23. Replies
    27
    Views
    4,747

    The fact you got the response from the...

    The fact you got the response from the webstats.info page this confirms the device is functioning properly and you are able to communicate with it. Go to security settings in IE and set them to low....
  24. Replies
    27
    Views
    4,747

    The "small" nae and nce running windows CE have a...

    The "small" nae and nce running windows CE have a simple web page that is usefull to try without getting Java involved. you would use http://xxx.xxx.xxx.xxx/webstats.info if you can get this page...
  25. Replies
    11
    Views
    930

    I have seen many fall victim to this scenario. ...

    I have seen many fall victim to this scenario. Take the small cover or display off and look on the board for a blue button. Push and hold for a couple of seconds with the power on. If all goes...
  26. Replies
    3
    Views
    1,057

    I am in south Florida and have set up static...

    I am in south Florida and have set up static reset, supply air reset and chilled water reset on the same building. All three strategies worked great. Even on the hottest days something would be...
  27. Replies
    6
    Views
    1,286

    there must be a network card installed

    The main control board will need a network card installed. It is cheaper to get the network card for a N30 and install it than getting it from Mcquay. You then have to configure the ip address and...
  28. Replies
    20
    Views
    1,469

    On your AO2 set it to 0=14MA and 100=7ma. Then...

    On your AO2 set it to 0=14MA and 100=7ma. Then set your sideloop to send the AO to 100%(7ma) when BI4 is on and when it is off the AO will be at 0%(14ma)
  29. Replies
    14
    Views
    2,066

    Once loged into the interface go to the "All...

    Once loged into the interface go to the "All Items" tab. Double click on the first thing in the list it is a building. Click the "Edit" button and the advanced selection and scoll down to the...
  30. Replies
    20
    Views
    1,469

    Simple

    If your output is set to 0-10V change it to 2-10V or whatever you want your lowest voltage to be. Then setup your sideloop to do the higher voltage when the BI is on.
  31. Replies
    4
    Views
    554

    For converting hex to decimal simply use windows...

    For converting hex to decimal simply use windows calculator. Open calculator and select view and change it to scientific. Decimal is the default so type in the decimal value and then click Hex....