    Field controls makes a combustion air intake kit...

    Field controls makes a combustion air intake kit called a fan in a can.. they work great. It will add a motor and potential repair costs down the road but it has an interlock switch to ensure the air...
  2. Yank the motor and a little diluted calclean HD...

    Yank the motor and a little diluted calclean HD and good as new
  3. Replies
    1
    Views
    155

    I scanned one on a Rheem and was depressed to see...

    I scanned one on a Rheem and was depressed to see a parts section.. seriously? We install your product and you pimp others???? It was a whole Lotta nothin...
  4. Replies
    11
    Views
    332

    I would check out arzel... disclaimer that I have...

    I would check out arzel... disclaimer that I have never used Jackson as I have never seen a need to
  5. If the space Is wide open it would be fine with 1...

    If the space Is wide open it would be fine with 1 head
  6. Easily Sent from my iPhone using Tapatalk

    Easily


    Sent from my iPhone using Tapatalk
  7. Adams is a horror show. Thermopride just came out...

    Adams is a horror show. Thermopride just came out with a condesing oil.. haven't seen one in person but love the company.
  8. Replies
    7
    Views
    467

    I live 30 miles east and got 38", no good...

    I live 30 miles east and got 38", no good stories. My 4wd on my plow truck took a dump that day...


    Sent from my iPhone using Tapatalk
  9. Replies
    35
    Views
    2,315

    Could easily sleeve the control wire in 3/8 Vinal...

    Could easily sleeve the control wire in 3/8 Vinal tubing


    Sent from my iPhone using Tapatalk
  10. Replies
    3
    Views
    1,429

    Around here, an oil filter is never installed...

    Around here, an oil filter is never installed outdoors. I prefer. Tiger loop ultra


    Sent from my iPhone using Tapatalk
  11. The home has a tag depicting the heat loss at a...

    The home has a tag depicting the heat loss at a given temperature. It would be located by your electrical panel or in some cases in the master closet


    Sent from my iPhone using Tapatalk
  12. I would go with the 8523 though. The rubber boot...

    I would go with the 8523 though. The rubber boot is great as it is magnetic. Just slap it on the side of the unit. The hard case will help if it gets banged around in the van


    Sent from my iPhone...
  13. Field replaceable "b-smart" sensors. They send...

    Field replaceable "b-smart" sensors. They send you a new sensor and you return the old in a package they send you


    Sent from my iPhone using Tapatalk
  14. I have ordered and have about 15 of them in the...

    I have ordered and have about 15 of them in the field. (ordered 2 from ttt yesterday). They are good units but it seems the oxygen sensors are prone to dying pretty quick. I have had 3 fail within a...
  15. Replies
    15
    Views
    585

    Could go with (2) 600's? Sent from my iPhone...

    Could go with (2) 600's?


    Sent from my iPhone using Tapatalk
  16. Replies
    30
    Views
    6,322

    I ordered a dozen from my local vendor. Part...

    I ordered a dozen from my local vendor. Part number in the link.
    http://herchem.net/specs/UnPurple.pdf


    Sent from my iPhone using Tapatalk
  17. Love it! Sent from my iPhone using Tapatalk

    Love it!


    Sent from my iPhone using Tapatalk
  18. Replies
    28
    Views
    1,573

    I am going to follow this thread. I have seen...

    I am going to follow this thread. I have seen numerous goodman Gmh with co In the 200-300. I spend many many hours Testing one from orifice sizing, clocking the meter, delta. T , venting to come to...
  19. Replies
    16
    Views
    989

    You will get many manufacturer opinions but my...

    You will get many manufacturer opinions but my vote would be the sdmn5 which is the same as the unit that tests pressure switches but this one does not. For around $120 I think it would be a great...
  20. Stay safe man Sent from my iPhone using...

    Stay safe man


    Sent from my iPhone using Tapatalk
  21. Replies
    12
    Views
    471

    I see an upgrade kit in your future Sent...

    I see an upgrade kit in your future


    Sent from my iPhone using Tapatalk
  22. Replies
    3
    Views
    352

    Your blower should be set to 350-400 cfm per ton...

    Your blower should be set to 350-400 cfm per ton with a properly charged system. The rest falls where it may


    Sent from my iPhone using Tapatalk
  23. Replies
    13
    Views
    700

    Keep calling around. You can also check...

    Keep calling around. You can also check Mitsubishi site for a diamond dealer as they should be likely experienced. I cleaned 3 of them last week at a house in 1:15. It does require some removal of...
  24. Replies
    16
    Views
    954

    I need a fitting

    Try this?
    http://orders.sidharvey.com/IMAGES/catalog/Unpriced/201013-14.pdf


    I use this
    http://orders.sidharvey.com/product/T34/P115-10


    Sent from my iPhone using Tapatalk
  25. Replies
    13
    Views
    846

    Both were in operation. We were replacing both of...

    Both were in operation. We were replacing both of them.


    Sent from my iPhone using Tapatalk
  26. Replies
    13
    Views
    846

    516301 At a house with 2 iron fireman and...

    516301

    At a house with 2 iron fireman and thought of this post.


    Sent from my iPhone using Tapatalk
  27. Replies
    20
    Views
    1,035

    Love it firecontrol Sent from my iPhone...

    Love it firecontrol


    Sent from my iPhone using Tapatalk
  28. Money says that heat exchanger is cracked! ...

    Money says that heat exchanger is cracked!


    Sent from my iPhone using Tapatalk
  29. Replies
    20
    Views
    1,035

    Boiler Quotes

    Well,, it depends on the design temperature of your baseboard to make an educated decision IMO. If you will be operating near 180 degrees then the efficiency will be in the high 80s to low 90s during...
  30. Replies
    4
    Views
    526

    Honeywell spark ignition kit with a new pilot...

    Honeywell spark ignition kit with a new pilot assembly


    Sent from my iPhone using Tapatalk
  31. Thread: Hole saw

    by kangaroogod
    Replies
    5
    Views
    590

    Hole saw

    What does everyone use for cutting/boring 3-5/8" holes through sill plates? Around here it is not uncommon to have 12" railroad ties and spending several hours on holes is a real drag. Standard hole...
  32. We had a dozen or so in use, almost as accurate...

    We had a dozen or so in use, almost as accurate as my analog needle on my gauges. I think all of them are in micron gauge heaven. Bluvac and move on with life :)


    Sent from my iPhone using...
  33. Whole house ventilation and dehumidifier

    At 400 cfm +\- and depending on the footprint, I would run (2) oversized ducts up and (2) oversized ducts down which will allow you manual control to close a particular floor if needed. Return each...
  34. Replies
    2
    Views
    278

    The question comes down to what is wrong with the...

    The question comes down to what is wrong with the ac? Ice ball typically is an airflow issue or a leak in the refrigeration system. If the system is leaking at that age, IMO you are best to look at...
  35. Replies
    10
    Views
    744

    I had 2 of mine break and a few other guys had...

    I had 2 of mine break and a few other guys had the same a couple yrs ago. The replacements seem to hold up better. And the "call me" was suppose to be "call em" :)


    Sent from my iPhone using...
  36. Replies
    10
    Views
    744

    They do that,, been told it was a "bad batch" and...

    They do that,, been told it was a "bad batch" and the plastic has changed. Call me and they will send ya new ones


    Sent from my iPhone using Tapatalk
  37. Replies
    16
    Views
    2,096

    Not me,,, like dating a woman that has been...

    Not me,,, like dating a woman that has been around the block too many times.


    Sent from my iPhone using Tapatalk
  38. Replies
    29
    Views
    1,670

    Venting a Gas Furnace

    Another option would be to (2) pipe the furnace up the abandoned chimney chase allowing for a 2 pipe system and installing an electric water heater to replace the gas one. Using electric to heat...
  39. Condensing boilers with single pipe vs two pipe loops

    Without replacing or adding a large amount of additional radiation you have a condensing boiler that will not condense in most situations. Your best chance is having an outdoor reset control...
  40. Replies
    4
    Views
    331

    Maybe the liner is kinked/plugged and the unit is...

    Maybe the liner is kinked/plugged and the unit is not venting properly and condensing? Maybe the gas pressure/rise is off? Maybe the connector in inadequate? Perhaps the termination is too short?
  41. Replies
    17
    Views
    955

    Propane line from tank

    I deal with this quite often. The propane supplier will provide us with a regulator at the entrance of the home Outside, we take it from there. In my experience they instal the piping wicked cheap....
  42. Replies
    0
    Views
    253

    Jb dv200 vac pump issue

    Anyone ever have the ballast knob break on a pump? I have never seen this and I had 2 guys break the bolt part internal in the threading this week. Both pumps less than 2yrs old. At first I thought...
  43. Replies
    26
    Views
    3,671

    I sliced my tendons on 2 fingers on rheem 80%...

    I sliced my tendons on 2 fingers on rheem 80% about 12yrs ago. I was in a cast for 4 weeks Rheem could care less. The bottom blower door edge. Another guy I worked with is almost the identical thing...
  44. Replies
    1
    Views
    322

    Looking up the specs, it says "do not install in...

    Looking up the specs, it says "do not install in location that is hot or humid for long periods of time".
  45. The condensate pump is used when you do not have...

    The condensate pump is used when you do not have a gravity drain meaning that you cannot go down maintaining pitch. The example you describe would be a wall unit installed on an interior wall with...
  46. Replies
    9
    Views
    559

    I wouldn't worry about the bent line. It is not...

    I wouldn't worry about the bent line. It is not going to effect operation of any measurable difference. Kinda looks Undesirable as the unit is not centered on the pad.
  47. Replies
    19
    Views
    4,340

    Look at all the white cellulose

    Look at all the white cellulose
  48. Replies
    14
    Views
    1,321

    Well the 460 is out. Doesn't seem to be much info...

    Well the 460 is out. Doesn't seem to be much info regarding wireless or future app compatibility??? It isn't listed on the fieldpiece site. Ttt and others have them. I'll stay tuned I suppose
  49. Your contractor can hook you up. ...

    Your contractor can hook you up.

    https://www.taco-hvac.com/archives/100-3.4G.pdf
  50. Some like ford, some like Chevy. I personally...

    Some like ford, some like Chevy. I personally like the taco as they have a vacuum breaker installed.
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine