Search:
Type: Posts; User: jjou812
Search: Search took 0.01 seconds.
-
01-01-2013, 11:09 AM
Thread: combustion analyser
by jjou812- Replies
- 124
- Views
- 14,674
Thanks. The pump came apart easily. I saw no...
Thanks. The pump came apart easily. I saw no dirt or any other problem with the diaphragm or reeds. I put it back together and now it works fine. I wonder what I did that fixed it.
... -
12-20-2012, 02:42 PM
Thread: combustion analyser
by jjou812- Replies
- 124
- Views
- 14,674
I took out the pump but couldn't figure out how...
I took out the pump but couldn't figure out how to get it apart without breaking it. Is there a way of squeezing it to separate the halves?
-
12-17-2012, 04:44 PM
Thread: combustion analyser
by jjou812- Replies
- 124
- Views
- 14,674
I read somewhere that the 320 is made in germany...
I read somewhere that the 320 is made in germany and the 310 is made in china. Can anyone confirm this? I am considering replacing my 5.5 year old TSI 6130.
Has anyone seen this problem on the... -
03-29-2010, 09:00 PM
Thread: yellow jacket ratcheting tube bender
by jjou812- Replies
- 9
- Views
- 1,780
I've been using that bender for years. It works...
I've been using that bender for years. It works great as long as I keep the shoes oiled. And yes I highly recommend the reverse attachment
-
10-17-2009, 07:03 PM
Thread: which is the better ERV
by jjou812- Replies
- 7
- Views
- 717
http://www.hvi.org/assets/pdfs/CPD/CPD_Sec3_01Oct0...
http://www.hvi.org/assets/pdfs/CPD/CPD_Sec3_01Oct09.pdf
Renewaire rates very well in these tests. -
10-16-2009, 07:57 AM
Thread: Re-Use XE78 furnace?
by jjou812- Replies
- 8
- Views
- 458
most power venters are not plug-and-play. they...
most power venters are not plug-and-play. they have a throttle that needs to be adjusted correctly or they will draw too much air through the heat exchanger. be safe and have a pro set it up.
-
10-15-2009, 08:02 PM
- Replies
- 13
- Views
- 747
why don't you want 95%?
why don't you want 95%?
-
10-15-2009, 11:08 AM
Thread: Hot Surface Ignitor lifespan
by jjou812- Replies
- 15
- Views
- 1,985
Rheem used 34 second ignitors. Most trucks are...
Rheem used 34 second ignitors. Most trucks are stocked with 17 second ignitors which are much more common and will burn out prematurely if heated for 34 seconds. The correct ignitor will say Protech...
-
10-10-2009, 11:22 PM
Thread: older trane system
by jjou812- Replies
- 3
- Views
- 416
control wiring for heat pumps is more complex...
control wiring for heat pumps is more complex than for typical furnaces and a/c. and it is not consistent among brands. the safe thing to do is hire an hvac guy to connect the systems.
-
10-10-2009, 11:14 PM
- Replies
- 24
- Views
- 922
don't let anyone dissuade you from doing...
don't let anyone dissuade you from doing research, seeking advice, and getting several bids. the guy who told you manual j calculates low is wrong. an outdoor tstat is a must. make sure the...
-
10-10-2009, 02:54 AM
Thread: Air Cleaners
by jjou812- Replies
- 7
- Views
- 505
all electronic air cleaners produce ozone which...
all electronic air cleaners produce ozone which is a pollutant. personally I prefer an extended media filter (examples: 20x25x5 merv 11, or SpaceGard)
-
10-10-2009, 02:37 AM
- Replies
- 9
- Views
- 1,113
To me 95% is all that exists. I almost never...
To me 95% is all that exists. I almost never install 80%.
Multistage is for comfort. For lowest gas usage, get a properly sized 95% single stage unit. -
10-10-2009, 02:09 AM
Thread: This may make you laugh!! But I'm not!!
by jjou812- Replies
- 18
- Views
- 847
Ways to close gaps in ducts: 1. Have...
Ways to close gaps in ducts:
1. Have correctly sized duct fabricated.
2. Use sheetmetal pieces/angles to close gap and seal with duct sealer.
Wrong way to close gaps : Tape.
Tape may be... -
10-10-2009, 01:59 AM
- Replies
- 36
- Views
- 4,814
That's too bad. Hallowell's idea seems on paper...
That's too bad. Hallowell's idea seems on paper to be a winner. I guess they need to work out the bugs.
-
10-07-2009, 09:28 PM
- Replies
- 41
- Views
- 2,356
http://www.renewaire.com/for_your_home/faq.php
http://www.renewaire.com/for_your_home/faq.php
-
10-07-2009, 02:01 AM
Thread: New Media Filter - Correct Size?
by jjou812- Replies
- 7
- Views
- 787
I use 20 x 25 x 5 MERV 11 filters made by...
I use 20 x 25 x 5 MERV 11 filters made by Ultravation. Reasonable pressure drop, good filtering, and change interval of every six months. That is a common size made by several other mfrs: Trion,...
-
10-07-2009, 01:36 AM
Thread: Fed up with service company and Trane
by jjou812- Replies
- 58
- Views
- 4,558
Are there any pool chemicals or water softener...
Are there any pool chemicals or water softener salt in the house? Chemicals in the air cause formicary corrosion which can kill a coil in one year.
On the other hand, I used to work for a... -
10-07-2009, 12:52 AM
Thread: I need a new meter
by jjou812- Replies
- 47
- Views
- 2,631
Fluke 116 and 179
Fluke 116 and 179
-
10-03-2009, 02:25 PM
Thread: Combustion Efficiency Analyzer
by jjou812- Replies
- 10
- Views
- 1,090
http://www.raeco.com/acatalog/TSI_CalibrationKits....
http://www.raeco.com/acatalog/TSI_CalibrationKits.html
Kit # 802003
Do you guys use such a kit? Is there a cheaper alternative? (I already have the nitrogen, so I just need the 500 ppm CO) -
10-02-2009, 11:59 AM
Thread: Combustion Efficiency Analyzer
by jjou812- Replies
- 10
- Views
- 1,090
I also have the 6130. The mfr wants it...
I also have the 6130. The mfr wants it calibrated at least once per year. The kit costs $600 !!!!!!!!!
I refuse to spend that much for a calibration kit, so I tolerated some inaccuracy for about... -
06-12-2009, 10:20 AM
- Replies
- 22
- Views
- 2,615
A 95% furnace is 95% efficient when running at...
A 95% furnace is 95% efficient when running at maximum capacity. When the furnace modulates down to a lower capacity for comfort, the efficiency goes down. Unfortunately for now, there are no...
-
06-12-2009, 09:48 AM
Thread: 13 year old Trane Air conditioner problem
by jjou812- Replies
- 8
- Views
- 1,452
just get a generic 1.5 ton coil with correct...
just get a generic 1.5 ton coil with correct piston size per outdoor unit
-
06-12-2009, 09:14 AM
Thread: VS fan or not !?
by jjou812- Replies
- 5
- Views
- 358
Reasons for VS: 1. You run fan continuously...
Reasons for VS:
1. You run fan continuously to reduce stratification.
2. You run fan continuously because you use extended media or electronic air filtration and want cleanest air.
3. Your... -
06-12-2009, 09:06 AM
- Replies
- 12
- Views
- 2,997
I've had this on occasion. The xformer vibrates...
I've had this on occasion. The xformer vibrates the sheetmetal it's attached to which vibrates against another piece of sheetmetal. Easy for tech to fix. Identify the source and shove something in...
-
06-08-2009, 10:11 PM
Thread: Problem with Sears Heat Pump.
by jjou812- Replies
- 15
- Views
- 1,094
most Kenmore units are made by ICP
most Kenmore units are made by ICP
Results 1 to 25 of 215