Search:

Type: Posts; User: CumulusMech

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Its a lennox knock off , I forgett the name ,...

    Its a lennox knock off , I forgett the name , Aire or something . I work on chillers .
    Its bessar because I repaired the Goodman before replacing it and it lasted two weeks if that . Also , I...
  2. The unit is sitting on An alluminum adjustable...

    The unit is sitting on An alluminum adjustable stand provided by lennox , Im sure you have seen them . It is also install beside the cottage away from the roof , which has evestough .
    An animal...
  3. Condensing unit rotting at bottom passes , just installed last year

    Hey guys , anyone know about what could cause a condensing unit to rot out on the bottom passes . A unit I installed at a cottage withj associated pine trees in the vacinity has done just that . The...
  4. Hi Rich . Thanks for responding . I must say I...

    Hi Rich . Thanks for responding . I must say I came off strong , but I do love my trade . The last company I worked for we had 5 apprentices who reported serious injuries . Also it is a well known...
  5. I am not suprised to hear this . Canada is...

    I am not suprised to hear this . Canada is structured compleatly differently . In my oppinion for the better . We have I believe , one of the highest standards in the world . One to one is...
  6. Three mechanics to 0ne apprentice , or one mechanic to one apprentice ratio

    I live in Ontario ,and the poltical num nuts in this province want one mechanic for one apprentice ratio . Currently it is three mechanics to one apprentice . I believe it is this way coast to coast...
  7. It sounds like you have too much cappacity ,...

    It sounds like you have too much cappacity , dropping sensible and not rh .
  8. Replies
    31
    Views
    2,040

    Shut the compressors off on disconnect and check...

    Shut the compressors off on disconnect and check suction for rapid increase in temperature . At least you can try to verify discharge valves .
    It realy sounds like your system is over loaded , or...
  9. Replies
    24
    Views
    2,135

    Ok , so the charge is good and the metering...

    Ok , so the charge is good and the metering device has been changed . Still you have low suction pressure . Clearly , the low suction pressure is due to a lack of heat exchange between the water...
  10. Replies
    3
    Views
    541

    Knee jerk reaction is low charge , but like...

    Knee jerk reaction is low charge , but like graham said , more info is needed .
  11. Flange ,LMAO , thats classic but to the point ....

    Flange ,LMAO , thats classic but to the point . Well done .
  12. Replies
    13
    Views
    3,056

    Run your chiller at 40 f . Make sure that the...

    Run your chiller at 40 f . Make sure that the evap temp does not go below 34 f . Not sure if this is possible , it all depends on how efficient the chiller is .
  13. Do you have access to natural gas ?

    Do you have access to natural gas ?
  14. Replies
    6
    Views
    842

    Johnson Controls has a tool called a Commisioning...

    Johnson Controls has a tool called a Commisioning Tool . It has every thing you need . Contact a local controls distributer that deals with JC .
  15. Replies
    13
    Views
    1,478

    Temperature swings ? Do you have an rh and...

    Temperature swings ?
    Do you have an rh and temperature recorder ?
    Is it possible that you have too much cooling in winter , not enough in summer ?
  16. Replies
    13
    Views
    1,478

    i don't think over kill is in your best interest...

    i don't think over kill is in your best interest . Nice project though . Yes , choose a system with economizers . Fresh air is your only combatant against co2 . But design it with comparative...
  17. [QUOTE=Slip Stream;6212702]How did that happen? ...

    [QUOTE=Slip Stream;6212702]How did that happen? Did the fan catch edge and rip itself off?[/QUOTE

    Is it possible that snow or ice built up on the fans . They look like they started up off...
  18. Replies
    65
    Views
    10,346

    recent goodman install

    Looks good . Hope the external equilizer line is installed after the TX valve bulb .
  19. Replies
    2
    Views
    1,241

    Anyone work for Cimco Refrigeration ?

    Just curious to know what its like to work for them . If anybody knows anything I would be interested to know .

    Thanks
  20. Replies
    374
    Views
    26,994

    Thanks FrueCrue , we must think like doctors and...

    Thanks FrueCrue , we must think like doctors and eliminate possibilities one step at a time . Good hunting .

    Peace
  21. That's a great question , but I have never ran...

    That's a great question , but I have never ran into an install with that app. , Sorry. I would be interested in this answer when you find out . Got any pics ? You obviously have no access to the...
  22. As a matter of fact I would . You have it all...

    As a matter of fact I would . You have it all wrong dilky . At least 700 miles south of the Mexican border . Cmon man??????
  23. Replies
    374
    Views
    26,994

    If it is possible , it would be very interesting...

    If it is possible , it would be very interesting to see the performance characteristics of the motor or motors at your local motor repair shop . Provide them with all the information you have , and...
  24. Replies
    11
    Views
    1,364

    Thats a very dangerous install . I hope your area...

    Thats a very dangerous install . I hope your area does not go below freezing .
  25. Replies
    5
    Views
    1,098

    One thing I thought to mention . I am...

    One thing I thought to mention .

    I am assuming that the system was working previously .
  26. Labour Unions

    I realise that this is of topic RoBoTeq ( and that's Cumulonimbus to you ) , but I was hoping that no one would agree with me . I , however , have unfortunately experience a not so rosy picture . I...
  27. Replies
    14
    Views
    1,098

    Hunter Stats

    Hunter Stats are garbage . People try and save a buck , but a cheape stat is just that , cheap junk . Nothing against saving money . Buy Honeywell , and not from Homedepot .
  28. Unions

    Unions make alot of sense because there is never any argument about wages . However , I have always found that union work environments are toxic work places . Anytime I have heard of a suicide , it...
  29. Replies
    26
    Views
    7,433

    Hey Boogie

    Dont be shy about getting several quotes . Anytime you rush into things you will get screwed . Get a heat load calc. done . Then choose the product .
  30. Replies
    42
    Views
    4,895

    Calling all Liebert exp

    Yes , in allot of cases I have found the oil levels too high causing damage to the gaskets or valves . Liquid refrigerant slugging as well of course . Check the compressor for valves and gaskets . A...
  31. Replies
    14
    Views
    3,017

    Central Electric Furnace help

    The bushings are finished in the motor or the fan bracket is broken due to an off balance blower wheel or all of the above . The motor is junk and make sure you install a new blower wheel . Change...