    I have much respect for the hvac techs...

    I have much respect for the hvac techs responsibilities and work ethic. Attics in the summer, calls in the middle of the night in the winter. Many of us will pay more for quality, especially if it...
  2. Replies
    4
    Views
    417

    No problem other than disappointment that it...

    No problem other than disappointment that it takes foreign manufacturers to introduce variable speed compressors, electronically controlled TXVs and associated control logic to mitigate the downsides...
  3. Replies
    4
    Views
    417

    Heat Pump Defrost Noise (continued)

    I thought I would reply to an older thread on defrost noise mitigation here, but the Admins would not let me. So I will comment on that thread now.

    The problem with professional local Texas...
  4. Actually the instructions on page 17 & 18 are a...

    Actually the instructions on page 17 & 18 are a typo corrected on page 26. The actual paper instructions correct that typo. Yes the Ritetemp 6022 was set for Electric heat rather than Gas Fuel.
    ...
  5. As a forum moderator on another site, I know it...

    As a forum moderator on another site, I know it takes patience to walk someone through a problem step by step. It takes time and desire to share knowledge and experience.

    As indicated, the...
  6. I agree reading the instructions pays dividends. ...

    I agree reading the instructions pays dividends. I did read both the Honeywell's and the RiteTemp's. Even called the Honeywell help line, who did try to help but did not come up with the answer...
  7. I installed the 1k 1w resistors on the Fan and...

    I installed the 1k 1w resistors on the Fan and Heat terminals to ground and found that either electronic thermostat would work now.

    Sorry if installing a thermostat is DIY. Perhaps Home Depot...
  8. Power Stealing Thermostat Fails / Mechanical Works

    Sorry if this is redundant to previous posts. I tried to replace a true mechanical AC / Electric Heat thermostat (no common wire) with a programmable one. It did not work.

    (edited for...
  9. Replies
    5
    Views
    401

    My heat pump does turn on the emergency heat on...

    My heat pump does turn on the emergency heat on failure. Problem was I won't know it most of the time. Now I can see the LED indicating the heat pump's down. By further logic I can assume the...
  10. Replies
    5
    Views
    401

    Vision Pro IAQ Emergency LED Operation?

    Ok, I now have the equipment failure LED functional on my Vision PRO IAQ with EIM system. That was connecting the York X/L to the EIM's L input. Doing so revealed the existence of the...
  11. Thanks. Don't want to replace the motors; not...

    Thanks. Don't want to replace the motors; not because of warranty as much as extended downtime while parts are shipped in.
  12. Replies
    2
    Views
    661

    Thanks,that was it. The EIM install manual had...

    Thanks,that was it. The EIM install manual had nothing in it about L even though it is labeled on the board. The installer got it working with your info:)
  13. Replies
    2
    Views
    661

    York XL Trouble Output to York IAQ Thermostat

    Is there any method to connect a York Heat Pump's X/L output (trouble status) to a Honeywell Vision Pro IAQ thermostat so that the user can see the trouble flashes? My 20 year old Lennox thermostat...
  14. Appreciate the quick response. Besides...

    Appreciate the quick response. Besides potentiallly running backwards, are there any previously identified issues that have happened with common return on two VS air handlers/heat pumps? Will the...
  15. Dual Heat Pumps w VS and common return Not Twinned

    I have dual York heat pumps, two VS air handlers with a common return. They are not twinned and they are not the same size (one is 3 ton the other 4 ton). Based on other posts, I see that the...
  16. Replies
    77
    Views
    45,952

    Move, seal or buy a new system (or a combination)

    Amazing this system keeps sending emails on old threads like this.

    As a person who has had two (2) replacement systems installed since your first post (in different houses), I feel for you. ...
  17. Replies
    66
    Views
    4,708

    Amazing how simple the answer is once you know it...

    Amazing how simple the answer is once you know it ;) . What's sad is that I had a similar problem with my IAQ (higher temp though) that I solved with silicon...
  18. Replies
    66
    Views
    4,708

    One last thought, it just doesn't make sense that...

    One last thought, it just doesn't make sense that you would have high humidity during the day and lower humidity at night, just the opposite of outside conditions. Since the overall system is...
  19. Replies
    66
    Views
    4,708

    My last house had a Carrier 2 stage VS with...

    My last house had a Carrier 2 stage VS with zoning and their built in humidity control. My current home has a York 2 stage VS with the Honeywell IAQ installed in Central Texas. Both provided...
  20. Thread: Frank Lloyd Wright

    by rjp
    Replies
    25
    Views
    1,638

    FLW "Skyscraper" in Bartlesville, Oklahoma was...

    FLW "Skyscraper" in Bartlesville, Oklahoma was interesting. It's now a hotel, museum and restaurant. Actually rather small spaces. But to be fair, I understand it is really a scaled down version...
  21. Replies
    6
    Views
    614

    Just replaced a 22 year old Lennox Heat Pump...

    Just replaced a 22 year old Lennox Heat Pump (originally 9.25 Seer) with a York Affinity 2 stage scroll, VS blower, 4" Honeywell Media Filter and Honeywell Visionpro IAQ. I now live in Canyon Lake,...
  22. Replies
    1
    Views
    549

    Recommend 2 stage R22 Scroll Heat Pump?

    Does anyone make a 2 stage R22 Scroll based heat pump? I know Trane has the xl19i recip 2 compressor unit in R22.

    Various manufacturers seem to have R22 Variable Speed Indoor Units.

    thanks
    ...
  23. Replies
    5
    Views
    584

    Need to relocate one of two thermostats that were...

    Need to relocate one of two thermostats that were originally installed together. Very difficult attic to run wires combined with 12ft interior walls full of insulation.
  24. Replies
    5
    Views
    584

    Any recommendations for a Wireless Thermostat for...

    Any recommendations for a Wireless Thermostat for a Heat Pump amplication with auxillary electric heat?

    I found the Honeywell T8665A and W8665E receiver but it appears to require a zoning...
  25. Glad you are finally close to perfect. My...

    Glad you are finally close to perfect. My Northern Oklahoma well contructed home needed a 5 ton 2 stage system with zoning to ensure even room temperatures throughout. Different rates of heat gain...