  1. Replies
    12
    Views
    288

    Yes both are new

    Yes both are new
  2. Replies
    12
    Views
    288

    I went ahead and by passed the dehumidifier....

    I went ahead and by passed the dehumidifier. Thinking it's bleeding back. So now I have straight pipe to condenser coil and straight line back from evap. Still the same issue. Ugh not having fun on...
  3. Replies
    12
    Views
    288

    It's the valve for the dehumidifier

    It's the valve for the dehumidifier
  4. Replies
    12
    Views
    288

    Bard 3.5 ton wall hung

    I posted before on this system. I replaced the cap tube assembly and txv. Weighed in the charge. I'm getting no SH. sub cool is 15. And I'm only getting a 10 degree split. I'm stumped. I'm back to...
  5. Thread: Bard wall hung

    by biggi
    Replies
    4
    Views
    248

    Do they make a replacement cap tube assembly for...

    Do they make a replacement cap tube assembly for those. I've built them before for other commercial units but didn't know they made them.
  6. Thread: Bard wall hung

    by biggi
    Replies
    4
    Views
    248

    Hit wrong button lol. Anyways. I seen 3 of the 5...

    Hit wrong button lol. Anyways. I seen 3 of the 5 caps tubes sweating 2 not sweating.
  7. Thread: Bard wall hung

    by biggi
    Replies
    4
    Views
    248

    Bard wall hung

    Ok guys here's one for you. Got a bard wall hung not cooling well. 85 out door 75 idwb super heat 35 sub cool 10. Txv metering device. 10 degree split temp. ????? Open the case and did see 2 out
  8. Replies
    1
    Views
    330

    Contractors lisence

    I've looked all over the place and I can not find a place or any information on how and/or where to take the the class/test to get my contractors lisence. I live in ocala Fl. Any info would be...
  9. Replies
    16
    Views
    1,122

    It sits in a square with four total condensers....

    It sits in a square with four total condensers. Condenser coil is clean. About 1.5 feet apart. It's a really bad set up. The units are about 6 years old. Coil is clean cause I cleaned them.
  10. Replies
    16
    Views
    1,122

    Comp is amping ok

    Comp is amping ok
  11. Replies
    16
    Views
    1,122

    52 is low side pipe temp. Yeah SC is high

    52 is low side pipe temp. Yeah SC is high
  12. Replies
    16
    Views
    1,122

    7.5 ton American standard

    Working on this unit customer says its not cooling like it should. I got 76 low side pressure 285 high side. Low side temp 52 high side 100. Got 100 degree entering dry bulb at condenser. I got a 14...
  13. Replies
    20
    Views
    1,325

    So is it normal for it to ice on the compressor...

    So is it normal for it to ice on the compressor side and ice half the head of the compressor?
  14. Replies
    20
    Views
    1,325

    I've never seen a CPR on a true case nor anywhere...

    I've never seen a CPR on a true case nor anywhere else. I've only been doing these small cases for little over a year. Been residential AC for over 15 years. I'm with a different company and they do...
  15. Replies
    20
    Views
    1,325

    First time on this brand. If it were a TRUE case...

    First time on this brand. If it were a TRUE case it would be fixed. I'm very familiar with them.
  16. Replies
    20
    Views
    1,325

    Just couldn't get suction line temp down past...

    Just couldn't get suction line temp down past about 45 to 50 degrees. I even opened the TXV but couldn't get pressure above 28
  17. Replies
    20
    Views
    1,325

    About 45 min fans never came on either in box

    About 45 min fans never came on either in box
  18. Replies
    20
    Views
    1,325

    It's a Howard/ McCray box

    It's a Howard/ McCray box
  19. Replies
    20
    Views
    1,325

    Box temp 65 no product in box, txv, 25 low side...

    Box temp 65 no product in box, txv, 25 low side 255 high side. SH was around 35. Didn't check SC but sight glass is full. It's 404a freon. That's about all I have. end of the day job you know
  20. Replies
    20
    Views
    1,325

    Three door reach in freezer

    Got this freezer in working on. I can't get the temp down. I noticed the crankcase pressure regulator was iceing on the comp side. This is a new freezer about a year old. I have never seen this on a...
  21. Replies
    33
    Views
    5,292

    Way to take this thread to the extreme guys lol....

    Way to take this thread to the extreme guys lol. Great post though I appreciate every reply
  22. Replies
    33
    Views
    5,292

    Thanks everyone. I swapped two terminals and it...

    Thanks everyone. I swapped two terminals and it was fine. It's been a long day no doubt summer has hit in FL. But is that the only way to tell if its wires correctly. There has to be a way to know...
  23. Replies
    33
    Views
    5,292

    3 phase ac compressor

    Just put a new comp in this unit roof top package. Wires everything up push contractor in and the comp comes on but not pumping. How do I know I have the wireing on the correct terminal? It's late...
  24. Replies
    7
    Views
    523

    Thanks mike ill look into that. Do you have to...

    Thanks mike ill look into that. Do you have to recover all the R12 or can you go in over top of it? Not that its that important . Cause this unit only holds 17 ounces.
  25. Replies
    7
    Views
    523

    Raetone reach in 47 cu ft freezer.

    Got this freezer the other day for a very fair price. Unfortunately it's R12. It had a leak it the cap tube. Easy fix. My question is.. Is there a drop in replacement for R12? I don't want to go...