  1. Replies
    13
    Views
    2,676

    you can search here for more info >>> ...

    you can search here for more info >>>

    http://www.hotfreshcool.com/visionpro_IAQ_features.html
  2. Replies
    28
    Views
    3,369

    The tax credit is a joke.. part of the stimulus...

    The tax credit is a joke.. part of the stimulus package, that has stimulated many to think they will save lots of money if they replace their ac/heat system... a $1500 tax credit will not amount to a...
  3. Replies
    13
    Views
    2,676

    you can go here to research your quoted equipment...

    you can go here to research your quoted equipment to see if it will qualify for the credit..

    http://www.energystar.gov/index.cfm?c=products.pr_tax_credits#c3

    your unit should meet or exceed...
  4. I said "get someone else" because he already has...

    I said "get someone else" because he already has doubt about this guy otherwise he would not have come here. He would be in his house doing something besides worrying if his heatpump is installed...
  5. heaterman: why would you start from scratch? You...

    heaterman: why would you start from scratch? You just need to figure out how many feet of liquid line you have in the system and subtract 15 ft from it for your factory charge and add about 0.6...
  6. He is not too consciencious if he left them with...

    He is not too consciencious if he left them with no heat pump and heat strips to take care of the rest of the season. they will be wasting alot of money without the heat pump operational.
    Get...
  7. Replies
    2
    Views
    490

    I own a Tempstar unit...they are great units... I...

    I own a Tempstar unit...they are great units... I have a heat pump and air handler... I dont own a furnace...So far I have had good luck with mine.
    Let us know how you make out with it.
    G/L
  8. Replies
    13
    Views
    1,144

    sometimes tstats are programmed with an...

    sometimes tstats are programmed with an undetermined or non settable feature. this feature will not allow the heat pump to come back on until the temperature reaches above the determined setpoint you...
  9. Replies
    28
    Views
    6,783

    I think The Tempstar looks the best out of all of...

    I think The Tempstar looks the best out of all of them. IMO
  10. Replies
    28
    Views
    6,783

    The specs are the same...I think the cabinets...

    The specs are the same...I think the cabinets they use are different... if you go to the websites each comparible model holds identical specs...
    ie... gotempstar.com, goheil.com, gocomfortmaker.com...
  11. Replies
    28
    Views
    6,783

    I own a Tempstar 17 Seer 2 Stage T4H736 (3 ton)...

    I own a Tempstar 17 Seer 2 Stage T4H736 (3 ton) Heat Pump coupled up to a Tempstar FVM4X36 Variable speed AH... R-410a system and it has been a great machine so far. It really throws out alot of...
  12. Replies
    24
    Views
    1,717

    Add a dirty coil or if it's a residence of a...

    Add a dirty coil or if it's a residence of a heavy smoker that will definately screw with the heat transfer. Location of the supply too...near the laundry area, how about the kitchen ....nice...
  13. Replies
    15
    Views
    2,329

    Thats why I stated in my previous post that you...

    Thats why I stated in my previous post that you will have to pay close attention, because it will not make any different sound....the airflow will increase by 20% and the temp will rise a little bit...
  14. Replies
    15
    Views
    2,329

    Hey, you will not find the hi and lo numbers on...

    Hey, you will not find the hi and lo numbers on the ARI site. The ARI site will give you the certified performance rating for your combination of the indoor unit matched up with your outdoor unit. It...
  15. Replies
    9
    Views
    8,770

    Since you will be installing the AH on the 3rd...

    Since you will be installing the AH on the 3rd floor if the vertical seperation exceeds 20ft you will have to follow the manufacturers recommendations for Long Line Sets... some equipment...
  16. Replies
    15
    Views
    2,329

    I will assume you have an outdoor unit model...

    I will assume you have an outdoor unit model C4H736

    Your COP @17degrees on low stage is 2.34
    Your COP @17degrees on high stage is 2.80
    HSPF rating of 8.9... your combination gives you 16.5...
  17. Replies
    15
    Views
    2,329

    yeah, once he posts his indoor and outdoor model...

    yeah, once he posts his indoor and outdoor model numbers I can look them up to check the combination rating..
  18. Replies
    15
    Views
    2,329

    you wont really be able to tell if your heat pump...

    you wont really be able to tell if your heat pump goes into 2nd stage unless you monitor it very closely. your compressor is single speed therefore you will not hear any difference on the outdoor...
  19. Replies
    22
    Views
    1,150

    Sounds like you will have to "weed" through your...

    Sounds like you will have to "weed" through your local HVAC contractors to find the right one who knows heat pumps... what you described in your first post sounds similar to mine...check pics out......
  20. Replies
    4
    Views
    479

    I know this may sound silly but,... since R-410a...

    I know this may sound silly but,... since R-410a is less prone to fractionation because it is a near azeotrope refrigerant. Can the refrigerant be reused from the recovery tank? or will fresh...
  21. Replies
    4
    Views
    479

    RE: Quick Technical Question

    Ok ... I got home and reviewed my paperwork... all of you guys were right.

    My Low side psi was 25 not 225 and my high side was 30 psi.... I believe I found my leak though ...take a look at the...
  22. Replies
    9
    Views
    593

    yeah lets hope so ...this last guy scared me!

    yeah lets hope so ...this last guy scared me!
  23. Replies
    9
    Views
    593

    Oh no...not blinded again... lol what is wrong...

    Oh no...not blinded again... lol

    what is wrong with my statment?
    if I have hi suction and lo discharge what could it mean? thats all....
    tech is coming out tomorrow and just wanted a heads...
  24. Replies
    9
    Views
    593

    Quick Technical Question...

    I have an R-410a heat pump running hi suction pressure (225psi) and low discharge pressure (45psi)...what could be the problem with this system? I have a tech coming tomorrow and dont want to get...
  25. Replies
    6
    Views
    616

    quick tech question