  1. Replies
    19
    Views
    888

    I use my lips and syphon it out, figure my lips...

    I use my lips and syphon it out, figure my lips have touched worse :whistle: lol. The pump looks good though, got one for the boat!
  2. Replies
    16
    Views
    797

    Is it not kind of useless with 410 to have a...

    Is it not kind of useless with 410 to have a sight glass? I honestly have never put one on in years but it was my understanding that 410 will flash off in the liquid line even at perfect charge. Is...
  3. Replies
    4
    Views
    567

    Mike Holmes is a douchebag? How so? He actually...

    Mike Holmes is a douchebag? How so? He actually is the only one out there in fantasy land that tells it the way it is. Quality jobs require quality money. kind of arrogant but not douchebag lol.
  4. Replies
    16
    Views
    797

    How many cfm's? Temp drop over coil? Wetbulb temp...

    How many cfm's? Temp drop over coil? Wetbulb temp indoors?
  5. Replies
    4
    Views
    177

    if natural gas is not available what choice do...

    if natural gas is not available what choice do you have? throw a heat pump on to lower the cost. Propane is cheap here at the moment but you just never know lol.
  6. Replies
    16
    Views
    396

    Not familiar with the Carrier but it should...

    Not familiar with the Carrier but it should dehumidify better than the original equipment given its a variable speed unit. I would assume that is set up wrong. have installer come back and explain...
  7. Replies
    11
    Views
    346

    In Ontario its done by a certified licenced duct...

    In Ontario its done by a certified licenced duct designer that also does a heat gain/loss. If anything AC's tend to be a tad undersized when a heat gain is done. Honestly O have never had a customer...
  8. Replies
    11
    Views
    346

    Actually this question was put to me by a home...

    Actually this question was put to me by a home owner as to why he should purchase a two stage as opposed to a single stage and might this be a problem. After thinking about it I couldnt answer him. A...
  9. Replies
    11
    Views
    346

    Actually I just cut the mountain pic off the beer...

    Actually I just cut the mountain pic off the beer can and tape it too the suction line. When it turns blue I know Its charged perfectly lol.
  10. Replies
    11
    Views
    346

    So if there has been a proper duct design done...

    So if there has been a proper duct design done (always done on new construction here) then you are saying it should be fine even at half throttle? Just not getting the concept is all lol. I guess Im...
  11. Replies
    11
    Views
    346

    Are not all ducts designed for max airflow and...

    Are not all ducts designed for max airflow and thats my concern. On low stage will there be enough air to reach the farthest runs re two story etc.
  12. Replies
    11
    Views
    346

    Duct issues with two stage

    Just wanted some input on changing out a single to a two stage furnace and AC unit. On first stage would you not run into air flow issues at the farthest ducts, expecially on multi story houses? Are...
  13. not sure how they do the piping but you can never...

    not sure how they do the piping but you can never go wrong with a biflo drier if you find a place to put it IMO. The expansion valve is on the outdoor unit in most cases.
  14. Replies
    4
    Views
    493

    You'll probably need two anyways, depending on...

    You'll probably need two anyways, depending on house and climate
  15. Replies
    12
    Views
    999

    Should have wired W\defrost from cond to w1 on AH...

    Should have wired W\defrost from cond to w1 on AH then wired w from stat to W2 allowing for minimal heat on defrost and full heat on call.
  16. Climate01 is right just do the whole house at the...

    Climate01 is right just do the whole house at the panel if other things are being effected. Really not that pricey. Many insurance companies are insisting they are installed to cover electronics...
  17. Would a bad contactor effect the line side? It...

    Would a bad contactor effect the line side? It should have taken out the load side.
  18. Replies
    17
    Views
    1,418

    Seen a few with rebar or drain type grills but...

    Seen a few with rebar or drain type grills but geez lets just for a sec look at a few of the code violations here. Thats why this thing is there still. Codes were ignored by customer or previous...
  19. Replies
    17
    Views
    1,418

    Not sure about USA but in Ontario by code it...

    Not sure about USA but in Ontario by code it would be shut off due to disconnect location, need to permanently remove the boards in front! That is only one of many reasons to run away lol.
  20. Replies
    18
    Views
    2,122

    Whats wrong with a pulse? There a fine unit, just...

    Whats wrong with a pulse? There a fine unit, just do a pressure test. Ok let the slamming beginning lol.
  21. Replies
    8
    Views
    587

    Should have check valve yes but you could just...

    Should have check valve yes but you could just shut off valve for summer
  22. Replies
    22
    Views
    1,848

    Well you can get SH at condenser, that would...

    Well you can get SH at condenser, that would narrow it down a bit. Yes you should have ran, now you own it!!! how are filters being replaced? can you get a camera in there, not that will help. If you...
  23. Thread: work fatigue

    by waterdawg
    Replies
    19
    Views
    1,654

    😳 well Cap you may want to start thinking exit...

    😳 well Cap you may want to start thinking exit plan lol. Try 53!!! Actually I have been lucky enough to be able to spend time in field as well as behind a desk. The desk thing is nice when the ladder...
  24. Replies
    26
    Views
    1,600

    We go through soffit all the time on existing...

    We go through soffit all the time on existing houses. Slimduct all outside lines. Guys do a great job. We just did an century old heritage home with 4 units and 12 heads that made it into a bunch of...
  25. Thread: work fatigue

    by waterdawg
    Replies
    19
    Views
    1,654

    I hear ya Cap! I'm falling apart like a WalMart...

    I hear ya Cap! I'm falling apart like a WalMart shirt!!! Every year gets a bit harder, hotter, and longer!!
  26. Thread: TXV Issues!!

    by waterdawg
    Replies
    12
    Views
    2,294

    Sorry about typing! Small phone, big fingers lol!

    Sorry about typing! Small phone, big fingers lol!
  27. Thread: TXV Issues!!

    by waterdawg
    Replies
    12
    Views
    2,294

    Ok so update to the txv issue!! Had to more that...

    Ok so update to the txv issue!! Had to more that were overcharged yesterday. The units are again ADP but I think emerson valves this time lol. How long do you have to wait for these micro channel...
  28. Replies
    15
    Views
    1,321

    In saying that if its exposed we change...

    In saying that if its exposed we change it.....always!
  29. Replies
    15
    Views
    1,321

    Opps sorry yup smaller lol. So just the last part...

    Opps sorry yup smaller lol. So just the last part of the question? Most of our units are 3/4 and most existing are the same. I did call about a 30' that was 5/8 and unit was 3/4, they said it would...
  30. Replies
    15
    Views
    1,321

    Are you finding that the lines are smaller than...

    Are you finding that the lines are smaller than is required. Have you consulted with manufacturer as to wether or not the smaller size is ok?
  31. Thread: TXV Issues!!

    by waterdawg
    Replies
    12
    Views
    2,294

    We have had that as well but this is an actual...

    We have had that as well but this is an actual txv issue. Not to say its not our fault though re: purging, etc. just trying to establish if we are the only ones. That would narrow it down to us lol.
  32. Thread: TXV Issues!!

    by waterdawg
    Replies
    12
    Views
    2,294

    TXV Issues!!

    Having huge problems this year with ADP coils with parker valves. I've had 6-7 fail after a week and 1-2 fail on startup. They will either stick closed intermittently or never open. I have tried to...
  33. Replies
    29
    Views
    2,279

    Actually it leads to costly follow ups for us...

    Actually it leads to costly follow ups for us lol. Every job we do is inspected by me and if not right Its fixed. Its been a great program in that quality has improved 10 fold. It cost lots to do but...
  34. Replies
    24
    Views
    1,253

    Ok last time, sorry OP! Why yes I have! :) Again...

    Ok last time, sorry OP! Why yes I have! :) Again never saw an R410 system get close with proper airflow. All I said was they are not required. If you are arguing that they are necessary then you are...
  35. Replies
    24
    Views
    1,253

    Also I will not debate this on someone else's...

    Also I will not debate this on someone else's thread any longer. If you still want to discuss it PM me. If you do find documents that actually say it is required post them and yes i will admit I am...
  36. Replies
    24
    Views
    1,253

    When the system is in defrost the pressures will...

    When the system is in defrost the pressures will never reach 600!! Its in cooling and the evaporator is cold, put your gauges on and you will see this! You are lucky to get 150 on suction and maybe...
  37. Replies
    24
    Views
    1,253

    So lets clarify lol. You cycle the burner when in...

    So lets clarify lol. You cycle the burner when in defrost? Defrost terminates and now you keep heat pump off till plenum temp drops? Not sure how you do this. Got a wiring diagram? And yes typically...
  38. Replies
    24
    Views
    1,253

    Yup pretty much what I said lol. Do you have...

    Yup pretty much what I said lol. Do you have documents that say sensor is reqhuired? I use to put them on but all manufactures I talked say no. Is it a good ideal, i guess but as stated there is a...
  39. Replies
    24
    Views
    1,253

    Ummm sorry but you are wrong. There is a terminal...

    Ummm sorry but you are wrong. There is a terminal on outdoor unit that is typically marked w/66 (york) this terminal sends 24 to w or w1 at furnace when heatpump is in defrost so yes I guess its not...
  40. Replies
    24
    Views
    1,253

    They work great but you still need to add a relay...

    They work great but you still need to add a relay and if mounting a fan center it is very easy to override limit through feed back on fan line. Again unless you know what your doing dont do it. I've...
  41. Replies
    24
    Views
    1,253

    Well actually they can and do run at the same...

    Well actually they can and do run at the same time! When there is a defrost call the oil will be allowed to operate. But to OP you need someone that knows what their doing!
  42. Thread: Bryant txv

    by waterdawg
    Replies
    205
    Views
    24,856

    Sorry meant to quote superpro ^^^^

    Sorry meant to quote superpro ^^^^
  43. Thread: Bryant txv

    by waterdawg
    Replies
    205
    Views
    24,856

    Wow!!! Heat getting to you man!!! Oh and we don't...

    Wow!!! Heat getting to you man!!! Oh and we don't say retarded anymore we say special lol. Perhaps you need to read the post a bit more closely. I thought that was kind of humorous actually.
  44. Replies
    29
    Views
    2,279

    Also with the scroll being used more and more its...

    Also with the scroll being used more and more its really not a great ideal to pump them down. If it happens to go into a vacume you could destroy the compressor. With these newer systems it takes a...
  45. Replies
    29
    Views
    2,279

    Actually they do not hold the system charge and...

    Actually they do not hold the system charge and also depending on the matched coil you may be adding significant amounts of gas. If the tx is restricted the condensor loads up with liquid and will...
  46. Replies
    29
    Views
    2,279

    With the new micro channel condensors head will...

    With the new micro channel condensors head will go up due to no room to hold charge would it not?
  47. Replies
    29
    Views
    2,279

    Would the head not be higher than normal?

    Would the head not be higher than normal?
  48. Thread: No Superheat

    by waterdawg
    Replies
    57
    Views
    5,473

    Yes SC would be nice. As well as indoor WB. Lots...

    Yes SC would be nice. As well as indoor WB. Lots of new techs are lacking in the basics and fail to look at the whole picture. A great tool when starting out is a troubleshooting schematic from one...
  49. Thread: No Superheat

    by waterdawg
    Replies
    57
    Views
    5,473

    Honestly if I was there And airflow checked out....

    Honestly if I was there And airflow checked out. I would be pulling gas to get it to around 15 SH not knowing wetbulb! Did anyone record readings from last visits? Perhaps its ran this way for a bit.
  50. Thread: No Superheat

    by waterdawg
    Replies
    57
    Views
    5,473

    So ^^^^ charge is low? Yes you could weigh in...

    So ^^^^ charge is low? Yes you could weigh in charge but its probably going to be hard to get exact factory specs. Yes you could get all the specs, measure lineset, and add filter. But really its...
Results 1 to 50 of 194
Page 1 of 4 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Quality Home Comfort Awards