    Charge removed and put back as per label ......

    Charge removed and put back as per label ... water cooled.. 85 in 97 out.. filters clean... super heat 12 degrees .. also strainer clean. this is a heat pump unit.orifice metering device......
  3. Replies
    5
    Views
    394

    crazy pressures

    Guys checked charge which is correct.This is a 22 system 25 oz compressor at rated amps of 7 but compressor very ot suction is low 40lb head 200. I know there isnt enough to cool compressor. do you...
  4. Replies
    59
    Views
    6,139

    fielpiece vs fluke

    Been using Fluke for 15 years. Last year got a fieldpiece s730 Its great,You can actually Plug in different heads to change the tool into different ones.Like i said my field piece is over a year old...
  5. Replies
    4
    Views
    894

    yah thanks for the info

    yah thanks for the info
  6. Replies
    1
    Views
    328

    problem with return air

    I have a bryant 3ton split unit. the house is approx 3000sq ft.Was originally there when i bought house. Have T stat on first floor along with 1 large return air grill. 2nd floor has Large return in...
  7. Replies
    3
    Views
    810

    Ya thats what im thinking thanks.

    Ya thats what im thinking thanks.
  8. Replies
    3
    Views
    810

    low motor amperage

    On my main air handler, will the fan motor draw less amps if the return damper shuts. Or will the amperage go up due to the motor working harder trying to pull back air causing amps to go up.
  9. Replies
    4
    Views
    894

    decreased fan motor amperage

    :worthless:On my air handler, will i get lower than normal amperage readings, if my return air damper shuts or will the motor struggle trying to pull air back causing higher amperage.
  10. Thread: Subcooling

    by icedr024
    Replies
    3
    Views
    579

    Thanks for the advice.

    Thanks for the advice.
  11. Thread: Subcooling

    by icedr024
    Replies
    3
    Views
    579

    Subcooling

    I was always taught that you should never mess with design of original equiptment. I have a Commericial Building with 40 Blazer package units about 90 tons each. We have had many problems with the...
  12. Replies
    0
    Views
    421

    subcooling Problem

    Way back in school we learned never to mess with the design of a peice of equiptment.Im in a building with 300 old Blazer 90 ton package units. Recently we started a capital improvement project where...
  13. Replies
    6
    Views
    961

    Yes, we use in our shop the dremel(cordless) and...

    Yes, we use in our shop the dremel(cordless) and we have a dewalt small grinder that works well. The dremel works a little better and doesn not leave any little peices of copper. which you Dont want...
  14. Replies
    21
    Views
    2,698

    Roto locks

    I have old Blazer 90 ton package units in my building. We have about 300 15 ton Bristol compressors with Roto locks. Although My roto locks are larger
    1 1/8 I have the same problem. I spray them...
  15. Although I did not have the pleasure of meeting...

    Although I did not have the pleasure of meeting Bruce, He sounds like a very nice person,and Im sorry I will not have the oppurtunity to meet him.I do feel that he was very much loved by his peers,...
Results 1 to 15 of 15
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event