  1. try this one

    try this one
  2. Replies
    11
    Views
    1,004

    I would definitely go straight LON to the devices...

    I would definitely go straight LON to the devices if you are needing more than just a few crucial points in the Ax. We had a site that the BCU would crash every day due to the % processor idle time...
  3. Replies
    1
    Views
    547

    I don't think it can do both simultaneously. You...

    I don't think it can do both simultaneously. You have to choose the communication interface in the TU setup of the chiller, so I think the LON card can be installed and you can still communicate...
  4. If you have Tracer Summit on your laptop you can...

    If you have Tracer Summit on your laptop you can remotely access the Tracer Summit. Assuming it is not a BMTS BCU and it has ethernet connectivity.
  5. The button is probably the one that says "Trane...

    The button is probably the one that says "Trane Network use only" That is for Trane Techs to renew their license to upgrade the techview to Kestrelview. Kestrelview has a few added features for Trane...
  6. The UPCM is a Comm4 device. If you have rover,...

    The UPCM is a Comm4 device. If you have rover, you can try and search the link with it and see what you can see. I don't think you can see the UPCM with Rover, but you should be able to see the UV...
  7. Replies
    3
    Views
    392

    You've got mail.

    You've got mail.
  8. Here is what I could come up with a quick search

    Here is what I could come up with a quick search
  9. Replies
    4
    Views
    605

    All the Trane binarys are a 2 part SNVT. they...

    All the Trane binarys are a 2 part SNVT. they require a true/false and also a %. You could write the % to 100 all the time and switch the binary on/off and it would accomplish the task.
  10. Replies
    22
    Views
    3,299

    My email address is in my profile :)

    My email address is in my profile :)
  11. Replies
    22
    Views
    3,299

    Sent to you too :)

    Sent to you too :)
  12. Replies
    22
    Views
    3,299

    coming to you!

    coming to you!
  13. Replies
    22
    Views
    3,299

    Send me your email. I can get you the Range and...

    Send me your email. I can get you the Range and offset calculator and any IOMs you need
  14. You are correct. I wasn't thinking about the...

    You are correct. I wasn't thinking about the difference in static tubes and pitot tubes. I have both and use the static tip if I only need static pressure.
  15. I would use the pitot tubes to take the...

    I would use the pitot tubes to take the measurements with. If you insert a tube into the duct, you can get different readings when the tube is in different positions due to the velocity pressure of...
  16. Replies
    0
    Views
    463

    Trane VV551 integration with JACE

    I have a job that has 18 generic VAV boxes with the Trane VV551 VAV retrofit controllers. We used a 3rd party to integrate them into the JACE that is installed on the campus of my customer. The...
  17. Replies
    13
    Views
    1,405

    I was just talking to one of my co workers this...

    I was just talking to one of my co workers this morning about that. He said the valves have been redesigned and the replacement won't work with the old chiller module that controls the...
  18. Replies
    2
    Views
    1,475

    Try BAS-SVX17B-EN. I can e-mail it to you if you...

    Try BAS-SVX17B-EN.
    I can e-mail it to you if you can't find it. That may be the one you are looking for.
  19. Replies
    7
    Views
    982

    If the sensors are out of calibration, just...

    If the sensors are out of calibration, just replace them. They cost about $10 each. that is way less than the cost of the Rover service tool.
  20. Replies
    3
    Views
    508

    What is wrong with it?

    What is wrong with it?
  21. Replies
    2
    Views
    915

    There are configurations and programs that will...

    There are configurations and programs that will have to be downloaded into the new PCM. You will also need the program to set it up. If you happen to have copies of the old programs, you are good. If...
  22. Replies
    3
    Views
    837

    Go into the setup menu and enable tracer control....

    Go into the setup menu and enable tracer control. then you should be able to select tracer as a setpoint source.
  23. Replies
    18
    Views
    1,076

    I did some searching, and cannot find where It...

    I did some searching, and cannot find where It was mentioned. I'm sorry I thought I had posted a reply.
    If time permits, I'll make a couple calls today and inquire about it to some of the guys that...
  24. Replies
    18
    Views
    1,076

    I think it can be done, but that is a lot of...

    I think it can be done, but that is a lot of work. I will check around today and see if I can find some service bulletin or something like that that mentions the 580 being seen as a GLD.
  25. Replies
    18
    Views
    1,076

    I can't see any newer revisions of V15 SP1 on the...

    I can't see any newer revisions of V15 SP1 on the website. It seems like one version of summit brought in the MP580/581s in as a GLD.
    Have you tried reverting the firmware in the 580 to an earlier...
Results 1 to 25 of 105
Page 1 of 5 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event