  1. This sounds more and more like a diy.

    This sounds more and more like a diy.
  2. Someone once said at 200 micron or below, oil...

    Someone once said at 200 micron or below, oil will boil off. I totally could not and will not agree.
  3. If we can't replace the lines, we do not flush...

    If we can't replace the lines, we do not flush unless it's a burn-out. Always empty an 80-CF N2 cylinder at 600-PSI you are good to go. the oldest system done that way is now
    7 years old, no problem.
  4. Replies
    7
    Views
    1,540

    You have the post count, go ahead apply for a pro...

    You have the post count, go ahead apply for a pro membership.
    You will get a lot more detailed info there.
  5. Replies
    23
    Views
    2,117

    we don't really know his heat gain, insulation...

    we don't really know his heat gain, insulation and sunlight hours.
  6. Replies
    23
    Views
    2,117

    you probably are dealing with several different...

    you probably are dealing with several different issues here (like others suggested)"
    1. water in the pan (leveling? correct drain hole? correct P trap? overflow shutoff?)
    2. wrong system charge...
  7. I don't believe it's a fan motor. If internal...

    I don't believe it's a fan motor. If internal thermal protection, how do you explain the 30-min thing and cycling the power solve the problem for another 30 min?
  8. BTW, goodman never had a model GSH140181, could...

    BTW, goodman never had a model GSH140181, could be GSH130181?
  9. Too much ifo I probably already attracted the...

    Too much ifo

    I probably already attracted the forum cop, you need to call the original installer, the system should still be in his labor warranty.
  10. Replies
    249
    Views
    21,019

    To me, it seems that there hasn't been an air...

    To me, it seems that there hasn't been an air filter installed or it hasn't been changed for a long time. The tech said the unit is "new"?
  11. Replies
    69
    Views
    13,401

    One thing I know is if my customer's condenser...

    One thing I know is if my customer's condenser needs a replacement, he won't be very happy to be forced to upgrade the whole system to R410a. Meanwhile, I have stocked up on jugs of R22.
  12. Replies
    12
    Views
    3,010

    another thought, don't just upgrade the furnace...

    another thought, don't just upgrade the furnace without investigating your duct system, most likely it won't support the full 1600cfm anyhow.
  13. Replies
    12
    Views
    3,010

    I don't know of a 4-ton coil that can be made...

    I don't know of a 4-ton coil that can be made into an "A" cabinet -
    14.5" wide. Is your current coil over hanging the furnace?

    a 1200 cfm blower may work with a 4-ton AC, it will just be a lot...
  14. Replies
    12
    Views
    1,348

    without looking into details (tonnage, IDDB/IDWB,...

    without looking into details (tonnage, IDDB/IDWB, air flow...), 250/90 sounds already too low (ODT 98F), but he "bled" it down? Did he vent R22 into the air? Is yes, report him and claim your $25000...
  15. Replies
    10
    Views
    954

    We had a TWE031 last week as well. My question is...

    We had a TWE031 last week as well. My question is even tho the "touch-screen" tstat was wired wrong, it doesn't seem that he damaged the air handler at all. the HVAC guy should only have needed to...
  16. Replies
    7
    Views
    407

    If a contractor installed it for you, you should...

    If a contractor installed it for you, you should get his a$$ back to check it out. If you did it yourself, I am afraid you won't get pro answers here.
  17. Replies
    16
    Views
    2,097

    I would check for refrigerant restrictions across...

    I would check for refrigerant restrictions across metering device and f/d.
  18. Replies
    17
    Views
    885

    you mean hall of xame?

    you mean hall of xame?
  19. Replies
    17
    Views
    885

    OK, you will have a dead piece of equipment when...

    OK, you will have a dead piece of equipment when winter comes.

    The first time you turn on the gas heating, your secondary HX will be
    quickly filled with water and your pressure switch will kill...
  20. Replies
    17
    Views
    885

    No you have a five position unit!

    No you have a five position unit!
  21. Replies
    17
    Views
    885

    so is it a gas FURNACE or AHU? model # will help.

    so is it a gas FURNACE or AHU?
    model # will help.
  22. Replies
    17
    Views
    885

    the inside clearance between HX and cabinet is...

    the inside clearance between HX and cabinet is the smallest on the back. Also:
    if it's a 80eff, seriously dangerous venting issues in belly-up position, in fact, only
    a handful power-vented 80eff...
  23. Replies
    17
    Views
    885

    gas furnace can only be installed in horizontal...

    gas furnace can only be installed in horizontal positions with either of its SIDES on the bottom, if that unit is allowed horizontal installation at all.
  24. Replies
    20
    Views
    2,119

    no wonder...

    no wonder...
  25. Replies
    20
    Views
    2,119

    how do you know it was DIY? some so-called...

    how do you know it was DIY? some so-called contractors are no better than DIYers.