  1. Replies
    6
    Views
    437

    Have them purchase the bacnet server through the...

    Have them purchase the bacnet server through the service agreement, price is significantly less, they will probably attempt to upgrade the machine as well as insight revision, which may or not be...
  2. Replies
    6
    Views
    437

    Unless the customer still has a service agreement...

    Unless the customer still has a service agreement with Siemens, they will probably gauge you on the price, and probably try to sell you a new server as well. They will need to add the server license...
  3. Yes it communicates through the mmi port, it is...

    Yes it communicates through the mmi port, it is very slow.


    Sent from my iPhone using Tapatalk
  4. Dadof5 My email is in my profile, email me with...

    Dadof5
    My email is in my profile, email me with questions.



    Sent from my iPhone using Tapatalk
  5. I've done it, not conventionally though as to all...

    I've done it, not conventionally though as to all jace driver options would not work. We had the customer purchase insight BACnet server and we made the insight server a glorified bacnet router.

    ...
  6. Replies
    3
    Views
    233

    No WCIS is for accessing TECs and other P1...

    No WCIS is for accessing TECs and other P1 devices.


    Sent from my iPhone using Tapatalk
  7. Replies
    4
    Views
    337

    Your best bet might be to call around and see if...

    Your best bet might be to call around and see if any other vendors may be able to help you manage the system. Unfortunately you are locked in to Siemens for true product support, but there are plenty...
  8. Nick is correct, remote notification is licensed,...

    Nick is correct, remote notification is licensed, and can only be purchased through your local Siemens branch.


    Sent from my iPhone using Tapatalk
  9. Replies
    14
    Views
    1,123

    Tridiumtech, I am currently working with Tridium...

    Tridiumtech,
    I am currently working with Tridium everyday. Thank you


    Sent from my iPhone using Tapatalk
  10. Replies
    14
    Views
    1,123

    I worked for Siemens for 10 years and left a year...

    I worked for Siemens for 10 years and left a year ago. With Siemens you will work 95% of the time on the apogee line. The only experience you will get with other venders will be through integration...
  11. Replies
    5
    Views
    324

    Do you have an insight front end. You can also...

    Do you have an insight front end. You can also view PPCL and point database from the system profile.
    These devices are dinosaur and Siemens decided years ago to make them difficult to use by...
  12. The Siemens to Lon integration is bulky and at...

    The Siemens to Lon integration is bulky and at this point obsolete. They are pushing you to go BACnet because of this. Siemens will price this job so BACnet makes more sense. $$


    Sent from my...
  13. Replies
    4
    Views
    265

    I believe the 550-530 tec is a Lon heat pump...

    I believe the 550-530 tec is a Lon heat pump controller.


    Sent from my iPhone using Tapatalk
  14. It is easier for Siemens to push you to go...

    It is easier for Siemens to push you to go BACnet. There are several different ways for them to achieve this. All of them costly. What are your concerns?


    Sent from my iPhone using Tapatalk
  15. Replies
    12
    Views
    787

    There a many different sequences to control your...

    There a many different sequences to control your dampers. Simple control would be to control your economizer to maintain discharge are set point. You also have air quality control where you monitor...
  16. Replies
    7
    Views
    448

    These are Siemens apogee devices. You can do...

    These are Siemens apogee devices. You can do everything you need with the PXC controller. Unfortunately programming this will not be easy, for someone not familiar with PPCL, especially thru hyper...
  17. Replies
    6
    Views
    437

    I the research I have done is that the driver is...

    I the research I have done is that the driver is p1 devices only. I needed to install Siemens bacnet server and use the insight machine as a "gateway" in order to make this work.


    Sent from my...
  18. Replies
    17
    Views
    1,279

    Yes it has several different applications per...

    Yes it has several different applications per stat with different amount of relays per part number. The Kmc website also has an interactive demo


    Sent from my iPhone using Tapatalk
  19. If the only thing that has changed was moving the...

    If the only thing that has changed was moving the server to the new location, then this is where you have to start. Have you replaced the switch?
  20. Replies
    2
    Views
    263

    The pxcm is unable to connect, has anything...

    The pxcm is unable to connect, has anything changed on the network? Try a warm start (battery stays in)
  21. Replies
    3
    Views
    244

    You press it once in the middle to put it into...

    You press it once in the middle to put it into "hand" and a second time on either side to open or close the relay.


    Sent from my iPhone using Tapatalk
  22. Replies
    4
    Views
    335

    You will not be able to pull any point expansion...

    You will not be able to pull any point expansion into tridium. The point database resides in the field panel which is P2 communication. As of right now there is no driver for p2 only p1 which the tec...
  23. Replies
    6
    Views
    648

    Siemens Bacnet BBMD Help please?

    You need to have a BBMD configured on both subnets to route the BACnet packets across the router. You will need to have two in order to communicate. The chiller may have a BACnet table configuration....
  24. Replies
    16
    Views
    1,142

    Thanks Sam, My needs are a portable scope that...

    Thanks Sam,
    My needs are a portable scope that can be used to verify readings on customers RS485 trunks prior to integration. I'd like to be able to do screen captures on my laptop. I'm pretty...
  25. Replies
    16
    Views
    1,142

    Oscilloscope recomendations

    I have been given the green light to purchase a oscilloscope for our department. I would like to get recommendations.
    Thank you in advance.
  26. Best practice is to run your VFD with at least...

    Best practice is to run your VFD with at least three hard wired point, start/stop, status and your speed command. I don't like to pass the covs over the network.
  27. Replies
    1
    Views
    435

    N2 reference termination at Jace.

    what is the best practice for terminating the reference wire at the Jace. And also the proper grounding of the shield? is anyone using a 100 ohm PTC thermistor to terminate the shield?
  28. Your right dingman, thanks for clarifying.

    Your right dingman, thanks for clarifying.
  29. We're doing this integration. P1 to Jace. It...

    We're doing this integration. P1 to Jace. It helps that I am ex-Siemens. Each Fln truck can reside on a separate port. Any point expander ie DPU, mpu, bim and uc will not discover, and you will...
  30. The line in ppcl would be unresolved

    The line in ppcl would be unresolved
  31. Siemens: Unbundle FLN device points to field panel??

    Unless it's the day/night point it will need to be unbundled, in they system profile, I believe under tools.
  32. Replies
    8
    Views
    528

    Is the Emerson unit propriety communication? I...

    Is the Emerson unit propriety communication? I read nothing of open protocol in their spec.
  33. Replies
    1
    Views
    308

    Metasys UNT141 BI-4 Pulse configuration

    We are taking over a JCI system with UNT141 controllers and will be tying the N2 network to a JACE. I know that the UNT141 is capable of being configured as a pulse accumulator, but can not find...
  34. Replies
    3
    Views
    374

    It is a fume hood controller, I'll look around...

    It is a fume hood controller, I'll look around for the tech sheet.
  35. Replies
    37
    Views
    13,888

    Are there any PXC controllers that have manual...

    Are there any PXC controllers that have manual knobs like some MEC controllers? As in being able to manually modulate 0-10V output.

    Yes there is a part that takes the battery cover of the PXC and...
  36. I would have rather a customer change day night...

    I would have rather a customer change day night set points, CTL setpoint overrides these values and depending on the firmware in your tec, might not appropriately control heating amid cooling. He...
  37. If this were still a Siemens system they would...

    If this were still a Siemens system they would tell you to unbundle the points you would want to see on a graphic, in your case to be commanded form the jace. IYour network shouldn't have an issue as...
  38. You will need to unbundle these points thru hyper...

    You will need to unbundle these points thru hyper terminal.

    Sent from my DROID4 using Tapatalk
  39. What version of apogee and what type of...

    What version of apogee and what type of controller are we dealing with?

    Sent from my DROID4 using Tapatalk
  40. Are these points "unbundled" ? Sent from my...

    Are these points "unbundled" ?

    Sent from my DROID4 using Tapatalk
  41. Replies
    8
    Views
    750

    I'm doing a trane job now with about 300 trane...

    I'm doing a trane job now with about 300 trane uc400 and uc600s going thru a jace with no issues.
  42. Replies
    10
    Views
    865

    Keith, I haven't had an opportunity to throw it...

    Keith, I haven't had an opportunity to throw it in my station yet, but what you gave should do great. Thank you.
  43. Replies
    10
    Views
    865

    I'm actually reading a numeric point and using a...

    I'm actually reading a numeric point and using a multiplication block. The pulse accumulator discovered as a numeric point.
  44. Replies
    10
    Views
    865

    email added, thank you Keith.

    email added, thank you Keith.
  45. Replies
    10
    Views
    865

    Totalized gas usage in niagara

    I have a pulsed input that I am multiplying to get my adjusted gas usage. I want to get the usage broken down per month but can't seem to get it to reset on the first of the month. I am still very...
  46. Replies
    1
    Views
    414

    The trend collection time specified in scheduler...

    The trend collection time specified in scheduler determines how soon you will see data in your trend collection. If you need to see sooner info run a panel trend collection.

    Sent from my DROID4...
  47. Replies
    8
    Views
    624

    You know what I meant. Lol

    You know what I meant. Lol
  48. Replies
    8
    Views
    624

    I didn't even realize you said alc server, not...

    I didn't even realize you said alc server, not Shute whether you can do this, you may be able to talk to the controllers depending on you set up, but you can not have two masters.
  49. Replies
    8
    Views
    624

    What flavor BACnet, do you have the BACnet server...

    What flavor BACnet, do you have the BACnet server license?
  50. Replies
    9
    Views
    649

    That is exactly what I was looking for preciate...

    That is exactly what I was looking for preciate it!