  1. Replies
    47
    Views
    1,144

    Be interesting to power the furnace up on an...

    Be interesting to power the furnace up on an alternative circuit from the busses. Definitely going to be a loose connection some where.... Wish I was there I love calls like this.

    On one today ,...
  2. Replies
    47
    Views
    1,144

    When you unplugged the ignitor on a call for heat...

    When you unplugged the ignitor on a call for heat the board didn't provide 110-120 volts momentarily before giving you a flash error code?

    I dam sure wouldn't have left there without knowing...
  3. Replies
    47
    Views
    1,144

    How is it you couldn't just use your meter test...

    How is it you couldn't just use your meter test leads down into the top of the Molex connector or some test leads...

    Man you need to outfit yourself with some basic gear... Seriously going back......
  4. Replies
    47
    Views
    1,144

    Board and ignitor have been replaced. This...

    Board and ignitor have been replaced. This problem with the ignitor not teaching temp is the original complaint reoccurring with a new board and ignitor ?
    if that's the case be checking the ignitors...
  5. Replies
    47
    Views
    1,144

    I'd want to know what the voltage is at the...

    I'd want to know what the voltage is at the ignitor when it's failing?
  6. Replies
    7
    Views
    695

    Been using 3/4" wall UV Resistant but this...

    Been using 3/4" wall UV Resistant but this inspector want me to wrap it with foul tape.
  7. Replies
    7
    Views
    695

    Lineset UV Protection

    What are your inspectors requiring for UV protection on your Insul-tube ?
  8. Thread: TXV Question

    by AllTemp
    Replies
    11
    Views
    991

    Starters verify txv Operation. Disconnect the...

    Starters verify txv Operation. Disconnect the bulb warm it up watch your pressures. If your suction climbs I would look for debri in the inlet screen.
  9. My opinion would be contactor after your...

    My opinion would be contactor after your statement pushing in the plunger. Cost of contactor change it!
  10. Replies
    62
    Views
    3,961

    I remember getting booted of alt.hvac news feed...

    I remember getting booted of alt.hvac news feed promoting the site,lol!
  11. Replies
    62
    Views
    3,961

    One foot in the grave , their definately throwing...

    One foot in the grave , their definately throwing dirt on sometimes... A little crusty but still here
  12. Replies
    39
    Views
    2,039

    Mini Split Set Point Issues

    Hey Ya'all!!!! Homeowner of this thread has contacted me for some assistance.

    Its my understanding there may be a resistor on the board that maybe giving a wide dead band ???

    I understand this...
  13. Replies
    37
    Views
    2,784

    My thought on this mess as i understand it is...

    My thought on this mess as i understand it is there doesn't seem to be any regulation on the bypass dampers. Do you know if their Barometrically adjusted or Electronically dampers. I prefer...
  14. Replies
    0
    Views
    828

    Coleman Polar Prince

    Anyone familiar with certainty what this old dinosaur would be?

    Coleman Polar Prince

    Model #6942A801

    S/N #3691678

    Called Coleman forwarded to their Mobil Home division they can't find any...
  15. Replies
    31
    Views
    1,724

    Overboard?

    This is hardly overboard... The thread started from some twit that didn't have a clue about anything saying he was sick and tired...

    Get a grip in my wifes district alone the poltics between the...
  16. Replies
    31
    Views
    1,724

    Recap

    Sounds like things are a little different in NJ... here we share cost of medical...for the last 3 years my wife along with hundreds of other teachers hot fired because the budget... my wife was...
  17. Replies
    31
    Views
    1,724

    Clueless

    Much like any profession the example of the two childhood friends who are teacher are exactly the type of teachers that set the stage for the type of banter going on here.

    Listen I stand up for...
  18. Replies
    31
    Views
    1,724

    Federal Mandated Curriculm

    You really haven't figured anything out... your clueless! The unions don't control your district, the teachers.... Not the High Paid Administrators ...Nurses,Counslers,Principals, Ect...

    If it...
  19. Replies
    31
    Views
    1,724

    yada yada

    You couldn't get me to baby sit 30-40 + kids everyday for 50-60K a year...
    It's about time these complaining bastards realize they need to be responsible for thier
    sons and daughters... start the...
  20. Thread: Rheem manuals

    by AllTemp
    Replies
    6
    Views
    5,103

    Thanks ...

    Not sure which address that would be John, appreciate the help.... Current is
  21. Thread: Rheem manuals

    by AllTemp
    Replies
    6
    Views
    5,103

    Rheemote.net

    Cannot log into Rheemote.net , link keeps saying need user id/passowrd... So I click log in problems it emails me my password but not login...

    Need specification for a REAB1415J, if someone could...
  22. Thanks Marvin, I appreciate the information, Mel

    Thanks Marvin, I appreciate the information, Mel
  23. Holly/ Fraser Johnson AGP6-60-100-1 serial #1000853

    One of our tech condemned this old girl and drew out the duct lay out and assumed it had reverse RA/SA ...

    Homeower has stated she has 3 qoutes from other companies that claim this unit does not...
  24. Replies
    35
    Views
    9,058

    WITH THE NEW REGULATIONS SOON COMING These...

    WITH THE NEW REGULATIONS SOON COMING

    These caps are the TRICK!
    http://www.noventcaps.com/

    http://www.noventcaps.com/images/workParts.jpg
  25. Pegleg RIP My Friend!

    I am deeply saddened by this news, I didn't know Joe as well as most. I met Joe a few times around the nieghborhood, he was an excellent refrigeration mechanic and knew his way around!




    ...
  26. Replies
    6
    Views
    828

    Using Gas as Aux heat witha heat Pump

    Whats any ones thoughts on using a gas fired furnace as Aux Heat with a Heat Pump? Do not have the ac power to run Aux electric heat strip.. located East Texas. Could one put a short time delay on...
  27. Replies
    27
    Views
    15,893

    Artic ...

    Last time I check it is spelled Arctic, I know of Arctic Mechanical, Inc. in Corona been in buisness for 40 years...

    http://www.arcticmechanical.com
  28. Replies
    31
    Views
    2,286

    Hacker Alert

    Beware Salt Lake Utah, You have a new Craftsman in Town. And he has his own cuttin torch..... he is gona show them how to Braze and Charge his unit to match his cold beer........... East Texas will...
  29. Replies
    31
    Views
    2,286

    No Worries

    No Worries Dangling Wrangler ...

    This individual is 1500 miles away but he frequents this forum often for solutions to his hacker and know he'll enjoy the eye opener if he pays close attention...
  30. Replies
    31
    Views
    2,286

    Proffesional Vs. Hack

    What would you call a guy who uses a compound gauge that is stuck on 250 that also claims you don't need to know all that sub cooling /superheat crap. A good seasoned service tech can charge a...
  31. Thread: Long Line sets

    by AllTemp
    Replies
    6
    Views
    1,159

    huh?

    Have been a member of this forum for a great many number of years, as a matter of fact since it started. I'm still amazed at the intelligence that is displayed:confused:
  32. Thread: Long Line sets

    by AllTemp
    Replies
    6
    Views
    1,159

    Long line sets

    Texas Tec
    This is Pete Mels brother. all the temps have been taken in line with goodman specs. this unit replaced a exsisting unit that was not 13 seer, we do have a temp problem in the attic...
  33. Thread: Long Line sets

    by AllTemp
    Replies
    6
    Views
    1,159

    Sub Cooler

    As Pete menitioned in his original post it is utilizing a TXV, the benifit of strapping the 3/8 liquid line next to the return (suction) for a few feet it would be a subcooler ( primitive) but I...
  34. Thread: Long Line sets

    by AllTemp
    Replies
    6
    Views
    1,159

    Long Line sets

    Hello Group,:)
    Name here is Pete This is My brothers user name I am a rookie at this, He is unavailable............. Have a question. Have a 2 1/2 Goodman 13 seer with a matched indoor unit straight...
  35. Replies
    25
    Views
    2,444

    EAC Cell Replacement

    We had two Trion EAC's in our home and finally heeded to some of the warnings of their Ozone output an elected to use Honeywell F50 models in them.. For me the 20x25x4 fit perfectly.

    With...
  36. Replies
    16
    Views
    1,932

    Laundry Residue's!

    I have seen heavy use of fabric softeners in the laundry room near the FAU along with detergents and the like have lead to premature faulure. Dryer lint especially can be a culprit.

    It doesn't...
  37. Replies
    10
    Views
    1,169

    Banned - Geeeez I'm have Charter Memebrship

    :D

    I'm lurking ...

    I was the 28th member to sign on...
  38. Replies
    115
    Views
    14,367

    North State Tools

    http://www.northstate.com/ridgid/media/rgstart0803.jpgI had already ordered my 1st SeeSnake before I ever read this thread from North State Tools . Prompt delivery for the SeeSnake but the extension...
  39. Replies
    115
    Views
    14,367

    DownLoad SeeSnake

    Depends on the model of your SeeSnake, they have different models. You would want the one that will uplaod to a PC and copy to a DVD... A bit more csotly than the ones these guys are fighting...
  40. Replies
    115
    Views
    14,367

    North State Tools $211.00

    I have been buying from this distributor for many years. Thier about the best price with prompt shipping and always with email followups on your order.

    They are listed on Rigids website as an...
  41. Replies
    115
    Views
    14,367

    SeeSnake Arrived

    It's night and day from my Fiber Optic Testo Scope.....AWESOME

    This thing came bagged in a really nice passed Cordon Bag with the assesories and it's clarity is fantastic.... Dam thing is actually...
  42. Replies
    115
    Views
    14,367

    Testo vs SeeSnake

    I have owned the Testo for quite some time and have relied on it too many times to remember; sending it behind a limit in a furnace up to peek at a dirty coil. But I always hated the part of having...
  43. Replies
    19
    Views
    1,553

    Yeppers...

    Ya think SOOOoooo?
  44. Thread: Superheat

    by AllTemp
    Replies
    14
    Views
    2,054

    Super Heat

    Super Heat is a real hot day in Southern California, right?

    13 years in the buisness and still putting them filters in upside down are we?

    Comon who needs to nkow about Super Heat anyway, these...
  45. Replies
    10
    Views
    3,762

    Re: re phosgene

    Whats the 523 going to do that you can't do with that manifold?
  46. Got To Love The Weather

    112 - 116 over the week end sure glad it's cooling down a bit here...:-)
  47. Replies
    5
    Views
    14,717

    Re: Here feel free to use mine...!

    Not sure if this is the program your looking for try here http://design2fab.com
    http://www.design2fab.com/Products/EntryFormSRsmall.jpg
  48. Replies
    5
    Views
    14,717

    Here feel free to use mine...!

    http://alltemp-hvac.com/duct.gif
  49. Replies
    7
    Views
    1,097

    Nextel

    I've been using Nextel for years and have had their wireless card for about 2 years now... Just upgraded to the Sprint card, pretty happy with it....

    And being on an unlimited usage plan with our...
  50. Replies
    16
    Views
    1,680

    Re: Re: call electrician

    If you've a clamp type amp probe check and see what the current is at the time it trips...

    Breakers weaken over time as do fuses...
Results 1 to 50 of 823