  1. Thread: Y199AAA-2

    by union boy
    Replies
    6
    Views
    1,170

    Hey Heavy, Any chance I could get a copy of that...

    Hey Heavy, Any chance I could get a copy of that JC y199 AAA-2 service manual?
    Thank you in advance.
  2. Replies
    12
    Views
    1,372

    power flame high fire purge proof?

    Can anyone tell me what the part is, the switch that proves high fire purge.
    Im trying to explain this to the counter person. They need part # the job is an hour away.
  3. Replies
    3
    Views
    1,185

    I have several. shoot me e mail,

    I have several. shoot me e mail,
  4. Replies
    3
    Views
    1,185

    are you still looking for sbc vav ya ?

    are you still looking for sbc vav ya ?
  5. Replies
    6
    Views
    693

    Thanks again guys.

    Thanks again guys.
  6. Replies
    6
    Views
    693

    I have checked the sit and only found user manual...

    I have checked the sit and only found user manual and nothing for advanced menue
    I can wait until monday and call our rep. I just put munchkin in to heatthe infloor heat in my garage. this was the...
  7. Replies
    6
    Views
    693

    HW TH5110D1006 Advanced menue??

    Hey any one know how or if you can access the advanced menue on this T stat
    it is in cooling only mode. Need heating mode to display
    This is non programmable stat
  8. Thread: 30GXR135

    by union boy
    Replies
    45
    Views
    4,019

    Just evacuated both circuits last week. 1st cir....

    Just evacuated both circuits last week. 1st cir. down to 350 microns, 2nd down to 300
    held both for over15 min. weighed back in refrigerant.
    last fall i have filled with nitrogen and tracer gas for...
  9. Thread: 30GXR135

    by union boy
    Replies
    45
    Views
    4,019

    30gxr 135

    I will try to answer all you're questions.
    I do not know what exv is used, it is in the economizer.
    The dye used is unknown was (red in color)
    why the customer turns off all power to unit during...
  10. Thread: 30GXR135

    by union boy
    Replies
    45
    Views
    4,019

    Anyone know the tork spec of the motor terminals...

    Anyone know the tork spec of the motor terminals ?
    That is one thing I never done yet.
    I have leak checked them but not checked the tork
  11. Thread: 30GXR135

    by union boy
    Replies
    45
    Views
    4,019

    30gxr 135

    I have checked the packings and all other fittings several times.
    Even had other guys check for leaks.
    This must be leaking out the high side. or vapor leak during low anbiant conditions.
    Sorry...
  12. Thread: 30GXR135

    by union boy
    Replies
    45
    Views
    4,019

    Last spring I replaced the O-Rings on the...

    Last spring I replaced the O-Rings on the compressor suction valve (upper and lower) both circuits.
    Removed chiller ends, leak checked tubes and sheets.
    The threaded fittings on the oil seperator...
  13. Thread: 30GXR135

    by union boy
    Replies
    45
    Views
    4,019

    30gxr 135

    I find it hard to believe that I have the only chiller that loses all the refrigerant out of both circuits through the winter months.
    I have called our carrier rep. several times,
    Last...
  14. Thread: 30GXR135

    by union boy
    Replies
    45
    Views
    4,019

    30gxr 135

    Still having the same problem.
    Lost all of the holding charge over the winter months.
    Any ideas>
  15. Thread: 30GXR135

    by union boy
    Replies
    45
    Views
    4,019

    The reason I changed the oil was to get rid of...

    The reason I changed the oil was to get rid of all the dye Carrier had pumped into it. I hate that crap.
  16. Thread: 30GXR135

    by union boy
    Replies
    45
    Views
    4,019

    30gxr135

    Once again this srping both circuits were flat. I lost all my holding charge.
    Last spring I replaced the O- Rings under the compressor suction flange thinking this may help.
    Called the Carrier Rep...
  17. Replies
    16
    Views
    2,684

    I have seen this before, several times. low...

    I have seen this before, several times.
    low super heat or flood back will wash out the back bearing.
    I suggest replacing the compressor ASAP or it will die of a slow death
    sending metal shavings...
  18. outdoor wood boiler

    I did make my own outdoor wood boiler,It works great.
    I had our shop roll 1/4 inch plate 4'x4' 3'x4' fire box,
    controlled by American Auto-matrix controls.
    I can give you IP you can view all the...
  19. Replies
    8
    Views
    1,415

    Reliable controls

    Do you need A program to access these controls via Phone line?
    Or can you use hyperterminal.
    Thanks Union Boy
  20. hey don't listen to the other guys, we all need...

    hey don't listen to the other guys, we all need help some time.
    I would look for voltage drop on startup low voltage and line voltage.
    I'll bet the breaker tripps due to short cycling of...
  21. Thread: RSES Members

    by union boy
    Replies
    27
    Views
    3,068

    RSES Members

    took the cm exam 1989 30 people and only two passed.
    My college instructor really was proud.
    my employer has no idea what it is.
  22. Replies
    3
    Views
    538

    Rapid Air Unit with vav boxs

    He did say with bypass. but still it would be the first for me also.
    usally they are for makeup air?
  23. Replies
    341
    Views
    43,679

    Should I go union? negatives and positives?

    I have worked both union and non union all i can say is, if you could see my retirement anuity you would agree its a good thing.
    I started with nothing and have a lot more to show for it.
    Gregg
  24. Replies
    1
    Views
    1,555

    good red neck joke

    what does it mean when you see a red neck drewling from both sides of his mouth.
  25. Refrigeration & Ice Making > If U Knew What Was Wrong You Would Do Hvacr U Idiot!!!!

    Had a call to a local machine shop to work on 20 hp air dryer. real piece of sh*t. Standing there amaized at all the jumpers installed acrossed the safety
    controls. maintenance man walks up and just...
  26. Replies
    47
    Views
    5,622

    water in freon

    using nitrogen between evacuations will speed up the process.
    it is cheep and time is money.
    union boy
  27. Thread: smell

    by union boy
    Replies
    25
    Views
    2,414

    “Dirty Sock Syndrome?”

    Check out this link below and others like it
    it may help you out.
    Gregg Livermore
    service supervisor
    climate river valley
    rock island IL
  28. Replies
    2
    Views
    893

    30gxr135 screw

    That is a good point, i will remove some liquid from the bottom of the cooler.
    and see what happens.
    Thanks Gregg
  29. Replies
    339
    Views
    45,938

    Davenport Iowa wow 20 yrs in this biz. work on...

    Davenport Iowa
    wow 20 yrs in this biz.
    work on stuff you kneel down to or things you walk into.
    nobody ever gave me anything.
    and never kissed anyones ass.
    life is good
  30. Replies
    2
    Views
    893

    help with 30gxr135 screw

    Problems are: Carrier 30gxr135 ver. 4
    Unit trips on low suction saturation temp circuit A
    circuit B looks good. 2 deg aproch and 7 deg delta T
    Pretty sure its not low gas.
    suction pressure hunts...
  31. Thread: Thermocouple

    by union boy
    Replies
    14
    Views
    1,819

    look for the eco either in the draft deverter or...

    look for the eco
    either in the draft deverter or next to the heatexchanger.
    and they just dont go bad.
    find the cause of it tripping. ie neg. building pressure
    for the draft deverter
    or high...
  32. Thread: 30GXR135

    by union boy
    Replies
    45
    Views
    4,019

    30gxr135

    Pumped down? not 100% sure but if not i would expect to
    possible lose half of the charge??
    I do agree with the vapor loss.
    for some reason it only leaks during low ambiant conditions.
  33. Thread: 30GXR135

    by union boy
    Replies
    45
    Views
    4,019

    30gxr

    not lately but that is a good idea.
    I know that there is no oil in side the pecker head.
  34. Thread: 30GXR135

    by union boy
    Replies
    45
    Views
    4,019

    30GXR

    Oil level seams ok at this time.
    I changed the poe oil last spring
    same amount in and out.
  35. Thread: 30GXR135

    by union boy
    Replies
    45
    Views
    4,019

    30GXR135

    I have contacted Carrier. Found out they have been working on the same unit and could not find the leak either.
  36. Thread: 30GXR135

    by union boy
    Replies
    45
    Views
    4,019

    30GXR135

    These are 06n compressors.
    The chilled water side is capped off during winter and filled with anti-freeze.
    this is done by the owner.
    Disconnect is turned off also.
    I have pulled off end plates...
  37. Thread: 30GXR135

    by union boy
    Replies
    45
    Views
    4,019

    Where is all my R 134A going ? Here is the...

    Where is all my R 134A going ?
    Here is the story.This machine runs great all summer,
    come spring all refrigerant 350lbs gone there is 175lb in
    each circuit and both are empty.
    This year I remover...
  38. Replies
    18
    Views
    4,021

    Is a stuck 06n compressor good for any thing ? I...

    Is a stuck 06n compressor good for any thing ?
    I just replaced this compressor. No core requested back.
  39. Replies
    11
    Views
    1,695

    caryle 06D

    You should check the net oil pressure. actual oil pressure
    from the oil pump less the suction press. will give the net oil press. It depends on the vintage I would expect 25-40 psi net. you are...
Results 1 to 39 of 39