Search:

Type: Posts; User: 71CHOPS

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    8
    Views
    172

    how do all these compare to a sling...

    how do all these compare to a sling psychrometer?:whistle:
  2. Thread: tool bag

    by 71CHOPS
    Replies
    19
    Views
    729

    my tool bag hasn't left the van for I don't know...

    my tool bag hasn't left the van for I don't know how long.....too much stuff in it for pm's.

    i just toss what i need in a bucket and go......easy to rope up to the roof, and you can just toss any...
  3. yeah, i know, i was really answering mrtoon's...

    yeah, i know, i was really answering mrtoon's post more than anything.
  4. Replies
    11
    Views
    327

    I use the FPST4 for SH and SC. Get the larger...

    I use the FPST4 for SH and SC. Get the larger clamp, or insulate the smaller one when you use it.....just calibrate it every few months, and good to go.

    I use my 5c56 to check OA, or duct...
  5. if you don't COMPLETELY RINSE any cleaner away,...

    if you don't COMPLETELY RINSE any cleaner away, it will end up bad....eventually.

    you shouldn't see ANY soapy bubbles coming off a coil when done rinsing.
  6. Replies
    13
    Views
    468

    just put some pressure to it and pray it with...

    just put some pressure to it and pray it with soap bubbles......as long as this thread has been goin, the leak could have been found and repaired.
  7. Replies
    36
    Views
    1,215

    also, refrig. oil begins to vaporize below...

    also, refrig. oil begins to vaporize below 100-150 microns......if any is in the tank or lines, you could be seeing that.
  8. i would report it to the fire inspector. only...

    i would report it to the fire inspector. only just to CMA in case some thing does happen.....you were the last guy that looked at it.
  9. Replies
    31
    Views
    1,439

    you're automatically assuming a leak....and...

    you're automatically assuming a leak....and that's possible. but it is equally possible that someone let the charge out. kids getting high, or pissed off perp.

    I'd bet leak too.....BUT, there is...
  10. Thread: How come?

    by 71CHOPS
    Replies
    27
    Views
    2,089

    because the installers thought you are an...

    because the installers thought you are an A-hole!!!
  11. Replies
    9
    Views
    357

    there are a few companies that make pelican type...

    there are a few companies that make pelican type cases.....they aren't nearly a proud!!LOL
  12. Replies
    31
    Views
    1,439

    use a vacuum gauge like the bluvac....you'll know...

    use a vacuum gauge like the bluvac....you'll know immediately if you have a leak...tiny or not.
  13. Replies
    16
    Views
    612

    manifold really has nothing to do with vacuuming...

    manifold really has nothing to do with vacuuming a system. should really only be the pump, the hoses, some core tools, and the gauge.
  14. Replies
    29
    Views
    2,654

    ok, i don't get it....what's the motivation? ...

    ok, i don't get it....what's the motivation? gotta be some kind of code for replacing equipment or something?? leave existing, and everything is hunkydorry???
  15. Replies
    49
    Views
    1,866

    I'll be interested to see what they say. over...

    I'll be interested to see what they say. over the last few weeks, I've had no luck with tech support knowing what exists in the equipment their company sells.:gah:
  16. Replies
    16
    Views
    612

    your micron gauge should be as far away from the...

    your micron gauge should be as far away from the pump as possible. Also, it's faster to get rid of the gauges and use core tools, and a vacuum tree on your pump.

    they sell that because, like...
  17. Replies
    49
    Views
    1,866

    there was an article in the RSES journal about...

    there was an article in the RSES journal about VRV testing.....they broke down the number of molecules that escape under pressure vs. under vacuum. good article.....pressure doesn't win over vacuum!
  18. Replies
    49
    Views
    1,866

    if you're dealing with minisplits, that could be...

    if you're dealing with minisplits, that could be your problem.......alot of manufacturers are recommending the eccentric flare tools, not the "old standard".
  19. Man, I'll buy a tester for econs!! I run into...

    Man, I'll buy a tester for econs!! I run into old crap, and new.....it'd be AWESOME to be able to plug-n-play with them.......rather than jumper and add resistors etc. let me know when it's ready,...
  20. Replies
    54
    Views
    3,753

    i know guys WITH a license that are on the same...

    i know guys WITH a license that are on the same level as that guy.
  21. Thread: Sc56?

    by 71CHOPS
    Replies
    10
    Views
    573

    finally found a downside with my 56 today. had...

    finally found a downside with my 56 today. had to connect the anamometer head using the leads....and the readings were severely lagging from real time. it took a LONG time for the reading to rise...
  22. what's the problem? shutoff valves, pop-off...

    what's the problem? shutoff valves, pop-off valve piped to floor, and correct size wire......looks good to me!
  23. Thread: Sc56?

    by 71CHOPS
    Replies
    10
    Views
    573

    love mine.....but yeah, the autorange feature...

    love mine.....but yeah, the autorange feature will slow any good readings.....even on the 56.
  24. Thread: vacuum hose

    by 71CHOPS
    Replies
    16
    Views
    1,316

    I completely understand and agree.....BUT....My...

    I completely understand and agree.....BUT....My vacuum gauge isn't connected to the hoses when checking the system.....so their leak rate is a non issue.

    I've never had a problem pulling below...
  25. Replies
    14
    Views
    1,491

    DUUUHHH!!!:cheers:

    DUUUHHH!!!:cheers:
Results 1 to 25 of 500