Search:

Type: Posts; User: elevatedvagabond

Page 1 of 5 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    3
    Views
    346

    Snupy... C'mon!!! ;) It's been 88* + here the...

    Snupy... C'mon!!! ;)
    It's been 88* + here the last 5 days!!!
  2. Replies
    3
    Views
    346

    OBX HVAC Work

    I am looking for somebody who wants year round work, and understands craftsmanship. We are located in Kitty Hawk, and would love to have somebody from this site apply
  3. Replies
    39
    Views
    1,351

    I wouldn't hold my breath waiting on the...

    I wouldn't hold my breath waiting on the engineers..... Even more so if they were the ones fixing it!
  4. Replies
    39
    Views
    1,351

    Well put!

    Well put!
  5. Replies
    39
    Views
    1,351

    That is good to hear about the warranty as that...

    That is good to hear about the warranty as that is what the customer is adamant about, and the price I was quoted over the phone is reasonable, and should be workable... I am interested in seeing...
  6. Replies
    39
    Views
    1,351

    @ Dave... Did you use Virginia Air in Chesapeake?...

    @ Dave... Did you use Virginia Air in Chesapeake? That is the distributer that I will be speaking with a TM from on Tuesday.
  7. Replies
    39
    Views
    1,351

    @ JT... Do you deal with the labor warranties?...

    @ JT... Do you deal with the labor warranties? How are they?
  8. Replies
    39
    Views
    1,351

    @ NCHeat... Where are you out of? OBX here,...

    @ NCHeat... Where are you out of? OBX here, that's one of my big concerns, the corrosion on these units
  9. Replies
    39
    Views
    1,351

    Wow Dave... They left a bad impression on you!...

    Wow Dave... They left a bad impression on you! What were the problems that you would encounter with York? Manufacturing? The parts they use? Price?
    I really don't know a damn thing about these...
  10. Replies
    39
    Views
    1,351

    10 year parts warranty though, right? And a cheap...

    10 year parts warranty though, right? And a cheap labor warranty... Which kinda makes me wonder.
    Why don't you guys install York? Because of that one job?
  11. Replies
    39
    Views
    1,351

    Thoughts on York Heat Pumps

    I have a customer who wants York equipment put in a condo complex. Any experience that I have with York, i do not recall... Meaning I don't have much....
    However, I set up a meeting with the TM for...
  12. Just study the psychometric chart man... No...

    Just study the psychometric chart man... No matter any explanation, that will make it the most clear to you. It did for me
  13. Replies
    3
    Views
    450

    Hey Ryan... This place is a wealth of knowledge,...

    Hey Ryan... This place is a wealth of knowledge, visit often. I'm on the OBX as well man, great place to be in this trade... Best of luck.
  14. I happen to agree with Miami Mike, Side jobs are...

    I happen to agree with Miami Mike, Side jobs are killing it for all of us. However, it is something that we will need to deal with as tech's/installers will always do it.
    My response to your...
  15. Replies
    23
    Views
    1,836

    I agree!!! Walt, that is sweet! I would love to...

    I agree!!! Walt, that is sweet! I would love to see a close up of how you have your jugs restrained.
    Wow... That doesn't sound right!
  16. Replies
    23
    Views
    1,836

    Footnote: being a shortbed has hindered the side...

    Footnote: being a shortbed has hindered the side boxes and behind the cab box, and has really cut my bed down too much. I don't see that as a valid option, but may be wrong. If anyone has this setup...
  17. Replies
    23
    Views
    1,836

    Thanks for all the input guys. I am leaning...

    Thanks for all the input guys. I am leaning towards an ARE cap. My original intent was a utility bed, but not quite sure that is the better option now. A van was never really an option due to the...
  18. Replies
    23
    Views
    1,836

    Pick up truck for service?

    I have read the other posts on this subject, but really haven't got what I'm looking for yet. I have a crew cab short bed Chevy 1500. I can't seem to get it setup like my van was. A van is not an...
  19. That's the one!!!!

    That's the one!!!!
  20. @Klee... That is true. A lot of mfgr's are using...

    @Klee... That is true. A lot of mfgr's are using 3rd party warranters (if that's even a word). I think it ING, or some 3 letter company. It is also OUTRAGEOUSLY priced, so not sure there will be many...
  21. @ Jim.... Not out of luck... Only out the labor,...

    @ Jim.... Not out of luck... Only out the labor, but it's my folks anyway! I'm with ya man... I don't think Trane will do anything, but I will do my darnedest to get them to help. Worst case...
  22. Replies
    1
    Views
    374

    Constant torque until duct is fixed.... TAM8 is...

    Constant torque until duct is fixed.... TAM8 is not something that is fooled easily, nor should it be... It is an expensive piece of equipment. Constant torque and fix the duct...
  23. Trane extended warranty pickle... Any thoughts?

    I have contacted Trane about becoming a dealer, but they are not taking on any new dealers in my neck of the woods at this time. Years ago, my parents bought the extended warranty through a company...
  24. Replies
    54
    Views
    2,802

    I told the homeowner about that, he said he would...

    I told the homeowner about that, he said he would take care of it. I'm trying to get him on a PM. In that case, I would do it free of charge! We shall see
  25. Replies
    54
    Views
    2,802

    FIRED UP!!! Me and the furnace are fired up!!!...

    FIRED UP!!! Me and the furnace are fired up!!!
    Well, I learned how valuable the manometer is outside of TESP readings! Not something I will soon forget. Thanks a bunch guys!!!
  26. Replies
    54
    Views
    2,802

    Thank you all for your help... I didn't feel so...

    Thank you all for your help... I didn't feel so alone after posting here!!! Let's hope this does it... Leaving HD now with some wasp and hornet killer
  27. Replies
    54
    Views
    2,802

    Bees nest!!!!grrrrr!!!!

    Bees nest!!!!grrrrr!!!!
  28. Replies
    54
    Views
    2,802

    I popped off the exhaust flue... And it fires...

    I popped off the exhaust flue... And it fires up... What's next? How in the world do I clean out the flue
  29. Replies
    54
    Views
    2,802

    @Dandy. I just added an email to the profile....

    @Dandy. I just added an email to the profile. Also the M&S#'s are as follows
    M) UGRA-10EZAJS
    S) EJ5D707F159902402
  30. Replies
    54
    Views
    2,802

    @ Doug... That is awesome about the flame sensor...

    @ Doug... That is awesome about the flame sensor fitting snugly into the inducer port. Is there a time/place for this practice? I mean do you sometimes need to ream out this port?
  31. Replies
    54
    Views
    2,802

    You guys rock!!! Thanks for the torrent of...

    You guys rock!!! Thanks for the torrent of replies!!!!
  32. Replies
    54
    Views
    2,802

    Believe it or not guys.... 11 years in the...

    Believe it or not guys.... 11 years in the trade... I have run across 1 boiler, and probably under 12 furnaces.... Including PM's. It's just the way it is around here. I really appreciate ALL of your...
  33. Replies
    54
    Views
    2,802

    @ Joe... I know it's ridiculous that I just put...

    @ Joe... I know it's ridiculous that I just put my hand up to the pipe for a reading, but at that point I felt lost. I will check those readings in the AM. Thanks man
  34. Replies
    54
    Views
    2,802

    I'm with you Gary, plus these folks have never...

    I'm with you Gary, plus these folks have never maintained this appliance, and it is an'01... They purchased the property 5 years ago, so for that long at least....
  35. Replies
    54
    Views
    2,802

    Chuck, I really don't know much about gas...

    Chuck, I really don't know much about gas furnaces.... I do not see them very often. If you can point me in the direction of some good literature, I would be stoked to read it. I am not ignorant on...
  36. Replies
    54
    Views
    2,802

    @408 I feel that the exhaust is sufficient, based...

    @408 I feel that the exhaust is sufficient, based on only my hand against the pipe outside. I know that is a rudimentary way to measure it. But, you have my interest with the secondary heat...
  37. Replies
    54
    Views
    2,802

    Thanks guys... I do not think it is the switch...

    Thanks guys... I do not think it is the switch either. However, my lack of knowledge has me at a standstill. I will hook up the manometer first thing in the AM. I am with Gary and believe this unit...
  38. Replies
    54
    Views
    2,802

    The inducer fan motor fires up, and runs for...

    The inducer fan motor fires up, and runs for about a minute... Then everything shuts down. When I jump around it, everything fires off. Also, Ruud has a diagnostic tree and on board diagnostic tool...
  39. Replies
    54
    Views
    2,802

    That's what I like to hear!!!

    That's what I like to hear!!!
  40. Replies
    54
    Views
    2,802

    @ Daniel, I didn't bust out the manometer. I will...

    @ Daniel, I didn't bust out the manometer. I will find out in the AM if the problem persists. Where is the rating for the pressure located?
  41. Replies
    54
    Views
    2,802

    Gotcha.... Thanks Gary. I will check it out in...

    Gotcha.... Thanks Gary. I will check it out in the AM. It is a dual fuel setup, so I got their Heat Pump working, and got my butt handed to me by the furnace so I left to check in here and try to get...
  42. Replies
    54
    Views
    2,802

    @ Gary... I tried the best I could, but I could...

    @ Gary... I tried the best I could, but I could not get all up in the 'canister' that the 2 hoses are attached to. Also, there was some gunk built up at where the hose attaches to one side. It tee's...
  43. Replies
    54
    Views
    2,802

    I'm LOST on a Ruud 90% Furnace

    Hey guys,
    I went to a call yesterday, and all signs pointed to the vent pressure switch being a failed component. I replaced it, and low and behold still no flame. I put the original back on b/c it...
  44. Replies
    7
    Views
    547

    Thanks guys... I spoke to my FSR and he keeps...

    Thanks guys... I spoke to my FSR and he keeps pushing the TAM7... I really do appreciate it.. Big thanks to you Loonie for checking Comfortsite!!!
  45. Replies
    7
    Views
    547

    A monkey wrench in the works too... It's a...

    A monkey wrench in the works too... It's a 2TEE... Now, converting that will not be an issue, but I do wonder about the match... What do you think, make a lick of difference???
  46. Replies
    7
    Views
    547

    The smaller coil doesn't concern you pairing it...

    The smaller coil doesn't concern you pairing it with the 16i?
  47. Replies
    7
    Views
    547

    I, too, would love to see the TEE return. The...

    I, too, would love to see the TEE return. The TAM's are overkill!! The GAM's, I've noticed, have done away with ALL boards and EEV's... But still have no ECM, and the GAF's and TEM's are just cheap...
  48. Replies
    7
    Views
    547

    Trane XL16i question

    I have the opportunity to get some very slightly used XL16i 2 Ton heat pumps, with some older style (4TEE) model AHU's. One will be matched to a 4TEE3F40, and the other AHU that I have available is a...
  49. Replies
    33
    Views
    2,565

    This thread is quite insulting to those of us in...

    This thread is quite insulting to those of us in the field man....
  50. Replies
    14
    Views
    1,467

    It would be hard to justify diagnosing a bad TXV...

    It would be hard to justify diagnosing a bad TXV on a subcooling reading alone. If the pressures were within realm and the subcooling was off by 3*f (remember that mfgr's often add +/- 3*f to a...
Results 1 to 50 of 247