Search:

Type: Posts; User: nvr2old

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    6
    Views
    377

    condenser/compressor is 20' below evap and 45'...

    condenser/compressor is 20' below evap and 45' total refrigerant line length.
  2. Replies
    6
    Views
    377

    suction line trap

    Hope this is correct forum. We're installing a split wine unit for wine room. The refrigerant piping instructions call for a trap in suction line half way up between condenser and evaporator. The...
  3. Thread: Hot tub room

    by nvr2old
    Replies
    4
    Views
    735

    How can the exhaust fan be to big or small if its...

    How can the exhaust fan be to big or small if its controlled by humidistat? It runs as long as it needs to. How can you ever keep the joists from sweating if the room is always cold and the he pops...
  4. Here's an install question. If your furnace...

    Here's an install question. If your furnace opening is 23x14 and you 5 inch filter rack is 20x25 do you make a transition or do you butt the rack up against the furnace and blank off the excess...
  5. Yes it lowers static on the return side...

    Yes it lowers static on the return side significantly. Its worth it. Just remember the static will go up on supply side if duct is to small. One of the ACCA alphabet manuals recommends you choose a...
  6. Are you looking to just lower static to be in...

    Are you looking to just lower static to be in factory specs or to achive a cfm at a certain static, or as much cfm as possible?
  7. Gas or fan coil. Install one long common plenum...

    Gas or fan coil. Install one long common plenum on return side. Buy 5' rex racks and rex plenums from Insco. Install as far back on common plenum as possible. Attach duct to rex plenum. I cant see a...
  8. Replies
    29
    Views
    1,369

    We have an H10, D-Tek Select, and a SLR-2...

    We have an H10, D-Tek Select, and a SLR-2 Fieldpiece. The H10 does as well on 410 as any, maybe slightly better. The D-Tek because of its poor battery life comes in third. The Fieldpiece we just got ...
  9. Replies
    8
    Views
    574

    You need a contractors license which requires 3...

    You need a contractors license which requires 3 years verifiable field experience. Then you get to buy insurance.
  10. Replies
    8
    Views
    574

    What do you mean by certified tech card?

    What do you mean by certified tech card?
  11. Replies
    22
    Views
    1,311

    Cordless drills.

    Cordless drills.
  12. Replies
    47
    Views
    3,085

    I called GE awhile back needing a part for my gas...

    I called GE awhile back needing a part for my gas clothes dryer. They would not sell it to me because I was not a licensed plumber. A liability issue. Not every manufacturer is as smart as GE.
  13. Thread: Pumpkins

    by nvr2old
    Replies
    4
    Views
    511

    I'm wasn't necessarily asking for the definitive...

    I'm wasn't necessarily asking for the definitive answer with details provided, just wandering if there is a possible problem, or does a care facility of this type have more IAQ problems than my house...
  14. Thread: Pumpkins

    by nvr2old
    Replies
    4
    Views
    511

    This is not a trick question.

    This is not a trick question.
  15. Thread: Pumpkins

    by nvr2old
    Replies
    4
    Views
    511

    Pumpkins

    What happened to my pumpkin? I bought 2 identical pumpkins several weeks before Halloween and decorated both with push in wood decorations only, not carved. One pumpkin went to Grandsons house as is...
  16. Replies
    15
    Views
    2,453

    Why do some Inficon D-teks work better than...

    Why do some Inficon D-teks work better than others. Our D-tek will only find a 410 leak once the H-10 points it out. I don't like the Inficon batterys. When will they go to a lithum battery? Our...
  17. Replies
    14
    Views
    1,282

    Tell him you want a metal, externally insulated...

    Tell him you want a metal, externally insulated plenum.
  18. Replies
    37
    Views
    1,576

    Call your chosen manufacturers technical...

    Call your chosen manufacturers technical service/applications department when in doubt.
  19. Replies
    22
    Views
    1,486

    Forget the vehicle wrap, most are to complicated...

    Forget the vehicle wrap, most are to complicated to read. Clean and neat works better. Don't let your wife quit her day job. Sign up with Mitsubishi, free advertising that actually works.
  20. Replies
    6
    Views
    443

    So you have a 5 ton in an upflow position? Is it...

    So you have a 5 ton in an upflow position? Is it in a closet with the only return space being under the unit or do you have a pier and beam house with a ducted return system. What size was your...
  21. Thread: lennox

    by nvr2old
    Replies
    4
    Views
    358

    You gotta be an electrical engineer to read them.

    You gotta be an electrical engineer to read them.
  22. A/C Harris, hanging a unit is not manditory in...

    A/C Harris, hanging a unit is not manditory in Dallas
  23. I wish every attic was as neat and pretty as the...

    I wish every attic was as neat and pretty as the ones in the quick sling ad.
  24. Thread: lennox TXV

    by nvr2old
    Replies
    9
    Views
    796

    They have adjustable ones in the catalog also if...

    They have adjustable ones in the catalog also if you prefer.
  25. Replies
    9
    Views
    1,583

    Call the Lennox 800 number. Explain the situation...

    Call the Lennox 800 number. Explain the situation nicely and ask for help. Any Lennox dealer that gives a hoot can get your motor comped.
Results 1 to 25 of 491