Search:

Type: Posts; User: troyport

Page 1 of 5 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    8
    Views
    303

    He's looking into it, will have an answer on...

    He's looking into it, will have an answer on Monday. I was trying to cover all my bases with the "selling on my own" question, and I think my guy was just trying to cover his butt if they don't let...
  2. Replies
    8
    Views
    303

    Thanks for the reply hvacvegas. So far has that...

    Thanks for the reply hvacvegas. So far has that CTK04 proven to be a reliable unit? My tech tells me he may only be able to swap the CTK02, so if I want the CTK04 I will have to buy it and try to...
  3. Replies
    8
    Views
    303

    Hello all, I looked at the the literature on the...

    Hello all, I looked at the the literature on the the CTK04, and it does add some features that I would like over the CTK02. But does the CTK04 still allow the same programming of the fan speeds, fan...
  4. Replies
    8
    Views
    303

    Thanks for the replies. What would I gain with...

    Thanks for the replies. What would I gain with the 04 or even the 03 over the 02?
  5. Replies
    8
    Views
    303

    upgrading t-stat advice.

    My current goodman CTK-02 is being replaced under warranty, due to a bad back up battery. (see other thread) However, I might be able to get partial credit for it and get a different t-stat. I wish...
  6. Replies
    3
    Views
    166

    Corroded back up button battery with no markings...

    Corroded back up button battery with no markings soldered to the board. Not really homeowner-friendly. My tech will swap the t-stat, no problem.
  7. Replies
    3
    Views
    166

    Okay, thanks. I was looking in the user manual...

    Okay, thanks. I was looking in the user manual for instructions on changing the battery, and what battery it is. Since I didn't see a section dealing with this, I assumed it didn't have it. I will...
  8. Replies
    3
    Views
    166

    Goodman CTK02 losing time and date.

    Hi all, I have seen on the last 2 power failures (over the last month) this t-stat has needed the time and date re-entered. The power failures were less than 15 minutes each occurrence. According...
  9. Replies
    1
    Views
    217

    Changing the blower speeds via the tstat gets me...

    Changing the blower speeds via the tstat gets me the same delta t so I am thinking the txv in the outdoor unit is compensating for the different load. I would love it if someone could briefly...
  10. It's back on. Thanks for the advice. Mike

    It's back on. Thanks for the advice. Mike
  11. I should add, the very slight fractional-second...

    I should add, the very slight fractional-second light flicker I get when the HP starts bugs me. Rural area, me and the neighbor share a power transformer, he had a HP hacked-in real bad a few years...
  12. Replies
    1
    Views
    217

    expanded heating data question

    According to the chart for my equipment and my current outdoor ambient temperature, my delta T is a few degrees higher than the chart says. It always is, no matter what the outdoor temperature (I've...
  13. reason for compressor delay on HP defrost

    I have a goodman 2 stage 16 seer HP with a propane GMVM furnace and CTK02 t-stat. What is the reason for a compressor delay during defrost? From my point of view, seems like unneeded compressor...
  14. Replies
    4
    Views
    281

    Can't get past the gate-keeper at Goodman, and I...

    Can't get past the gate-keeper at Goodman, and I was hoping that I didn't need to bug the installer with this kind of question, would rather save him for a real problem. I change the filter without...
  15. Replies
    4
    Views
    281

    I've read that a bunch of times. But this is the...

    I've read that a bunch of times. But this is the first time I have actually comprehended that is says RUN time.. Now I feel stupid. So I suppose that means if I have it set for 1 month, then the...
  16. Replies
    4
    Views
    281

    change filter reminder

    This is too funny.. Goodman GMVM96 with CTK02 t-stat, 2-stage 16 seer HP. I have the change filter reminder set at 1 month and yes, it was turned on. Well, after many months later, the "change...
  17. thanks for the responses..

    thanks for the responses..
  18. many thanks, and one last burning question.

    Hello all.. I have been posting and reading here for many years. The information I gained by all the professionals here has been invaluable. I had a basic propane furnace / old school AC unit when...
  19. new board in HP change the defrost procedure?

    Goodman 16 seer 2 stage HP with modulating furnace and CTK02 t-stat.. from the time it was new, I would get a "No indoor blower" trouble code when coming out of defrost. Finally, Goodman had a fix...
  20. Replies
    2
    Views
    300

    Through the wall unit at a very nice inn

    The Inn at Ohio Northern University, recently completely upgraded including new through the wall HVAC units. When we checked in, the room was cool even though it was set at 75 degrees. Then...
  21. general question for all you professionals..

    Forgive me if this is the wrong place for this post. I was looking at the wall of shame area, came across the HVAC system built by the engineer, and I wonder if any of you add components to your...
  22. Replies
    3
    Views
    419

    Filter is always perfectly clean. But if is was a...

    Filter is always perfectly clean. But if is was a dirty filter and therefore bad indoor airflow, wouldn't that tend to lower the suction and trip out on low pressure?
  23. Replies
    3
    Views
    419

    high pressure trip.

    Goodman 2-stage heat 16 seer heat pump, communicating system. Once in a while, via the t-stat I will check for error codes. Found that over the past 2 months, it has tripped out on high pressure /...
  24. Great news. Thanks for the reply.

    Great news. Thanks for the reply.
  25. That's my question too. Was it just a "shot in...

    That's my question too. Was it just a "shot in the dark to shut the guy up" board or is it a documented problem that now has a verified fix.
  26. I've had the HP for a year, and this is the first...

    I've had the HP for a year, and this is the first time anyone anywhere has ever said anything. Couldn't have a conversation at all, then suddenly Goodman has a new board and tells my tech "problem...
  27. Goodman no indoor blower error code, solved?

    Posted about this before, but no one here was able to offer help, but have helped in so many other ways I thought I would share this:
    3 ton 16 seer 2 stage HP with modulating gas furnace and CTK02...
  28. So is it safe to assume that no one has ever done...

    So is it safe to assume that no one has ever done this? And also no one has ever looked at the network communications as a computer and could benefit from cabling as such?
  29. Any Goodman / Amana guys have thoughts?

    Any Goodman / Amana guys have thoughts?
  30. twisted pair for communication wires, maybe solve occasional communication glitches.

    Goodman communicating system, uses a 4 wire hook up. I saw in the manual that communications can be improved if shielded, twisted pair cable is used for the data lines. So that would mean, as I...
  31. random thoughts after first winter with dual fuel system

    Well, I guess with this winter it might be far from over. Goodman 2 stage 16 seer HP with modulating propane furnace and CTK02 t-stat. Overall, I just love this system. I am amazed how well the HP...
  32. It plugs directly into the board, so not exposed....

    It plugs directly into the board, so not exposed. But probably a bad connection, unless it is a board problem (bad solder joint, hairline crack, etc. I will ask him when it comes out in spring,...
  33. outdoor ambient temp sensor blanking out.

    Goodman 2 stage 3 ton HP, with modulating furnace and CTK02 t-stat. During our first real cold snap about a month ago, below zero outside, come home and the HP is running. I have the dual fuel temp...
  34. Replies
    11
    Views
    811

    I understand.. if it isn't cheaper for you then...

    I understand.. if it isn't cheaper for you then it might as well sit in my garage from your point of view. That makes sense, and I appreciate your honesty. I am in NE Ohio, could this stuff even be...
  35. Replies
    11
    Views
    811

    No clue what it is worth, but I could google it. ...

    No clue what it is worth, but I could google it. Any fair price is better than what I am getting for it sitting in the garage. Can the stuff be shipped without a hassle?
  36. Replies
    11
    Views
    811

    the original nat gas burner and valve for an 80K...

    the original nat gas burner and valve for an 80K Goodman GMVM, never used. The furnace was converted to Propane. And when I bought my house in 1999 it had an R22 AC unit that was not working quite...
  37. Replies
    11
    Views
    811

    can a homeowner sell stuff here?

    Like the subject says..
  38. Replies
    4
    Views
    473

    thank you very much.

    thank you very much.
  39. Replies
    4
    Views
    473

    No picture, and frost was not thick. It was...

    No picture, and frost was not thick. It was probably just starting to restrict airflow, hence the slight drop in temperature rise.
  40. Replies
    4
    Views
    473

    outdoor coil frosting in a pattern.

    Perfect conditions yesterday for frosting of a heatpump. I noticed mine was frosting in a pattern, that eventually filled in almost completely before it went into defrost. When it was completely...
  41. Replies
    8
    Views
    870

    Thanks for the replies. But why was this moved...

    Thanks for the replies. But why was this moved to "tech to tech"? I am not a tech!
  42. Replies
    8
    Views
    870

    propane vs. natural gas

    See a lot of threads here pertaining to this.. But exactly why is propane harder on equipment than natural gas? Never lived in the city, been on propane my whole life, nearly 50 years.
  43. Replies
    15
    Views
    1,103

    Agreed on the 60k, but too late now! Regarding...

    Agreed on the 60k, but too late now! Regarding the ductwork, in my case I am sure that is okay even for the furnace I have, on high fire with proper temp rise, the static pressure in the ducts are...
  44. Replies
    13
    Views
    1,200

    Oh... well, who knows where the heck that little...

    Oh... well, who knows where the heck that little bracket went! So essentially the little sensing bulb is out in the weather, okay, then where it is now is a reasonable place. My installer told me the...
  45. Replies
    13
    Views
    1,200

    I have painted an incorrect picture for you, I am...

    I have painted an incorrect picture for you, I am sorry about that! This HP has a temp sensor on about a 12" lead that plugs directly into the main board of the HP. It is not connected to the...
  46. Replies
    13
    Views
    1,200

    Correct.

    Correct.
  47. Replies
    15
    Views
    1,103

    regardless of how much efficiency I am losing,...

    regardless of how much efficiency I am losing, just the fact that I did my best to get it right really is a bummer. We were not here when the house was built, so, who knows how good the walls really...
  48. Replies
    13
    Views
    1,200

    The wire leads are only about 12" long, no way to...

    The wire leads are only about 12" long, no way to get it too far away from the HP. Maybe this is why it is attached to the electrical flexible conduit.
  49. Replies
    15
    Views
    1,103

    well, it is very comfortable in here, and silent...

    well, it is very comfortable in here, and silent - since the blower never runs very fast. I suppose all I am losing is ultimate efficiency? One thing for sure, I can still use setbacks, even during...
  50. Replies
    13
    Views
    1,200

    Yes, I agree, needs to be outside, but where are...

    Yes, I agree, needs to be outside, but where are they generally mounted? I'm figuring not in direct sun, not where it can pick up temps (warm or cold) from the HP itself, but sheltered from direct...
Results 1 to 50 of 238