Search:

Type: Posts; User: manny238

Page 1 of 10 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    2
    Views
    183

    Lead Compressor contactor aux switch. Check NO...

    Lead Compressor contactor aux switch. Check NO contacts


    Sent from my iPhone using Tapatalk
  2. Replies
    3
    Views
    248

    What download are you looking for ? There is no...

    What download are you looking for ? There is no other tool that will work on Trane VRF.


    Sent from my iPhone using Tapatalk
  3. Replies
    3
    Views
    248

    Are all your units communicating correctly. If...

    Are all your units communicating correctly. If you have any faults the fan will come on then shut off within minutes.


    Sent from my iPhone using Tapatalk
  4. Thread: VRF

    by manny238
    Replies
    91
    Views
    16,673

    Well said

    Well said
  5. Replies
    2
    Views
    353

    You have mail.

    You have mail.
  6. Replies
    32
    Views
    12,175

    Yup every office is different. There is a...

    Yup every office is different. There is a default password but usually it's never used.


    Sent from my iPhone using Tapatalk
  7. Replies
    1
    Views
    1,163

    This alarm is generated when the sensor is...

    This alarm is generated when the sensor is reading out of range. Check your space sensing tube and your outside reference tube. Might be plugged.


    Sent from my iPhone using Tapatalk
  8. Replies
    30
    Views
    2,813

    Bummer I've done that before trying to remove a...

    Bummer I've done that before trying to remove a high pressure relief on a RTAC oil separator.


    Sent from my iPhone using Tapatalk
  9. Replies
    22
    Views
    4,987

    That drain line looks legit Sent from my...

    That drain line looks legit


    Sent from my iPhone using Tapatalk
  10. Replies
    14
    Views
    4,884

    610661610671 I love my tool bag. They used to...

    610661610671

    I love my tool bag. They used to be made here locally in Phoenix but the company went out of business. I have 1 brand new bag on standby. I used the Veto bags for a little bit but...
  11. Should also mute when you make any changes from...

    Should also mute when you make any changes from the gateway.


    Sent from my iPhone using Tapatalk
  12. You can mute remotes or wall sensors through...

    You can mute remotes or wall sensors through your installation code on your indoor unit. Very confusing if you do it from your remote. Very easy if you do it from the commissioning tool.


    Sent...
  13. Replies
    13
    Views
    1,991

    You should check the aux contacts on the circuit...

    You should check the aux contacts on the circuit breaker for the corresponding circuit. I just had one where I would get intermittent compressor trip alarms. Turned out to be the aux contacts behind...
  14. 4 degrees of sh seems kinda low. Could explain...

    4 degrees of sh seems kinda low. Could explain why your seeing some oil foam up.

    Do you have the manual for this unit?


    Sent from my iPhone using Tapatalk
  15. Yes if your water flow was low you would fail on...

    Yes if your water flow was low you would fail on flow switch safety. If your flow switch is operating correctly. You check your flow by recording your delta p across your evap barrel water...
  16. What he said. Make sure to check your water flow....

    What he said. Make sure to check your water flow.


    Sent from my iPhone using Tapatalk
  17. Thread: Wow.

    by manny238
    Replies
    10
    Views
    4,996

    Love the disconnect stand. Lol Sent from my...

    Love the disconnect stand. Lol


    Sent from my iPhone using Tapatalk
  18. Replies
    7
    Views
    1,041

    Very true Sent from my iPhone using Tapatalk

    Very true


    Sent from my iPhone using Tapatalk
  19. Replies
    7
    Views
    1,041

    Evap coil was a microchannel? Sent from my...

    Evap coil was a microchannel?


    Sent from my iPhone using Tapatalk
  20. Replies
    21
    Views
    3,446

    Single phase equipment? Your job looks...

    Single phase equipment?


    Your job looks sweet. Nice job.


    Sent from my iPhone using Tapatalk
  21. Call Copeland? Need to call a real company. ...

    Call Copeland? Need to call a real company.


    Sent from my iPhone using Tapatalk
  22. Replies
    13
    Views
    1,991

    Use some 100 milliamp fuses. These will work as...

    Use some 100 milliamp fuses. These will work as tattle tales. Take a look at your aux switch for your compressor circuit breaker.


    Sent from my iPad using Tapatalk
  23. Replies
    93
    Views
    36,244

    Have u tried contacting Sporlan? All they gotta...

    Have u tried contacting Sporlan? All they gotta know is how many distributors tubes u have and what tonnage is your machine. They can tell you what size of distribution tubes to use and also give...
  24. Replies
    19
    Views
    5,581

    Smardt Chiller Repair - Turbocor

    Smardt had a problem on there first generation chillers where the set screw was coming loose. I know they sent me something about it, id have to check when I get home. The new IGV comes with a new...
  25. Replies
    7
    Views
    1,015

    592261 Sent from my iPhone using Tapatalk

    592261


    Sent from my iPhone using Tapatalk
  26. Replies
    7
    Views
    1,015

    That's a Mcquay model number. Sent from my...

    That's a Mcquay model number.


    Sent from my iPhone using Tapatalk
  27. Replies
    19
    Views
    5,581

    Could not maintain set point. Sent from my...

    Could not maintain set point.


    Sent from my iPhone using Tapatalk
  28. Replies
    3
    Views
    703

    The unit should work in whatever mode you leave...

    The unit should work in whatever mode you leave it in. I don't understand why the unit would only work in auto mode. Do u have the model number of the condensing unit?

    The pump option is turned on...
  29. Replies
    3
    Views
    703

    How long has this system been started up for? As...

    How long has this system been started up for? As far as your cassettes locking out have you checked to ensure the condensate pump is actually working? The pump option has to be turned on when in...
  30. Replies
    2
    Views
    480

    Have you tried running the unit in test mode? ...

    Have you tried running the unit in test mode?


    Sent from my iPhone using Tapatalk
  31. Replies
    19
    Views
    3,649

    Stick to my torches as long as possible. ...

    Stick to my torches as long as possible.


    Sent from my iPhone using Tapatalk
  32. Replies
    35
    Views
    5,009

    Considering a new position. . . .

    ..
  33. Replies
    11
    Views
    1,704

    I was having the same problem. Mine got tied into...

    I was having the same problem. Mine got tied into Trane SC. I had re discover all my units and it took care of my problem. Take in mind I did have a controls tech with me that handled the SC part of...
  34. Replies
    11
    Views
    1,704

    Have you discovered all your units for the Bacnet...

    Have you discovered all your units for the Bacnet controller? Do u see all your fan coils and outdoor units?


    Sent from my iPhone using Tapatalk
  35. Replies
    2
    Views
    601

    On YouTube there is plenty information. ...

    On YouTube there is plenty information.


    Sent from my iPhone using Tapatalk
  36. Replies
    16
    Views
    6,282

    60+ year old Trane Centravac

    Work horse. Good looking machine.


    Sent from my iPhone using Tapatalk
  37. Not much man just trying to keep busy. Haha I...

    Not much man just trying to keep busy.

    Haha I hear that. The general must be losing some hair on this job.

    Is that the job where they overcharged every unit with oil?

    Glad to see your...
  38. What a bummer for new equipment. You should ask...

    What a bummer for new equipment. You should ask for there start up logs for a good laugh.


    Sent from my iPhone using Tapatalk
  39. Replies
    25
    Views
    3,248

    Not so bad when u can park next to the unit. ...

    Not so bad when u can park next to the unit.


    Sent from my iPhone using Tapatalk
  40. Replies
    5
    Views
    1,299

    Check to ensure the compressor u actually have is...

    Check to ensure the compressor u actually have is configured into the UCP control panel.


    Sent from my iPhone using Tapatalk
  41. Replies
    84
    Views
    9,223

    Prolly a recip compressor your installing. I...

    Prolly a recip compressor your installing. I believe it's just another port to your suction side of the compressor. You can either braze it shut or braze a fitting on so u can gauge up there.
  42. Replies
    84
    Views
    9,223

    Why is your boss going back with a 5 ton...

    Why is your boss going back with a 5 ton compressor?
  43. Replies
    84
    Views
    9,223

    X2

    X2
  44. It's nothing audible It's just a red light and...

    It's nothing audible It's just a red light and alarm notice on the unit controller. Doesn't shut down the unit just gives u a warning/alarm that the filters may need service.

    As far as what...
  45. It has a pressure differential switch that looks...

    It has a pressure differential switch that looks at pressure across the filters.
  46. I've had the pins get real corroded on the...

    I've had the pins get real corroded on the control boards and cause all sorts of problems. Just something you might wanna look into. They usually get real discolored as well.
  47. Replies
    84
    Views
    9,223

    Trane compressor not coming on

    Have u tried megging the
    Compressor?
  48. I used to love using bungie cords but in arizona...

    I used to love using bungie cords but in arizona they only last a couple of weeks in the summer.
  49. Thread: Just wow

    by manny238
    Replies
    13
    Views
    3,592

    At least it held for a while. Lol. Just crazy!

    At least it held for a while. Lol. Just crazy!
  50. Replies
    9
    Views
    1,476

    Yeah I try to make it a habit to replace the...

    Yeah I try to make it a habit to replace the check valves and driers if I have any suspicion of a restriction.......Especially on those Carrier package heat pumps with the header metering device.