Search:
Type: Posts; User: jramunni
Search: Search took 0.01 seconds.
-
05-08-2013, 01:45 PM
Thread: Opinions on Emme zoning system...
by jramunni- Replies
- 5
- Views
- 253
If you go to the home owner website you can enter...
If you go to the home owner website you can enter your zip code and pull up contractors in your area that install Arzel
http://www.arzel.com/locate.php -
05-08-2013, 09:17 AM
Thread: Honeywell zoning for basement finish
by jramunni- Replies
- 36
- Views
- 894
Yes...Zoning is usually the best option in that...
Yes...Zoning is usually the best option in that application.
-
05-08-2013, 09:11 AM
Thread: Opinions on Emme zoning system...
by jramunni- Replies
- 5
- Views
- 253
Not sure if these are close but here are a few...
Not sure if these are close but here are a few recommendations...Awesome Services and ATS Mechanical. If you get me your zip code I can get you a few more recommendations that might be closer to you.
-
05-07-2013, 01:56 PM
Thread: Opinions on Emme zoning system...
by jramunni- Replies
- 5
- Views
- 253
Your really not comparing oranges to...
Your really not comparing oranges to oranges...Emme is a much more complex system than Arzel. Emme uses a bladder type duct closure and Arzel uses a gasketed blade, both actuated by low press/vac. If...
-
04-01-2013, 11:42 AM
Thread: zone dampers and hvac balancing
by jramunni- Replies
- 57
- Views
- 1,324
A few options to look into; Arzel "Balance-Pro"...
A few options to look into;
Arzel "Balance-Pro" dampers, insert-able manual balancing damper that can be replaced with an air driven damper if zoning is installed at a later date.
Arzel... -
02-18-2013, 08:50 AM
Thread: Three zone system
by jramunni- Replies
- 8
- Views
- 414
If the two zones being heated by a common forced...
If the two zones being heated by a common forced air system are isolated from each other, than the importance of having functional returns in each zone is critical.
-
02-15-2013, 10:23 AM
Thread: Three zone system
by jramunni- Replies
- 8
- Views
- 414
If the temperature at the thermostat is correct...
If the temperature at the thermostat is correct than why do you want it to run longer?
The middle of the house has much less of a heat loss then the other two and is most likely being heated by... -
01-24-2013, 11:12 AM
Thread: Zone or no zone Basement
by jramunni- Replies
- 16
- Views
- 847
Great application for zoning...if your registers...
Great application for zoning...if your registers will be in the ceiling be sure that you design for max velocity to push the warm air towards the floor.
Our system (available to contractors only)... -
12-17-2012, 10:00 AM
Thread: Arzel HeatPump Pro
by jramunni- Replies
- 2
- Views
- 323
It is actually not an "Error Message" but simply...
It is actually not an "Error Message" but simply a "message" indicating what is happening with the management of the equipment.
"Below Balance Point" can indicate one of two things;
1st- If... -
12-06-2012, 10:51 AM
- Replies
- 14
- Views
- 1,250
I believe you are on the wrong thread...
I believe you are on the wrong thread...
-
12-06-2012, 09:35 AM
- Replies
- 14
- Views
- 1,250
Typically the room by room load diversity will...
Typically the room by room load diversity will remain regardless of where your system is located. You might move the problem to another room or another season by changing delivered air flow...
-
11-20-2012, 09:45 PM
Thread: Ecobee or Nest
by jramunni- Replies
- 42
- Views
- 6,225
The Nest stat is not something to take lightly or...
The Nest stat is not something to take lightly or thumb your noise at...it was well developed and being well marketed. You need to look at it as an opportunity to either help your customer get it...
-
11-20-2012, 08:39 PM
Thread: Ecobee or Nest
by jramunni- Replies
- 42
- Views
- 6,225
You are joking right???
You are joking right???
-
07-05-2012, 04:08 PM
Thread: Multi Zone Options
by jramunni- Replies
- 21
- Views
- 1,258
I sure am glad that I don't perceive that "most"...
I sure am glad that I don't perceive that "most" hvac technicians are like "those guys" that make me crazy when they call in for tech support and don't have a clue about diagnosing a system problem. ...
-
07-05-2012, 03:00 PM
Thread: Multi Zone Options
by jramunni- Replies
- 21
- Views
- 1,258
Do realize that the thousands of systems that...
Do realize that the thousands of systems that have been installed properly and therefore work very well are only seen by the contractors that installed them. Those home owners see their contractors...
-
07-05-2012, 02:29 PM
Thread: Multi Zone Options
by jramunni- Replies
- 21
- Views
- 1,258
We have been working towards "non bypass" designs...
We have been working towards "non bypass" designs for the past 10 years and agree with the CEC study pertaining to bypass ducts as an energy hit.
My opinion is that you should "never" have a... -
07-05-2012, 01:30 PM
Thread: Multi Zone Options
by jramunni- Replies
- 21
- Views
- 1,258
It again comes down to proper application...if...
It again comes down to proper application...if properly applied the results of magic beans is golden!
They really weren't magic...they just led to something that wasn't expected.
The magic of... -
07-05-2012, 12:17 PM
Thread: Multi Zone Options
by jramunni- Replies
- 21
- Views
- 1,258
How do you change the cfm values from htg to clg?...
How do you change the cfm values from htg to clg?
I understand that equipment cfm is different for htg to clg but the cfm ratios to each register is the same unless you re-balance the system for... -
07-05-2012, 11:31 AM
Thread: Multi Zone Options
by jramunni- Replies
- 21
- Views
- 1,258
If you use the wrong zoning control and the wrong...
If you use the wrong zoning control and the wrong bypass and the wrong installer than you will have issues, so don't do that!
In most applications redesigning duct work is not required. If the... -
07-05-2012, 09:49 AM
Thread: Multi Zone Options
by jramunni- Replies
- 21
- Views
- 1,258
Magic it is not...a problem solver it most...
Magic it is not...a problem solver it most definitely can be!
Most things don't work when improperly installed!
"Won't need Zoning"...That's your opinion...Many people want more control than... -
11-28-2011, 10:02 AM
- Replies
- 16
- Views
- 927
Ceiling registers are great for cooling if you...
Ceiling registers are great for cooling if you can optimize the air flow to them when you need it. If you don't close the doors to those 2nd fl rooms the air will make its way to the return air...
-
11-23-2011, 09:08 AM
Thread: Advice on new construction geo system
by jramunni- Replies
- 8
- Views
- 1,049
I read this as two zoned systems with a total of...
I read this as two zoned systems with a total of 7 tons of capacity.
We have many very experienced Geo contractors using our zoning systems with much success.
If sized properly a bypass damper... -
11-22-2011, 03:02 PM
- Replies
- 16
- Views
- 927
If you could possibly pull 100% of the return air...
If you could possibly pull 100% of the return air from the 2nd fl, it might help, but it still won't be what you're looking for.
I live in an old farm house that has zero returns on the 2nd fl and... -
11-03-2011, 11:42 PM
Thread: Zoning a newly renovated attic space
by jramunni- Replies
- 5
- Views
- 367
I would also agree that 5 tons for even 2775 sq...
I would also agree that 5 tons for even 2775 sq ft seems excessive. I do very much agree with your zoning request, we have been providing the controls/dampers to contractors for do that very thing...
-
11-01-2011, 05:01 PM
Thread: Botched HV install -- need help!!
by jramunni- Replies
- 10
- Views
- 1,201
I would interject that the Arzel zoning panel...
I would interject that the Arzel zoning panel would most likely be re-usable with what ever solution you end up with. Zoning with chillers and hot water coils is a very good comfort solution...I...
Results 1 to 25 of 299

