02-26-2008, 07:19 PM
Thread: Static Pressure Problem?
by jdm2447- Replies
- 28
- Views
- 1,458
model # 355aav042080,cnpvp3621acaaaaa,2.5 ton...
model # 355aav042080,cnpvp3621acaaaaa,2.5 ton condensor 165a. Thanks for your help.
-
02-26-2008, 02:59 PM
Thread: Static Pressure Problem?
by jdm2447- Replies
- 28
- Views
- 1,458
The return trunk is already 8x20 (new) and the...
The return trunk is already 8x20 (new) and the return drop is 14x20(new) how much larger do they have to be?A additional 8x26 floor return was added to living room at bottom of staircase,to add...
-
02-26-2008, 01:13 PM
Thread: Static Pressure Problem?
by jdm2447- Replies
- 28
- Views
- 1,458
What should be changed and what are my options?
What should be changed and what are my options?
-
02-25-2008, 07:31 PM
Thread: Static Pressure Problem?
by jdm2447- Replies
- 28
- Views
- 1,458
The only thing that was not changed was the...
The only thing that was not changed was the plenum, top takeoffs and the short trunk at the right side of plenum.Everthing else is new including main trunk,return trunk,return drop and the 2 old pan...
-
02-25-2008, 11:01 AM
Thread: Static Pressure Problem?
by jdm2447- Replies
- 28
- Views
- 1,458
Dash , Are you talking about the short trunk with...
Dash , Are you talking about the short trunk with the take off in post #14 coming out of the plenum ,that only feeds 1 branch to 1 register?
-
02-23-2008, 08:37 PM
Thread: Static Pressure Problem?
by jdm2447- Replies
- 28
- Views
- 1,458
?
?
-
02-19-2008, 02:21 PM
Thread: Static Pressure Problem?
by jdm2447- Replies
- 28
- Views
- 1,458
Typical boot on top of supply,due to location of...
Typical boot on top of supply,due to location of main beam and where supplies go through floor there were not alot of options for installer.The boot rolls 90 then into another 90 out of the top of...
-
02-19-2008, 09:19 AM
Thread: Static Pressure Problem?
by jdm2447- Replies
- 28
- Views
- 1,458
other side of coil
5848This is a picture of the other side of the coil,no changes were made to it.That run just goes to 1st. floor living room.
-
02-18-2008, 10:22 PM
Thread: Static Pressure Problem?
by jdm2447- Replies
- 28
- Views
- 1,458
All seams and joints were sealed with mastic. I...
All seams and joints were sealed with mastic. I had originaly cut a 45 degree angle(see 1st.pic) into top of foundation wall, to have fitting angle down into main trunk,although when the measurements...
-
02-18-2008, 09:01 PM
Thread: Static Pressure Problem?
by jdm2447- Replies
- 28
- Views
- 1,458
The 3X12 goes through the sill, I didn't wont to...
The 3X12 goes through the sill, I didn't wont to remove any more sill,I did notice after he installed that last run that filter went from o % to 70%.The fitting looked kind of restrictive to me sq.to...
-
02-18-2008, 08:35 PM
Thread: Static Pressure Problem?
by jdm2447- Replies
- 28
- Views
- 1,458
static on high is .71 , filter is a 20x25x4...
static on high is .71 , filter is a 20x25x4 merv8, model # 355aav042080,cnpvp3621acaaaaa,2.5 ton condensor 165a. Evolution cont. Main trunk is 8x20 stepped down to 8x16 then a 3x12 that goes through...
-
02-18-2008, 07:58 PM
Thread: Static Pressure Problem?
by jdm2447- Replies
- 28
- Views
- 1,458
pics
5828
5829
5830
5831
5833 -
02-18-2008, 07:49 PM
Thread: Static Pressure Problem?
by jdm2447- Replies
- 28
- Views
- 1,458
Pics
5821
5822
5823
5824
5825 -
02-18-2008, 03:36 PM
Thread: Static Pressure Problem?
by jdm2447- Replies
- 28
- Views
- 1,458
Static Pressure Problem?
I have had new ducts installed and im still getting "change filter message" after a month or so,Im looking for further sugestions to resolve problem,I can provide pictures if needed.Thanks
-
11-21-2007, 09:40 AM
Thread: Duct insulation question
by jdm2447- Replies
- 1
- Views
- 528
Duct insulation question
What is the best type of insulation for ridged duct in an unconditioned crawl space with conc. slab floor? Is 1-1/2 " foil backed sufficient?
-
03-05-2007, 10:35 AM
Thread: Mechanical contractor?
by jdm2447- Replies
- 3
- Views
- 477
Mechanical contractor?
What should I be looking for when getting estimates for duct replacement and or retrofit of a old duct system to work properly with a new high eff. system. What questions would you ask and what...
-
10-29-2006, 12:15 PM
Thread: Old condenser seer?
by jdm2447- Replies
- 1
- Views
- 511
Could anyone tell me what the seer would have...
Could anyone tell me what the seer would have been on this old condensor Intertherm RACZB-030KAWC approx year 1987
-
10-26-2006, 07:59 AM
Thread: Evolution Control
by jdm2447- Replies
- 22
- Views
- 1,598
I spoke with the installer last night he didn't...
I spoke with the installer last night he didn't seem to concearned with static reading,he asked if it was heating the house ok,and said he has not had any problems with these systems.When I asked...
-
10-24-2006, 07:12 PM
Thread: Evolution Control
by jdm2447- Replies
- 22
- Views
- 1,598
pics
http://img253.imageshack.us/img253/9128/1020204ke8.jpg
http://img264.imageshack.us/img264/7671/1020220pg5.jpg ... -
10-23-2006, 04:47 PM
Thread: Evolution Control
by jdm2447- Replies
- 22
- Views
- 1,598
Im still working on it,I have a couple of days...
Im still working on it,I have a couple of days off from work now ,I have a call into the installer(waiting for call back).I contacted another installer who I was going to hire in the 1st. place but...
-
10-18-2006, 08:23 PM
Thread: Evolution Control
by jdm2447- Replies
- 22
- Views
- 1,598
Any opinions?
Any opinions?
-
10-16-2006, 09:26 AM
Thread: Evolution Control
by jdm2447- Replies
- 22
- Views
- 1,598
Dash thanks for the info,who would be the best...
Dash thanks for the info,who would be the best bet to work on the duct system & can any damage result from the .85 on high flame keep in mind that 2nd. stage does not come on that often.Im still...
-
10-15-2006, 08:53 PM
Thread: Evolution Control
by jdm2447- Replies
- 22
- Views
- 1,598
I had a media filter cabinet installed with a...
I had a media filter cabinet installed with a 20x25x4 Bryant merv 8 air filter.Who should I contact to resolve the duct condition.Im a pro auto tech for a new car dealer with vast automotive hvac...
-
10-15-2006, 02:13 PM
Thread: Evolution Control
by jdm2447- Replies
- 22
- Views
- 1,598
The static press. was not checked on the old...
The static press. was not checked on the old system,I had a new 8x24 return drop installed, 2 ceiling returns on 2nd.fl. 1 in each bed rm. and a low return on 1st fl. with a damper to shut of 2nd....
-
10-15-2006, 11:28 AM
Thread: Evolution Control
by jdm2447- Replies
- 22
- Views
- 1,598
I checked the static readings on stat. Heat low...
I checked the static readings on stat.
Heat low 669 cfms,0.27 static
Heat high1331 cfms,0.85 static
A.C. 875cfm,0.48 static. Are any of these reasons for concearn,also while pushing lightly on...