  1. I'm kinda curios as to why he has to call trane...

    I'm kinda curios as to why he has to call trane to help him with some basic troubleshooting. During his checks did he have a thermometer hooked did he check the super heat and subcooling
  2. there should be a performace chart in the unit ,a...

    there should be a performace chart in the unit ,a return air temp and a outside temp and follow the performance curve should be able to know what the pressure should be .the xl15i is a very good...
  3. Replies
    13
    Views
    666

    what was the leaving water temp, did they add...

    what was the leaving water temp, did they add anti freeze to the loop?
  4. that 90000 btu furnace is going to need to move...

    that 90000 btu furnace is going to need to move alot of air ,have they made sure the duct system is large enough
  5. Might be better replacing the package unit with a...

    Might be better replacing the package unit with a smaller one and adding a unit to do the 2nd floor.
    If you have natural gas I would stay with gas heat .
  6. Replies
    19
    Views
    1,004

    I would tell them you want them to refund to you...

    I would tell them you want them to refund to you the price of the rebate.
  7. Replies
    12
    Views
    304

    what is the model number of the outdoor and...

    what is the model number of the outdoor and indoor unit
  8. Replies
    11
    Views
    634

    is that a trane coil if so recheck the model...

    is that a trane coil if so recheck the model number ,or ask the installing contractor for a ari sheet ,because trane does not list that coil as a match .
    have you tried to turn the system to...
  9. Replies
    22
    Views
    839

    Put a t in the drain line in the crawl a foot or...

    Put a t in the drain line in the crawl a foot or two from the wall if possible . The condensate will on drain out of the t if the line freezes ,while not ideal it is better than no heat .
    You can...
  10. you would need to know the size of the heat strip...

    you would need to know the size of the heat strip and airflow to know what the temp rise should be
  11. a ecm motor might save a few bucks a month unless...

    a ecm motor might save a few bucks a month unless it has a crappy duct system then i might cost more
  12. is it a heat pump, gas furnace or electric furnace

    is it a heat pump, gas furnace or electric furnace
  13. of course nest said its not there product ,also...

    of course nest said its not there product ,also if happens 1 in 10 times should be easy to identify the problem
  14. Replies
    11
    Views
    559

    We should go take Yemen , also as as I have said...

    We should go take Yemen , also as as I have said before Obama let's everything turn into a crisis and he is not worth crap at crisis management. in other words he is a worthless potus
  15. Replies
    14
    Views
    301

    a Trane xv 95 gas furnace properly converted ...

    a Trane xv 95 gas furnace properly converted with a heat pump outdoor unit ,
  16. Replies
    2
    Views
    169

    if w1 and w2 are jumpered at the terminal strip ...

    if w1 and w2 are jumpered at the terminal strip they both come on
  17. Replies
    4
    Views
    221

    i think most plastic drain pans have it

    i think most plastic drain pans have it
  18. YOU WANT TO DO WHAT ! :gah: best bet is to call...

    YOU WANT TO DO WHAT ! :gah: best bet is to call a good tech
  19. Replies
    12
    Views
    294

    probably needs a new disconnect

    probably needs a new disconnect
  20. Replies
    79
    Views
    2,528

    What size is the heat strip .

    What size is the heat strip .
  21. Replies
    39
    Views
    2,330

    i use a fluke 325 and a fluke117 .i used to use...

    i use a fluke 325 and a fluke117 .i used to use the fieldpeice sc76 and sc77 and liked them very well except they did not last
  22. Replies
    10
    Views
    429

    just add a supply and return

    just add a supply and return
  23. Replies
    174
    Views
    3,962

    i was born with a dislike for homosexuality and i...

    i was born with a dislike for homosexuality and i cant change, just as they state they were born gay or so they say and they cant change .so why is it im a prejudice biggot for my belief . the...
  24. Replies
    7
    Views
    298

    is the dog shaking off by the return air:grin2:

    is the dog shaking off by the return air:grin2:
  25. a simple static pressure test on the duct system...

    a simple static pressure test on the duct system would determine if it was sufficient ,also the minimum air flow on alot of 5 tons 1750 cfm although 2000 is better if your in a dry climate .
  26. hope you have a big electrical service coming to...

    hope you have a big electrical service coming to the house because if you need 20 kw you need 2big breakers plus some big wire .
    im thinking the furnace needs fixed because it should not be burping...
  27. Replies
    14
    Views
    546

    see if you community college offers hvac classes

    see if you community college offers hvac classes
  28. Replies
    9
    Views
    390

    if the outoor unit is a xl 19i and only 9 years...

    if the outoor unit is a xl 19i and only 9 years old the coil should be under warranty
  29. find a service company that has leak detectors

    find a service company that has leak detectors
  30. Replies
    3
    Views
    266

    sounds like a common problem on older tranes...

    sounds like a common problem on older tranes ,:callpro:
  31. you can get white armacell paint that has uv...

    you can get white armacell paint that has uv protection.
  32. Replies
    16
    Views
    516

    the most efficent match s 15.75 seer with the 5...

    the most efficent match s 15.75 seer with the 5 ton tam7 air handler or the 5 ton tam8 air handler . 5495903 is the the ari # or 6970448 is the other #
  33. Replies
    16
    Views
    516

    the most efficent match s 15.75 seer with the 5...

    the most efficent match s 15.75 seer with the 5 ton tam7 air handler or the 5 ton tam8 air handler . 5495903 is the the ari # or 6970448 is the other #
  34. Replies
    16
    Views
    516

    ​need to merge threads

    ​need to merge threads
  35. Replies
    16
    Views
    516

    if the humidity is staying high your unit is most...

    if the humidity is staying high your unit is most likley over sized, how big is the home
  36. Replies
    7
    Views
    349

    make sure they check the unit refrigerat while in...

    make sure they check the unit refrigerat while in defrost or in cooling mode ,if the indoor txv is bad it could the problem
  37. get the xl824 if wired and set up properly it...

    get the xl824 if wired and set up properly it will slow the blower to dehumidify
  38. That setting is for the fan speed in the fan on...

    That setting is for the fan speed in the fan on position ,you can set it at what ever you want the unit will pick the proper speed while heating or cooling
  39. the xr13 is a little better unit and not much...

    the xr13 is a little better unit and not much more.
  40. Replies
    3
    Views
    297

    make sure the door is on when checking the amp...

    make sure the door is on when checking the amp draw .on oe motors they only list the max ,on some of the universal they list the amps per speed
  41. Yes it is and will improve the overall comfort...

    Yes it is and will improve the overall comfort and efficiency .
  42. ask them to get with there trane tech rep because...

    ask them to get with there trane tech rep because it does not appear to be working correctly ,we have installed several of the xv units and they kick butt . if you bump up the temp in both zones does...
  43. Replies
    1
    Views
    196

    needs a compressor module

    needs a compressor module
  44. Replies
    82
    Views
    3,379

    i see you neighbors good deal quickly fading away

    i see you neighbors good deal quickly fading away
  45. Replies
    82
    Views
    3,379

    did you open the service valves:grin2:

    did you open the service valves:grin2:
  46. yes he is

    yes he is
  47. i got ill listening to him talk about his share...

    i got ill listening to him talk about his share the wealth plan and turned it off
  48. Replies
    7
    Views
    410

    recover it all out and put r22 in it or replace...

    recover it all out and put r22 in it or replace the outdoor unit also .
  49. me to

    me to
  50. after the motor is fixed they need to make sure...

    after the motor is fixed they need to make sure the heat strips did not burn out the overtemp safties