Type: Posts; User: seandarcy

Search: Search took 0.00 seconds.

  1. Replies
    7
    Views
    302

    He did whatever he needed to do to determine the...

    He did whatever he needed to do to determine the static pressure. He determined static pressure then not estimated.

    And yes, I can ask him to test static and heat rise, but, as I understand it,...
  2. Replies
    7
    Views
    302

    He estimates 0.4 currently. Reducing to tap 2...

    He estimates 0.4 currently. Reducing to tap 2 should give ~0.35+ .
  3. Replies
    7
    Views
    302

    Any reason not to reduce cfm ?

    I've got a 6 ton WF legend geo. It's primary use is maintaining 45 deg in a winter house used weekends. 2 zones. x13 ecm fan

    I've got a new hvac guy who's recommending reducing the cfm. He...
  4. Got hit with the stupid stick. 0.25 W/cfm, 2000...

    Got hit with the stupid stick. 0.25 W/cfm, 2000 cfm, 500 W-min, also 500 w-hr, or 0.5 kwr for 72000 btu , ~ 7 kwh/mmbtu. So at $0.15 /kwh, the air handler power costs about $1 / mmbtu. For an all-in...
  5. For an mmbtu of heat, we use an mcf of gas - $13...

    For an mmbtu of heat, we use an mcf of gas - $13 , and 580 kwh of power - at $0.10 / kwh - $58 , or total of $72 !!

    How did I screw this up?
  6. It's an X13 in a six-ton unit. When I look at air...

    It's an X13 in a six-ton unit. When I look at air handlers I see cfm/watt, or the inverse. So assume 0.25 W/cfm, and speeds of 2000 cfm, on a 6 ton air handler. So 500 watts/minute and I get 72 mbtu...
  7. Does AFUE include air handler electric load ?

    I'm trying to compare residential a geo unit with gas. But I can't figure out how to compare the efficiency. The issue is where is the air handler load, and is it material.

    For instance, lets...
  8. waterfurnace legend: digital flowmeter ??

    I've got a 6 ton waterfurnace legend with a vertical liquid flowmeter on the effluent. I'm told it's leaking slowly and I need to replace it.

    I'm also told I should switch to a digital flowmeter....
  9. Waterfurnace Preheat tank mis-installed : does it matter ?

    I have a 6 ton Waterfurnace Legend connected to a preheat tank. It was installed over a year ago. I've just realized, after looking at the Installation Manual that it wasn't installed at it was...
  10. I'm learning a huge amount, and I do appreciate ...

    I'm learning a huge amount, and I do appreciate all the comments.

    But I'm still confused: can I use the X13 (ECM?) motor from WF if I have a barometric bypass installed? I think I understand that...
  11. This is it. He's installing a barometric bypass....

    This is it. He's installing a barometric bypass. I had no clue that made any difference. And, he installed the barometric bypass yesterday!

    Is it difficult/costly to change a barometric by-pass to...
  12. It's not really a warranty issue. I assume both...

    It's not really a warranty issue. I assume both will work, though interestingly the WF site says that an ECM motor has an expected life of 15-18 years, compared to PSC of 10 -12. But, as I said, this...
  13. ECM or PSC blower for zoned WaterFurnace Legend?

    I've got an open-loop 6 ton WaterFurnace Legend at a summer house in Northeast Pa.

    I'll use cooling maybe a week a year. I keep the heat at 55-60 during the winter, except for 4-6 vacation...
  14. geothermal unit with variable speed compressor?

    I plan to install a geothermal in Northeast PA. Primarily heating, maybe 10% cooling. I'd been planning on a 5 ton single stage Waterfurnace unit.

    I've just looked at the new Copeland variable...
  15. Replies
    0
    Views
    799

    Concentric fitting for FHP -> Bruderus

    I'm trying to set up the desuperheater on an FHP ES061 GHP with a Bruderus indirect HW tank. The Bruderus tank has a 1 1/4" CW connection at the bottom, which also serves as the drain valve. HW out...
  16. Replies
    13
    Views
    1,241

    It was the rep for the Florida Heat Pump CT ...

    It was the rep for the Florida Heat Pump CT _distributor_.

    He did no tests. He didn't even open up the unit.

    He asked the contractor to install a flow meter on the ground loop. Said he'd "talk...
  17. Replies
    13
    Views
    1,241

    >>Have the installer check the Total External...

    >>Have the installer check the Total External Static Pressure (TESP).

    >>With a 6 ton unit on a (retrofit?), possible ductwork is undersized for the >>airflow capacity of the heat pump.

    Will...
  18. Replies
    13
    Views
    1,241

    >>Those pressure are way to high for Geo-thermal...

    >>Those pressure are way to high for Geo-thermal unit,

    Page 19 of the ES install manual - Operating Pressures and Temperatures ( R-410A) shows for 50 water temp, stage 1 suction pressure of...
  19. Replies
    13
    Views
    1,241

    >>whats your water pressure set at? This hp...

    >>whats your water pressure set at?

    This hp generates forced hot air. So there's water only on the ground loop side. While the contractor put a temp and pressure gauge on the incoming ground loop,...
  20. Replies
    13
    Views
    1,241

    geo heat pump really whines

    I've just installed a 6-ton Florida Heat Pump ES061 ( with a scroll compressor ) unit in CT, on a ground loop.

    It's really noisy, and located right under the family room. In particular, it has a...
Results 1 to 20 of 20