Search:

Type: Posts; User: Mooshman812

Page 1 of 7 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    16
    Views
    605

    It's definitely more common to be laid off when...

    It's definitely more common to be laid off when in residential, I'm 24 and when I first got out of school I was doing residential and averaging 20 hrs a week this time 2 years ago. Now I'm only...
  2. Replies
    86
    Views
    2,336

    I dont like work either. In fact, I hate it. I...

    I dont like work either. In fact, I hate it. I grew up in the 90's (the generation of lazy Nintendo people) and worked fast food for 9 years and many, many employers before i got into this gig. Like...
  3. Replies
    86
    Views
    2,336

    Hands on, brains on, variety, challenge, and...

    Hands on, brains on, variety, challenge, and money.
  4. Ive done it with phones. Never had an issue....

    Ive done it with phones. Never had an issue. Never used the rice thing and has always worked for me. I usually leave them on for an hour. Use an old 1 gallon pickle jar with a fitting on the lid
  5. Replies
    10
    Views
    533

    Yep. They're right. Get the supply voltage and...

    Yep. They're right. Get the supply voltage and figure out wattage, thats what matters.
  6. HA!!! well played sir!

    HA!!! well played sir!
  7. Replies
    20
    Views
    2,522

    When i lived in lincoln there was a split level...

    When i lived in lincoln there was a split level roof and the aluminum stairwayto transition levels was seemingly used as a support for the power lines. Whenever i did use it i always walked down it...
  8. Replies
    18
    Views
    902

    The valve will work to maintain a minimum of the...

    The valve will work to maintain a minimum of the stamped number (like said, usually 180 or 100) if ambient i high enough then the valve is closed because the system cant reject enough heat to drop...
  9. Replies
    22
    Views
    1,462

    Maybe check the screens on the inlets of the...

    Maybe check the screens on the inlets of the headmaster if they come with them. If you already ordered the new one you should tear the old one apart to see if you can find the cause of the strange...
  10. Replies
    2
    Views
    1,292

    Cheap, thin copper plus stress crack?

    Cheap, thin copper plus stress crack?
  11. Replies
    6
    Views
    1,077

    In my opinion you just won this thread.

    In my opinion you just won this thread.
  12. Replies
    18
    Views
    2,911

    Thats even worse. Very WOS worthy. Good post.

    Thats even worse. Very WOS worthy. Good post.
  13. Replies
    4
    Views
    1,797

    Just one more drink

    Local fast food place, right next door to a bar in a strip mall. When i get there the manager says i found something wierd when i saw the box ay 20 degrees. "Ok, what is it?" Takes me to the outside...
  14. Replies
    18
    Views
    2,911

    When i was in school and we were using the mapp...

    When i was in school and we were using the mapp gas torches i was by no means the top soldering student, but honestly.. i have never seen copper that blackened by mapp or propane, maybe a "handy"...
  15. Replies
    9
    Views
    617

    Air was moving ok. Compared to the others felt...

    Air was moving ok. Compared to the others felt about the same. And yes, they made a section that is not able to see without tools. Not cool.. i was thinking heat exchager issue myself personally.
  16. X2 Maybe its required for new installs. Maybe...

    X2
    Maybe its required for new installs. Maybe check local codes too, your jurisdiction may have not adapted that code yet.
  17. Replies
    9
    Views
    684

    Well if you want to weigh it in, your recovery...

    Well if you want to weigh it in, your recovery cylinder has a tare weight stamped on the collar (not sure if thats the right name. The handle anyway) find a working scale and weigh the drum, subtract...
  18. Replies
    9
    Views
    684

    Does it jave a headmaster? Reciever? Sightglass?...

    Does it jave a headmaster? Reciever? Sightglass? Most charge by sight glass. If you weighed what you pulled out you could weigh new back in.
  19. Heres what i would do. Start a cook cycle,...

    Heres what i would do. Start a cook cycle, towards the end of the cycle get your meter leads on the connections to the speaker at the end of the cook cycle when the fryer should be beeping see if...
  20. 23 years? How is defrost initiated on that?

    23 years? How is defrost initiated on that?
  21. Thread: Tachometer

    by Mooshman812
    Replies
    19
    Views
    1,455

    Anyone used the testo pocketline tach?

    Anyone used the testo pocketline tach?
  22. Replies
    12
    Views
    696

    My lg has an access on top. Although it olny gets...

    My lg has an access on top. Although it olny gets you to the main board. Is there an evaporator bracket that you remove to drop the evaporator? Could the fan be behind it?
  23. Replies
    9
    Views
    617

    Which could also mean that they didnt clran it as...

    Which could also mean that they didnt clran it as well as they claimed. I go back tomorrow. Ill amp it out. Hope its close. Kinda want an RPM measurement tool now. Haha
  24. Thread: Leak test

    by Mooshman812
    Replies
    6
    Views
    1,284

    Never seen yellow hard pipe. That like painted...

    Never seen yellow hard pipe. That like painted black iron?
  25. Replies
    9
    Views
    617

    I may have worded poorly. The firat call 2 months...

    I may have worded poorly. The firat call 2 months ago was for bad inducer. 1 month later we cleaned the soot. Forward to yesterday it was plugged again. I suppose its possible they lacked a thorough...
  26. Replies
    66
    Views
    3,958

    Haha, mo silphos please

    Haha, mo silphos please
  27. Also refrigeration is more steady work year...

    Also refrigeration is more steady work year round. Higher stress, and lots of phoning. Seems like half my job is through the phone. Check in check out, call for approval on repair cost etc etc.
  28. Replies
    9
    Views
    617

    Possible. And yeah, the heat exchanger is a bear....

    Possible. And yeah, the heat exchanger is a bear. Im guessing the only thing i can do is clean it the best i can and hope for the best. Think it would be ok to lower the outlet gas pressure to make...
  29. Replies
    9
    Views
    617

    Sooting issue

    Recent history on this one is found bad inducer 2 months ago, 1 month ago the heat exchanger was plugged with soot. Cleaned out by another tech who said it was very thouroughly cleaned. I go there...
  30. Replies
    2
    Views
    215

    I think youre just supposed to replace them if...

    I think youre just supposed to replace them if something breaks, I used to own one but just got rid of it. Does the stat have a capillary, maybe use a cooking equiptment tstat.
  31. Replies
    9
    Views
    607

    X2 You should have been explained the...

    X2

    You should have been explained the sequence of operations before allowed to try to diagnose them. What is it doing when it is in ice mode
  32. Replies
    18
    Views
    1,820

    So heres my question. Ultrasonic or h10? Its kind...

    So heres my question. Ultrasonic or h10? Its kind of a loaded question but has anyone had a leak that one device could find and the other not?
  33. Thread: Fried

    by Mooshman812
    Replies
    13
    Views
    1,811

    im sure they will happily pay extra for for a...

    im sure they will happily pay extra for for a paragon this time around. Actually, just found out yesterday the 9141 model (I think thats the number) is made in USA. Pretty happy to see that.
  34. Thread: Fried

    by Mooshman812
    Replies
    13
    Views
    1,811

    Looks like a grasslin..

    Looks like a grasslin..
  35. Replies
    15
    Views
    795

    I think what lytning means is what application...

    I think what lytning means is what application the check valve you are referring to is being used in. A/C or refr. Need more specifics.
  36. Replies
    10
    Views
    579

    Liquid is not compressed it is pressurized, with...

    Liquid is not compressed it is pressurized, with the change in pressure comes a change in saturation temperature, higher pressure=higher boiling point. Lower pressure=lower boiling point.. in order...
  37. Replies
    39
    Views
    2,183

    How long did you wait, those mechanical dial...

    How long did you wait, those mechanical dial switches take a bit to cool which causes shutting the blower off
  38. Replies
    19
    Views
    1,242

    By hearing it do you mean the ultrasonic? ...

    By hearing it do you mean the ultrasonic?


    Leak detection is a discipline I am still fairly new too. I will get better but obviously practice and experience are a must.... I hav3 a leak to find...
  39. get the 376!!, i love this thing!! really the...

    get the 376!!, i love this thing!! really the only thing it doesnt have is temp and miroamps.. unless you are going to specialize in something. most of the time that is all i use, its a good looking...
  40. Replies
    19
    Views
    1,242

    Mike19, i was told that the battery operated...

    Mike19, i was told that the battery operated version isnt as good as the plug in. i ordered a new plug in version from my supplier today.... funny though the supplier, Larsons for you mid-western...
  41. Replies
    49
    Views
    2,051

    If its sucking in rainwater you building is in a...

    If its sucking in rainwater you building is in a negative pressure, verify the make up air filters are clean.
  42. Replies
    19
    Views
    1,242

    Anyone?

    Anyone?
  43. Replies
    19
    Views
    1,242

    H10 repair or replace

    I finally had to turn in my yokogawa (or however its pronounced) for repairs. It started reading erratically and didnt seem to be as precise as it once was. Its an older model for sure, atleast 7...
  44. Thread: HVAC apps

    by Mooshman812
    Replies
    4
    Views
    574

    If you search copeland in the play store/...

    If you search copeland in the play store/ appstore they have a few, danfoss makes some and bitzer makes one. Personally I prefer the bitzer as you can only have ready the refrigerants you use. Also...
  45. Replies
    15
    Views
    791

    Mass insecticide.

    Mass insecticide.
  46. Replies
    15
    Views
    791

    They're ok when they're dead. Nu brite c9mes out...

    They're ok when they're dead. Nu brite c9mes out the second I see them. With that many I would probably just grab my torch
  47. Replies
    15
    Views
    791

    Hahaha x2

    Hahaha x2
  48. Replies
    45
    Views
    3,953

    The phrase "a plumbers house always leaks" is...

    The phrase "a plumbers house always leaks" is what comes to mind.
  49. Replies
    69
    Views
    3,517

    Truth, actually the only accounts ive ever sold...

    Truth, actually the only accounts ive ever sold sheaves to are companies that have an EMS. When you tell them reduced energy efficiency they seem to be willing to do whatever they can within reason...
  50. Replies
    69
    Views
    3,517

    With pulleys I mention shorter belt life and...

    With pulleys I mention shorter belt life and overall less efficient operation. Funny ypu mention armaflex. I just had to replace 4 linesets worth of it above a ceiling this week. Company had been...
Results 1 to 50 of 305
Page 1 of 7 1 2 3 4

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine