  1. Is there such a thing as "No such thing as having to many Returns"

    Our contractor installed a new unit (Amana 16 Seer - ASX 16) system (W/ new furnace) a month or so back, and it REALLY works great! Even at 105 outside we can still easily hold 70 degrees inside. ...
  2. Replies
    46
    Views
    2,516

    I would agree with the mini-split system, but...

    I would agree with the mini-split system, but clearly if you have to ask "how to do it", means you DONT know as much as you think you do. You could probably figure out 'how to do it' but why waste...
  3. Replies
    15
    Views
    1,462

    Was able to get some shots, but hard to get the...

    Was able to get some shots, but hard to get the whole system.

    Here is the transisiton they made from the A coil to the supply plenum. Just below is the main return air box that runs parallel to...
  4. Replies
    15
    Views
    1,462

    How many installs are done 100% by the book?

    I was reading through all the install information on the outdoor unit, the furnace, and coil. It details every single step in order from taking it out of the box to leaving the job site!

    I...
  5. Replies
    3
    Views
    1,137

    During the day, outdoor temps are 95*+F and the...

    During the day, outdoor temps are 95*+F and the south side of the house is scorching hot with sun beating on it most all day. The living room and game room take the brundt of that heat.

    At...
  6. Replies
    3
    Views
    1,137

    Here is Floor Plan on the new 4 ton system

    Here is a 'rough' drawing showing the bottom floor of my 2 story house. It should be easy enough to interpret.

    The total downstairs area is a little over 2000 sq ft. The 2.5 ton system was...
  7. Replies
    27
    Views
    1,758

    No, I have not had a static pressure conducted on...

    No, I have not had a static pressure conducted on it. They are coming back early next week for follow up and 'fine-tune' the dampers and ducts and perhaps reconfigure some dip switches on fan A/H...
  8. Replies
    27
    Views
    1,758

    I just had our entire HVAC system replaced in our...

    I just had our entire HVAC system replaced in our house just a week or so ago. I too went through getting bids from 4 different contractors. Prices varried widely too I might add .. even matching...
  9. Replies
    13
    Views
    1,220

    I was at home and observing just about every...

    I was at home and observing just about every step. The condensor/compressor came right out of the sealed box, was put onto a new concrete pad. Electrical connections were restored and new line set...
  10. I kept bits and parts of old system........

    When I had my old Trane complete system taken out the tech's said if I wanted to I could keep the old stuff if I wanted. There is absolutely nothing wrong with it. (Said they can't use it again...
  11. Replies
    13
    Views
    1,220

    Here are some pics........ (can's seem to make...

    Here are some pics........ (can's seem to make link work to actually show the pics in message.)

    This is the house they are working on - 2800 sq ft. 1600 down 1200 up.

    The downstairs has two...
  12. Replies
    31
    Views
    10,349

    Why did they install a "Hard Start Kit"

    Background....

    System outside is a Carrier 2.5 Ton recip compressor about 6 years old. The coil Inside WAS a very old Honeywell 2.0 Ton slab type .
    **Yeah I know, mismatch in compressor and...
  13. Replies
    13
    Views
    1,220

    It's all about proper Installation !

    Long time reading here (learning) mostly - question time now.

    A "consistent" theme here, without regard to system manfufacturer, or even sizing to a degree is It's all about a proper installation....