Search:

Type: Posts; User: richvacr

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. Replies
    21
    Views
    1,093

    So is this like find as many as errors you can...

    So is this like find as many as errors you can game

    Copper to steel on WH
    Dryer Vent
    Flue going down hill
    Draft hood in wrong location - I assume that is what the hole is for
  2. Replies
    10
    Views
    305

    I had Hoshizaki's that I would make seasonal...

    I had Hoshizaki's that I would make seasonal adjustments to - never knew why.

    Also there was a machine just under a year old where it kept backing up every night, ordered replacement but in the...
  3. Replies
    11
    Views
    657

    what pevs me is I work to get customers and earn...

    what pevs me is I work to get customers and earn money
    It seems I can not get some customers but this type of work gets paid
    And there is a lot of this where I am - change t-stat before filters, ...
  4. Replies
    11
    Views
    657

    I think at one time they were installed correctly...

    I think at one time they were installed correctly but really not sure
    I never paid too much attention till the other day
  5. Replies
    11
    Views
    657

    galvanized sheet metal panels new also -

    galvanized sheet metal panels new also -
  6. Replies
    11
    Views
    657

    yes screwed

    yes screwed
  7. Replies
    11
    Views
    657

    The thing is this is not original install but a...

    The thing is this is not original install but a recent addition

    I work on an adjacent business - do not know what is going on otherwise
  8. Replies
    11
    Views
    657

    They are installed

    They are installed
  9. Replies
    11
    Views
    657

    oh thought it was york

    oh thought it was york
  10. Replies
    11
    Views
    657

    economizer on supply side?

    Am I missing something

    http://hvac-talk.com/vbb/images/attach/jpg.gif
  11. Replies
    0
    Views
    173

    York ZJ210 w/ simplicity no heat

    I have a york zj210 VAV with a simplicty board and expansion board and a ICS control for BAS

    Now with a 24v to W1 on simplicity board nada is happening

    the heat - H1 - output on simplicity...
  12. Replies
    128
    Views
    5,731

    i've lived in one of the worst neighborhoods in a...

    i've lived in one of the worst neighborhoods in a top 5 population city and was mugged. the police advised especially after they knew where i lived to buy a gun

    shooting may be fun have not done...
  13. ok

    ok
  14. venting was done with 45s vertical out a one...

    venting was done with 45s vertical out a one story house - 4 i think aprox 15 feet plus 10 for 45s
  15. Modulating Furnace fails every year on open pressure switch

    I have a York PM9 80k btu up modulating furnace, installed in 2006 that has failed on open pressure switch in November the past three years after running for 6 weeks.

    2012 I replace the board and...
  16. Thread: Cooler Door

    by richvacr
    Replies
    1
    Views
    352

    Cooler Door

    I am looking for a used half door for a Victory 4 door freezer/refrigerator

    Does anyone here know who might have one?

    Richard
  17. Replies
    262
    Views
    19,568

    Really A wise man's heart is at his right...

    Really

    A wise man's heart is at his right hand; but a fool's heart at his left. Ecc. 10:2 KJV
  18. Replies
    28
    Views
    2,059

    Good point I asked a few weeks ago and problem...

    Good point
    I asked a few weeks ago and problem has not recurred
  19. Replies
    2
    Views
    398

    Last thing a few days ago is that they are...

    Last thing a few days ago is that they are getting financing to pay bills - so we were told
  20. Replies
    2
    Views
    398

    MTL Cool / Petfresh @ Petco

    Does anyone have experience dealing with MTL Cool out of Quebec Canada?

    Been trying to collect on 3 jobs performed in the states but nothing

    Accounts payable is out of the office and non...
  21. Replies
    28
    Views
    2,059

    Funky looking but t off the same source As for...

    Funky looking but t off the same source
    As for where inside the wall i do not know not in ceiling so either from 3 compartment sink or hand sink
  22. Replies
    28
    Views
    2,059

    If HGV is sticking it is not when I am watching...

    If HGV is sticking it is not when I am watching it
    Dip switches were set to factory default
  23. Replies
    28
    Views
    2,059

    Machine resets - thermistor if it is the problem...

    Machine resets - thermistor if it is the problem is intermittently bad
  24. Replies
    28
    Views
    2,059

    could be but why only the top not the bottom

    could be but why only the top not the bottom
  25. Replies
    28
    Views
    2,059

    I would think faulty thermistor would be more...

    I would think faulty thermistor would be more consistent - at least one out of three cycles

    but i told them i will price a thermistor since it is the cheapest fix
  26. Replies
    28
    Views
    2,059

    Hoshizaki One Beep

    I have a KM1300 SRH stacked units with the top unit every couple days going off on high temperature safety (one beep)

    When I reset and run it everything is close to normal (freeze time is a bit...
  27. Replies
    21
    Views
    2,010

    What is needed is a either a push rod or if the...

    What is needed is a either a push rod or if the door is locked an internal way of forcing it open

    I know when i go into a beer cooler especially that has a padlock I take the padlock with me...
  28. Replies
    11
    Views
    1,025

    Digital or Manual

    I have been tempted to get digital gauges - Testo's I lean towards
    But I wonder how much a difference it could make
    I'd say my sense of touch & hearing play a large roll (well sight to as a giving...
  29. Replies
    9
    Views
    1,297

    Yes I agree but what are people thinking when...

    Yes I agree but what are people thinking when they mount it in the supply
  30. Replies
    9
    Views
    1,297

    Thermostat bulb in supply air

    Thermostat sensor like a A19 mounted so the supply air effects its operation.

    I have come across this a few times and I don't like it. For a while I thought someone did not know the direction of...
  31. Replies
    1
    Views
    710

    Solar powered RTUs

    Does anyone here have info to learn more about solar hvac applications. I looked Lennox thing.

    Is there anything else out there?
  32. Replies
    7
    Views
    1,235

    price of silver: 15% or dynaflow

    I have been using 15% for sometime but the price is getting crazy. Are people switching to cheaper stuff or paying the price.

    Wish I bought a box when it was around $50 then I could sell it on...
  33. Replies
    0
    Views
    348

    Polaris water heat problems

    Having serious problems with a polaris 130 installed since 2003 (w/o problems) at 5000' above sea level.. Polaris when asked said nothing about elevation.

    Not the first on the scene the others...
  34. Replies
    16
    Views
    3,533

    My gripe is the amount of paperwork and their...

    My gripe is the amount of paperwork and their dysfunctional website
    I can not input the proper local tax rate (fm does not have a cert) in the quote but can in the invoice
    Why do I have to re-enter...
  35. Thread: TXV hot swap

    by richvacr
    Replies
    49
    Views
    5,447

    it you have the change the txv because it is...

    it you have the change the txv because it is malfunctioning possibly from debris changing the lld would be a good thing.

    damm i must be slow not sure if it could change it out with presssure...
  36. Replies
    30
    Views
    5,195

    7 rtu in an hour by yourself? it would take me...

    7 rtu in an hour by yourself? it would take me about that long with gear to walk between units

    maybe you use the makita impact not just for screws
  37. Replies
    2
    Views
    1,261

    Thanks that answered a few questions. Now it...

    Thanks that answered a few questions.

    Now it looks like there is a fault with the board's compressor off timer because I had it running for a while before I took the covers off and found it to...
  38. Replies
    2
    Views
    1,261

    Carrier 38tdb Questions

    Today I came upon a Carrier 38tdb060310 with a problem with the condensate pump - replaced that but

    Back up a minute. The unit is running off a single stage tstat (enough wires to convert to 2...
  39. Replies
    12
    Views
    2,054

    As far as i can tell water flow is good the 3/8...

    As far as i can tell water flow is good the 3/8 tubing from the chill pot to the resevoir apears to be at max flow

    Temp controller just a mech tstat remote bulb in resevoir and a freezestat in...
  40. Replies
    12
    Views
    2,054

    filter need to be changed - none on hand but...

    filter need to be changed - none on hand but water flow is good

    to me dirty filters would lead to low suction pressure, chiller cycling on freezestat
  41. Replies
    12
    Views
    2,054

    Forgot another thing did a compressor efficency...

    Forgot another thing did a compressor efficency test packed it and held 10" hg vacuum for 10 mins.
  42. Replies
    12
    Views
    2,054

    I left a few thing out R-134a tech says at...

    I left a few thing out

    R-134a

    tech says at that ambient 25 & 180 psig (I forgot exactly but low is correct)

    when I backed some charge out less then an oz 22 and 175
  43. Replies
    12
    Views
    2,054

    Lobster Tank Marineland ML-25

    I have a lobster tank, that is not getting down to temp, in the enterance to restuarant that tech support and I can not figure out what wrong. Here is the sequence of events. Previously somelse...
  44. Replies
    6
    Views
    908

    i think you are missing the point 1> the 2...

    i think you are missing the point

    1> the 2 evap would be interlocked - that is only one would be connected (electrical & refrigeration) to the outdoor unit at a time - using relays and solenoids...
  45. Replies
    6
    Views
    908

    adding a 5 Evap to Mitsubishi Ductless

    I installed a mitsubishi mxz4a36na 4 zone system
    now there is an addition with a bedroom I was wondering if anyone here has experience with adding a 5th zone say with solenoid coils and dpdt relays...
  46. Replies
    217
    Views
    8,660

    A few years ago inspectors want to carry -...

    A few years ago inspectors want to carry - authority of law enforcement.

    Techs packing could lead to some problems like owner says what you think and tech responding please shoot me (i don't know...
  47. Replies
    3
    Views
    386

    clean house? UV I wonder how effective it is...

    clean house?

    UV I wonder how effective it is - do hospitals use it?

    last thing if it does not kill you it makes you stronger. but the last air cleaner (honeywell...) nearly killed me. only...
  48. Replies
    27
    Views
    2,647

    what is the real deal with cracked heat...

    what is the real deal with cracked heat exchangers?

    the blower makes positive pressure on the exterior of the hx the external pressure is greater then the internal hx pressure so flue gasses...
  49. Replies
    79
    Views
    5,288

    As for the flame sense SANDING I understand is...

    As for the flame sense SANDING I understand is not the recommended method. Scotch-brite because it removes the surface but not effecting the metal - sanding abrades the metal leaving more surface...
  50. Replies
    79
    Views
    5,288

    Installed a York 90%about 2 years ago the first...

    Installed a York 90%about 2 years ago the first winter there were problems with the pressure switch. I found water in it. The switch was mounted downstream from the Draft inducer. I cleaned it out...
Results 1 to 50 of 117
Page 1 of 3 1 2 3