  1. Replies
    8
    Views
    1,815

    thanks for your help

    thanks for your help
  2. Replies
    8
    Views
    1,815

    last question this unit has been converted from...

    last question this unit has been converted from 502 to mp81 does the charge stay the same or is it like the r12 to 134a conversion only use 80%
  3. Replies
    4
    Views
    875

    Checking capacity

    One of my guys is telling me they make a prob you can insert into supply duct and it will tell you total capacity with all the math and readings has anyone heard of this and if so what is it called...
  4. Replies
    8
    Views
    1,815

    The model # GY0894N my other question is how long...

    The model # GY0894N my other question is how long of a line set are the name plate specs designed for before i have to add more ref. to compensate
  5. Replies
    8
    Views
    1,815

    Ice machine charge

    I have a manatowac {sorry for the spelling} I am going to weigh the charge in but not completley sure if I should fine tune with superheat or subcool it is an air cooled condenser with a line set and...
  6. Replies
    26
    Views
    2,819

    I would not except Rheem taking that long we...

    I would not except Rheem taking that long we install Rheem and have never waited more than 2 days you contractor is dragging his feet or does not have a very good relationship with the Rheem tech....
  7. Replies
    10
    Views
    1,973

    Not sure that what i was asking is if anyone out...

    Not sure that what i was asking is if anyone out there had heard anything about it I havent seen or heard it from goodman just a guy at the supply house told one of my techs. this friday.
  8. Replies
    10
    Views
    1,973

    Working on getting the bulliton but have been...

    Working on getting the bulliton but have been told fri. that they want all blankets remove causing damage to the motor windings causing premature failure ill let you know for sure when i have it in...
  9. Replies
    53
    Views
    4,193

    splitting the coil did fix it and yes we put the...

    splitting the coil did fix it and yes we put the factory charge back in it
  10. Replies
    53
    Views
    4,193

    sure makes you fell like a dummy when something...

    sure makes you fell like a dummy when something like this bites you but the up side is I will never forget
  11. Replies
    53
    Views
    4,193

    Ok I just got back in town and looked a little...

    Ok I just got back in town and looked a little closer and figured out what you guys ment by spliting the condensor coil and it was very dirty ckeaned it all looks good now guess I should have looked...
  12. Replies
    53
    Views
    4,193

    When we removed over half the charge head...

    When we removed over half the charge head pressure was still 225 on a 84 degree day Both condenser fans are running and it has been converted to a normal thermastat we have watched it and it is for...
  13. Replies
    53
    Views
    4,193

    I guess im not understanding what you meen by...

    I guess im not understanding what you meen by spliting the coil its just a single row deep its not 2 rows its plubbed every other pipe is a different circuit its about 1 inch thick
  14. Replies
    53
    Views
    4,193

    this unit has a single row condenser coil and a...

    this unit has a single row condenser coil and a single evap coil have changed filters and cleaned coil a couple times cause thats what it looked like
  15. Replies
    53
    Views
    4,193

    High head on YCH180B3L0FA

    Here we go going to be hard to explainn entirly on here but I'll try I have a YCH180B3L0FA 2003 year the compressor went down short to ground on 2 legs replaced compressor found head pressure border...
  16. Replies
    38
    Views
    10,529

    We started using Rheem and Carrier and so far the...

    We started using Rheem and Carrier and so far the main trouble we have seen out of them is Rheem has had an issue with TXV but they have fixed the problem as far as the Carrier goes we haven't seen...
  17. Replies
    38
    Views
    10,529

    I wouldn't argue that! I'm talking in the last...

    I wouldn't argue that! I'm talking in the last 7-8 years Amana/Goodman has been nothing but trouble everything is made in mexico now and alot of times you can't get coils for 3-4 weeks under warrenty...
  18. Dont know about a spritz but most manufacture...

    Dont know about a spritz but most manufacture recommend a professional cleaning 2 times a year on heatpump and in the spring on straight AC. You also need to have the indoor cleaned and all...
  19. Replies
    38
    Views
    10,529

    We have been installing AMANA/goodman since...

    We have been installing AMANA/goodman since before they combined and it is a great product if you dont want it to work all the time and like waiting on parts oh yea then there is the whole warrenty...
  20. Replies
    4
    Views
    1,625

    do they have one too the one i ordered was...

    do they have one too the one i ordered was sporlan and is the trane replacement but I guess you could use and hot gas bypass
  21. Replies
    4
    Views
    1,625

    The replacement is sporlan adrhe

    The replacement is sporlan adrhe
  22. Replies
    5
    Views
    690

    should have been more clear when we check freon...

    should have been more clear when we check freon or charge we always do it by SH/SC
  23. Replies
    17
    Views
    1,001

    waste of time

    waste of time
  24. Replies
    39
    Views
    3,325

    anyone wanting lowest bid isnt a customer you...

    anyone wanting lowest bid isnt a customer you want anyway they are going to be a pain forever they buy the cheapest and want the best its like buying a yugo and wanting a caddy get what you pay for.
  25. Training Classes in or around Nashville TN

    Im tring to find some service manager classes and service tech classes around this area
  26. Replies
    5
    Views
    690

    I agree twice a year but we try to check the...

    I agree twice a year but we try to check the freon when its around 75-80 degrees just to avoid a service call when it hits 90+ but some of that depends on you geographical location
  27. Replies
    6
    Views
    819

    i would check the programming on the stat and...

    i would check the programming on the stat and make sure its right
  28. Replies
    18
    Views
    1,926

    I would not argue the fact its the supply house...

    I would not argue the fact its the supply house it very well could be but i have had others tell me they had the same issues that were in other area now again you could very well be right . I can...
  29. Replies
    18
    Views
    1,926

    For example you have a unit 10 year parts and...

    For example you have a unit 10 year parts and labor warrenty ok No you ac went on last week of july we order an expansion valve 2 weeks later still dont have the part what do you have to do? Ill...
  30. Replies
    18
    Views
    1,926

    This is an interesting question and I found...

    This is an interesting question and I found myself wondering the same due to the fact most have the copeland scroll compressors most have the same contactors,capasitors and other items but I can tell...
  31. Replies
    23
    Views
    2,426

    Any perticular brand or type that you would...

    Any perticular brand or type that you would recomend or will no coil cleaner work mixed 50-50
  32. Replies
    17
    Views
    2,098

    Thats awsome they'll like that

    Thats awsome they'll like that
  33. Replies
    17
    Views
    2,098

    I havent heard the acidic thing but not saying...

    I havent heard the acidic thing but not saying its not true interesting though
  34. Replies
    23
    Views
    2,426

    The reason he will not do the coated coil is due...

    The reason he will not do the coated coil is due to the other stores not having much luck with them so he doesnt see the point in the extra money now there may be differant types of coated coils im...
  35. Replies
    17
    Views
    2,098

    Thanks Skippedover I didnt know the details of...

    Thanks Skippedover I didnt know the details of this pipe have only seen it 1 time but i did recommend changing the pipe and thier going to at some point but the way their looking at it is that its...
  36. Replies
    23
    Views
    2,426

    Refertecbd do you know what this spray on coating...

    Refertecbd do you know what this spray on coating is called would like to at least try something before we expose the new coil. As for covering the food thats the wierd part he does cover all the...
  37. Replies
    17
    Views
    2,098

    The other reason you can vent 90+ with pvc is...

    The other reason you can vent 90+ with pvc is because they have a lower vent gas or flue gas temps. I have seen some 80+ vented with that grey pvc now that bieng said not sure i would do it but it...
  38. Replies
    23
    Views
    2,426

    Walk in cooler coil acid

    Let start by saying I do not work on walk in cooler very much so here goes. We have a BBQ restraunt that has a walk in cooler every 4 years give or take he has a evap coil leaking we replace it all...
  39. Replies
    11
    Views
    1,143

    Pro8000 is a good thermastat but IAQ is wireless...

    Pro8000 is a good thermastat but IAQ is wireless so it can be easier when there arent enough thermastat wires..
  40. Replies
    5
    Views
    1,128

    After you do the whole sealing the house thing...

    After you do the whole sealing the house thing you might look into a truesteam humidifier that is designed for your sq. footage. We have installed several of these and customers seem to really like...
  41. Replies
    11
    Views
    1,143

    If you didnt want to use an outdoor stat you can...

    If you didnt want to use an outdoor stat you can hook it up with a honeywell vision pro IAQ and it will do it all itself. Also Amana makes a dual fuel board that will run the heat pump until it goes...
  42. Replies
    4
    Views
    743

    I can tell you from experience with this exact...

    I can tell you from experience with this exact problem it will never work right your wasting your money. Depending on how old your old coil is it is probably a 10 seer coil and the least you can buy...
  43. We have installed some of these dftd-1 kits and...

    We have installed some of these dftd-1 kits and they will help I can tell you when we have one of these units we install this as a warranty item now that will depend on your contractor but thats the...
  44. Replies
    6
    Views
    1,149

    I can tell you that a goodman/amana unit aint...

    I can tell you that a goodman/amana unit aint worth the time it takes to install them. We have installed hundreds Amana and once goodman and amana combined they went down hill. I've been waiting 3...
  45. Replies
    15
    Views
    1,749

    carrier offers a real good 2 stage system that...

    carrier offers a real good 2 stage system that you can get the whole shubang including thermastat its the infinity series . On the other hand I would stronly recomend the 10 year parts and labor this...
  46. Replies
    21
    Views
    2,708

    The only way to use a R410a condenser with R22...

    The only way to use a R410a condenser with R22 coil is if it is rated for R410a some units are pressure rated for both types otherwise no you cannot mix match without problems down the road
  47. Replies
    21
    Views
    2,708

    I can tell you from experience my company does...

    I can tell you from experience my company does alot of mobile homes with coleman air handlers and they have tried to install r410 condensers with r22 coils and it will not work I can asure you. You...
  48. Replies
    6
    Views
    802

    I have heard the old 30 over 20 over but after...

    I have heard the old 30 over 20 over but after getting in the field it doesnt really work the only absolute method is superheat-subcooling as sideburns has said.
  49. Im just wondering where did you get the combined...

    Im just wondering where did you get the combined seer rating? The reason i ask is I have heard alot of people tell customers that a unit is an 18 seer but they dont see the inprovment on there...
  50. Replies
    14
    Views
    9,313

    trane and american standard can also be a pain i...

    trane and american standard can also be a pain i agree