  1. ACoral, what part of the country are you located?...

    ACoral, what part of the country are you located?

    And what is your typical thermostat set point?
  2. Replies
    23
    Views
    1,302

    ADP coils are the not the same as Trane coils....

    ADP coils are the not the same as Trane coils. It's a third party manufacturer that will get a AHRI rated match with some equipment.
  3. Looking for thermostat with 'range' - to stop short cycle runs

    You can adjust the CPH's (cycles per hour) in the thermostat installation settings. This will increase run times and will result in a wider temp swing with increased humidity removal.

    I would...
  4. Yellow dripping on outside air conditioning coils. Am I screwed?

    No. You're not screwed at all.

    Sounds like the yellow wax is actually the glue that Trane uses on the aluminum fins. I wouldn't be alarmed.

    Run the system, if it doesn't keep the desired temp...
  5. Lenox vs Rheem. Need to replace TWO systems

    Ok. I did a little research with info you gave me previously.

    The fella who quoted you the Rheem systems is named Brent also. He is Brent E.

    I'm Brent R, never went to your house and I install...
  6. I'm a little confused...it's looks like you...

    I'm a little confused...it's looks like you addressed the letter to "Brent"

    Was this another Brent? Because you were not in my service area; I was not able to come out and evaluate your systems.
    ...
  7. It is in the installation service menu. I don't...

    It is in the installation service menu. I don't suggest the homeowner tinker around in these settings - system damage could occur if altered incorrectly.

    Call your installer and have them adjust...
  8. Carrier Greenspeed and Sweating duct work

    In my experience the sweating occurs during dehumidifying. The blower slows way down to lower the evaporator dew point - unfortunately, it also lowers the dew point of the ductwork

    Get your...
  9. Lenox vs Rheem. Need to replace TWO systems

    First thing; did either contractor perform a load calculation? And if so, did they provide you with a copy? The only proper way to determine what size system your home needs is to perform a manual J...
  10. Looking for installer (or helper) in North Atlanta area'

    Hey guys,

    We're a small growing company. Looking for a motivated person for work as an HVAC installer/service tech/plumber - We will train the right candidate in all aspects of HVAC...
  11. Carrier 25VNA8036 diagnostics assessment

    Well, the static pressure isn't great but it is under 1". Suction pressure looks awful high. What was the indoor temp when these photos were taken?

    Why do you think something is wrong? Is it...
  12. Replies
    1,150
    Views
    124,018

    Imperial iManifold Digital Refrigeration Gauge

    Mr. Bill,

    SubCools was right on in his explanation.

    When the evaporator coil saturation temp is above the dew point - no humidity can be removed therefor there is 0% latent load on the coil....
  13. Replies
    1,150
    Views
    124,018

    I was going to suggest looking up the extended...

    I was going to suggest looking up the extended performance data. Contact your local Lennox rep, they should be able to help you out.

    Or...maybe Rundawg (on this site) will have something on the...
  14. Replies
    1,150
    Views
    124,018

    Imperial iManifold Digital Refrigeration Gauge

    The capacity is correct. A portion of the systems three ton capacity is designed for a latent load. You have a 0% latent load.

    Increase the airflow to 450 cfm/ton and your total capacity should...
  15. Replies
    34
    Views
    1,249

    Low RH of DA on new systems?

    I'm not an expert in psychometrics but from what I understand:

    The lower the supply humidity - the larger the coil bypass factor.

    Slow down the air (or correct the charge) and your supply air...
  16. Replies
    47
    Views
    5,417

    Dang. The picture is old and been here before. So...

    Dang. The picture is old and been here before. So the OP made it up? Now I'm even more disappointed in the trade!
  17. Replies
    8
    Views
    434

    x2. JT hit the nail on the head!

    x2. JT hit the nail on the head!
  18. Replies
    18
    Views
    655

    Congrats Chase!

    Congrats Chase!
  19. Replies
    47
    Views
    5,417

    Buford is right. Someone needs to tell the guy...

    Buford is right. Someone needs to tell the guy before he hurts someone!

    And...what kinda tech school did this guy go to? They need a phone call too!
  20. Replies
    47
    Views
    5,417

    Geez! That's scary! Really scary!! Glad no one...

    Geez! That's scary! Really scary!!

    Glad no one was hurt.
  21. Need help on replacing a unit and selecting a contractor

    What part of Georgia are you located in? We're located in the Cumming/Alpharetta area. I would love to give you a quote if you're in our service area. My email is in my profile.

    First thing, Brand...
  22. Replies
    12
    Views
    445

    I've put in plenty of Infinity systems but...

    I've put in plenty of Infinity systems but haven't even seen an "Observer" system in operation so I can't comment.

    My gut answer to your questions is - No.
  23. Replies
    660
    Views
    48,990

    Imperial Tools iConnect (TM)

    Yes it is. I assumed he was talking about the lag in Bluetooth. That's what I get for assuming things.

    The wireless sensors are a slight bit slower but still react quickly.
  24. Replies
    660
    Views
    48,990

    Imperial Tools iConnect (TM)

    Check out this video:

    http://youtu.be/aywnfAh16iY

    I compare the reaction times between the iManifold (iConnect) and several other digital gauges. The fast setting updates four times a second.
  25. Replies
    1,150
    Views
    124,018

    Imperial iManifold Digital Refrigeration Gauge

    Rick, you must be forgetting the meter clocking feature for furnaces! With the meter clocking feature, you can easily calculate airflow via the temp/humidity probes in heat mode on a gas furnace.
  26. Replies
    1,150
    Views
    124,018

    Imperial iManifold Digital Refrigeration Gauge

    Panotaker,

    See this thread for the temp/humidity probe dimensions.

    http://hvac-talk.com/vbb/showthread.php?1609761-Imperial-iManifold-Wireless-Zigbee-Temperature-and-Humidity-Probes-Part-911M...
  27. New Carrier 24VNA924 and T-Stat does not report Model or S/N

    Strange problem. I haven't had any problems with any UI's displaying the 24VNA9's model and serial. I've installed several this year.

    If the controller isn't sure on what condenser is...
  28. Replies
    1,150
    Views
    124,018

    Imperial iManifold Digital Refrigeration Gauge

    That's awesome! If you have any questions, please post them here! We would be glad to help!
  29. Testo 435 is it worth it and reliable? Looks really neat for a mere $1495

    Chaseair, if you looking for easy airflow and btu calculations then get the Imperial iConnect! The 435 is very German and hard to use.. The iConnect is easy and intuitive.
  30. Thread: Trane XV

    by Brent Ridley
    Replies
    5
    Views
    253

    Trane XV

    Post the full model number of the condenser.
  31. Thread: Trane XV

    by Brent Ridley
    Replies
    5
    Views
    253

    From memory; the heat pump modulates down to 25%...

    From memory; the heat pump modulates down to 25% and the A/C goes down to 30%,
  32. Yep. Ford has done away with the ecoline. I...

    Yep. Ford has done away with the ecoline. I really like the new design. Ladders are little hard to get off but I keep a 6' ladder right in the back door to help me reach them.
  33. Ram ProMaster, Transit 2500, Sprinter, or NV2500?

    I have a Ford Transit 250 (not connect). I love it - with the medium height roof, you can fully stand up in the back. That to me is worth a lot!

    We also have a sprinter and 2 year old E250. No...
  34. Replies
    660
    Views
    48,990

    Imperial Tools iConnect (TM)

    Your return air DB was below 70*. The iManifold/iConnect will not calculate airflow with such a little load on the evaporator.
  35. Ok. Thanks for the clarity.

    Ok. Thanks for the clarity.
  36. Replies
    22
    Views
    1,345

    Imanifold mods

    Here's a few pics of a iManfold that someone customized. I don't have any info on it but maybe Stephen R. will come by and give some more insight.


    583771

    583781
  37. Replies
    22
    Views
    1,345

    Imanifold mods

    Here's a few pics of my setup. I carry the iConnect, two pressures, two temp/humidity probes, two strap style pipe thermistors, and a 4" outdoor temp probe.

    583721

    583751

    583731

    583741
  38. Yellow Jacket has licensed the rights to use the...

    Yellow Jacket has licensed the rights to use the technology in the BluVac but put a "Yellow Jacket" stamp on it.
  39. Replies
    66
    Views
    16,125

    Fieldpiece's customer service has been top notch!...

    Fieldpiece's customer service has been top notch! Have you called them yourself? I would suggest you start by calling them - don't trust the counter guys to do this for you.
  40. High-SEER heat pump outdoor units to fit narrow side yards?

    I would look into the Carrier 24VNA9 or 25VNA8 - it's a 18/19 seer 5 stage unit with a VERY small footprint. The 2 and 3 ton condensers have a 25" x 25" footprint.
  41. 3 feet? The iManifold handled a 30 foot drop like...

    3 feet? The iManifold handled a 30 foot drop like it was nothing!

    See this video for how a manifold SHOULD hold up!

    http://youtu.be/KBnW4y75tYA
  42. Replies
    660
    Views
    48,990

    Imperial Tools iConnect (TM)

    JTCHVAC - from the pics; it looks like your second probe isn't mapped as return air. Notice how probe #1 says SADB. Probe #2 just says DB, indicating it hasn't been mapped.

    From the wireless probe...
  43. Yes. The house was already at set temperature. ...

    Yes. The house was already at set temperature.

    Depending on the indoor/outdoor sensible and latent loads - the system capacity could vary as much as 25%.
  44. Thread: Spd2 ?

    by Brent Ridley
    Replies
    15
    Views
    577

    Spd2 ?

    Generally a properly operating system will have a ΔH of 5.7-7.7. Airflow is mainly what will cause a deviation outside these parameters. A refrigerant related issue will cause lower numbers (due to...
  45. Replies
    6
    Views
    545

    Another digital gauge question

    Tech connect allows another person not on the job site to view your measurements in real time.

    Let's say you had a problem. I'm in Georgia and your in California. You called for assistance: I...
  46. Replies
    6
    Views
    545

    Another digital gauge question

    If you can afford it, go for the Imperial iConnect. No other gauge is even close to matching its capabilities. It is absolutely worth the price tag!

    Airflow estimating, real time btu calculations,...
  47. Awesome video Jim!

    Awesome video Jim!
  48. Yes. I usually use a 1/2" step bit.

    Yes. I usually use a 1/2" step bit.
  49. Thread: Spd2 ?

    by Brent Ridley
    Replies
    15
    Views
    577

    Core_d, check out this thread. I made it a few...

    Core_d, check out this thread. I made it a few years ago. It covers calculating Btu/h using the SDP2 (Δh/change in enthalpy) and STA2 (CFM.)
    ...
  50. Replies
    62
    Views
    6,878

    I was using my iPhone 5.

    I was using my iPhone 5.
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Quality Home Comfort Awards