Search:

Type: Posts; User: suptech wally

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Replies
    46
    Views
    4,996

    This is What i did I have a golf umbrella that i...

    This is What i did I have a golf umbrella that i atached a harbor freight magnet to, to attach to any type of unit I have about 20 bucks in it but its PRICELESS
  2. Replies
    13
    Views
    2,576

    You Don't know????????????? That was done with a...

    You Don't know?????????????
    That was done with a hatchet Axes have at least a 3ft handle you could never cut it that close with an ax. OOH?
  3. I'm in it to win it tonite lutenit,I'm drinkin...

    I'm in it to win it tonite lutenit,I'm drinkin wit/uU fup fer
  4. Replies
    5
    Views
    436

    BUMP

    BUMP
  5. Sometimes you have to make Chicken Salad out of...

    Sometimes you have to make Chicken Salad out of Chicken crap.

    The last unit that I've worked on only had 15-16 degree delta T.
    The larger units have had more favorable results out of; however, it...
  6. I used an awl and one of the YJ swedge tools. it...

    I used an awl and one of the YJ swedge tools. it worked well.
    But those smaller coils were designed to feed less refrigerant to the bottom of the coils. I've had better luck with the larger RTU's,If...
  7. Ive used small bolt cutters in the past. It...

    Ive used small bolt cutters in the past. It worked well if i remember. You should consult with carrier, because on some of these units they have kits avalible to replace the accutrol headers. Good...
  8. Replies
    49
    Views
    3,750

    On most of the carlyle oil failures that I've...

    On most of the carlyle oil failures that I've seen Have been from excessive rod bearing wear as this is the beginning of the oil circuit. You can usually see alot of oil spray in the sightglass with...
  9. thanks for the input. Well it seems that our...

    thanks for the input.
    Well it seems that our best opsion is to have the contractor/rep come and yank out the viewport terminal, and replace it with a workstation,we have to purchase envision and...
  10. Well sorry for the bad grammar.LOL Well I talked...

    Well sorry for the bad grammar.LOL
    Well I talked to the installing contractor today.We'll probably have to have a work station installed. I always thought that All new construction came with
    a one...
  11. Alerton Backalk = junk! need input advice.

    Guys here's my situation, Maybe someone can help. I work for a collage
    We have a building with alerton controls, our only way to communicate with
    the controls is a viewport controler/...
  12. Replies
    13
    Views
    963

    Can you use a serial port jumper between the two...

    Can you use a serial port jumper between the two and set up a temporary network enabling comunication between the two it should work.
    this way should be the fastest.
  13. Replies
    13
    Views
    1,493

    Yeh That nu22 has been around for awhile its made...

    Yeh That nu22 has been around for awhile its made by ICOR
    It's a blend I think its A 134a base with buthane and some other refrigerant
    It will probiblly not meet 13 seer standards just my2c
  14. HELP! capillary question and a wierd one

    Today while in A local supply dealer another tech ask me a question that
    stumped me. Here's the Question as I was ASK. HE has a small reach-in
    with a capillary tube that is .036x 120in but he can...
  15. Replies
    24
    Views
    2,155

    HEy my 2cents On alot of carrier units, freeze...

    HEy my 2cents
    On alot of carrier units, freeze protection, for each circuit clips to evap. tubes
    but they are run over the top of blower unit the wires are shorted and cut alot of the times seen...
  16. Replies
    17
    Views
    1,335

    whoa! can't you see there are grown-ups talking...

    whoa! can't you see there are grown-ups talking here.
    post in the residential forum
    :cool:
  17. Replies
    26
    Views
    2,329

    I'LL tell you how to tell you if its a good...

    I'LL tell you how to tell you if its a good meter.
    Leave it on top of your truck befor you head for
    home, IF it shows up at home its a good meter and a keeper
  18. YOU can replace the accutrol orfice header with a...

    YOU can replace the accutrol orfice header with a TXV.BUT
    you are gonna have problems.like a low delta T for one Also get ready to SWAG the charge .no sub cooling loop some times its better to admit...
  19. Replies
    26
    Views
    2,148

    HEY lets also add that by oversizing your...

    HEY lets also add that by oversizing your equiptment you
    have alot more starts therefore causing shortened life
    expectentcy.Which means replacing your equiptment sooner
    and pulling LRA many more...
  20. Replies
    7
    Views
    2,573

    I totally agree with MASTER M on 1sq ft per ton

    I totally agree with MASTER M on 1sq ft per ton
  21. Replies
    3
    Views
    708

    NO, ONLY on trane zsm's some older zsm's only...

    NO, ONLY on trane zsm's some older zsm's only have 4wire
    connections
    and hook up is 1-1 2-2 3-3 and so on
    later
  22. Replies
    10
    Views
    1,350

    Yeah Ive purchesed the book, I too wood like to...

    Yeah Ive purchesed the book, I too wood like to have it on pdf. if anyone has it.
    thanks in advance
  23. Replies
    3
    Views
    708

    go to your local trane dist and buy there ZSM all...

    go to your local trane dist and buy there ZSM all are close to the same .
Results 1 to 23 of 40
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event