  1. Replies
    8
    Views
    911

    WHY do you think the manifold pressure isn't...

    WHY do you think the manifold pressure isn't correct?

    It's rare that is a problem.
  2. Replies
    8
    Views
    1,413

    Edited my mod I know you're kidding, but let's...

    Edited my mod

    I know you're kidding, but let's go easy on the violent speak please.

    Thanks
  3. Replies
    21
    Views
    1,729

    Personally I favor using a wire brush. As an...

    Personally I favor using a wire brush.


    As an alternative, use a $50 bill. Of course it's "used" then and you need to charge for that as supplies.
  4. Replies
    110
    Views
    7,335

    Going back to the original post. I'd say the...

    Going back to the original post. I'd say the problem originated with the sloppy initial diagnosis. With intermittent problems, too many poor repairmen like to run the furnace and then get out ASAP...
  5. The approach I'd use would be to remove one...

    The approach I'd use would be to remove one burner and install a plug in place of the burner orifice so it is completely disconnected. That would require some other adjustments, such as moving the...
  6. Well, you don't have what is commonly called an...

    Well, you don't have what is commonly called an igniter (hot surface igniter). You have an intermittent pilot ignition system where the pilot isn't staying lit.

    That MIGHT be a bad ignition...
  7. Replies
    110
    Views
    7,335

    Heh, heh! I just started in on page 1 and...

    Heh, heh! I just started in on page 1 and figured I would surely be able to read the dramatic conclusion by page 6!

    What a disappointment!
  8. Replies
    36
    Views
    6,227

    What are the odds that the poor guy calls three...

    What are the odds that the poor guy calls three different companies and gets Larry, Moe and Curly out to inspect the furnace?
  9. Replies
    40
    Views
    2,773

    I'd start by reading the gas meter and checking...

    I'd start by reading the gas meter and checking to see if the meter was over read.
  10. Replies
    3
    Views
    1,026

    The furnace manual is at ...

    The furnace manual is at

    http://www.docs.hvacpartners.com/idc/groups/public/documents/techlit/58p,r-13sm.pdf
  11. Replies
    34
    Views
    9,295

    I agree this is likely to be a venting related...

    I agree this is likely to be a venting related problem.


    My suggestion is that you need a way to analyze what's going on with the venting system, and the way to do that is to install a monometer...
  12. I got an Advanced Class amateur Radio license...

    I got an Advanced Class amateur Radio license forty years ago, and that gives me an understanding of electricity and electronic circuitry much beyond that of most HVAC techs.

    Of course, that...
  13. The gas utility that trained me used a variety of...

    The gas utility that trained me used a variety of methods.

    1. Some training on circuit diagrams and how to interpret them.

    2. Wiring boards where students connected up components to create...
  14. Replies
    3
    Views
    1,035

    You really need the adapter to test the system...

    You really need the adapter to test the system properly.

    Without the adapter, you'll typically get 20+ millivolts, and that might drop to zero under the load of a magnet.


    Also, with the...
  15. Replies
    18
    Views
    1,005

    A person who has been working installing and...

    A person who has been working installing and repairing furnaces for 3-5 years might be worth considering. Someone still in school, no.

    Just not the depth of experience or judgment that is needed...
  16. Replies
    9
    Views
    727

    I agree that a flame rollout switch is unlikely...

    I agree that a flame rollout switch is unlikely to be the cause of the problem. If it's opening, it's probably opening for a reason.
  17. Replies
    8
    Views
    519

    Get the whistle fixed. Check your zoning...

    Get the whistle fixed.


    Check your zoning regulations. They may require more clearance to a neighboring property than you have.
  18. In general, under contract law a contractor is...

    In general, under contract law a contractor is entitled to a reasonable opportunity to complete repairs under a guarantee. If they can't do that, you can hire someone who can and charge the...
  19. Replies
    30
    Views
    2,293

    Diogenes went around with a lamp, looking for...

    Diogenes went around with a lamp, looking for one honest man.

    You need a contractor who is both honest and competent. TWICE the problem Diogenes had.


    Good luck.
  20. A CAV furnace isn't as picky about gas input as...

    A CAV furnace isn't as picky about gas input as sealed combustion systems.

    It's probably no especially critical, but I'd change it out to the orifice size specified by the manufacturer. You may...
  21. Replies
    3
    Views
    360

    The gas utility I used to work for sold pulse...

    The gas utility I used to work for sold pulse furnaces. They had a lot of trouble making them work reliably, and after years of sending repair people out to doctor them up, they offered people a...
  22. Oh, so it's FREEEEEEEEEEEEEEEEEEEEEEEEEE is it?...

    Oh, so it's FREEEEEEEEEEEEEEEEEEEEEEEEEE is it?



    In a pig's eye.
  23. Replies
    9
    Views
    1,184

    I'd be suspicious of a dirty pilot burner or...

    I'd be suspicious of a dirty pilot burner or pilot orifice. It doesn't sound like you've taken a careful look at the pilot flame or know what it should look like.

    And a dirty pilot orifice is the...
  24. One that doesn't work.

    One that doesn't work.
  25. Another possibility would be installing a unit...

    Another possibility would be installing a unit heater hanging from the ceiling in the club room. A little noisy but it would bypass the corrosive environment of the pump room and even free up a...