Search:

Type: Posts; User: gevaltech

Search: Search took 0.00 seconds.

  1. Replies
    8
    Views
    908

    Just had one of these installed and starting to...

    Just had one of these installed and starting to learn how to use it. Basic question...is there anyway for a (non-tech) layman to verify that the contractor properly wired up the unit to work with...
  2. Replies
    0
    Views
    575

    Larger Indoor Coil?

    I'm about to get a Keeprite/Tempstar 2 Ton a/c (C4A424GKA) and hi-eff 2-stage furnace (C9MPV75). The contractor is suggesting putting in a larger indoor coil...a 2.5 Ton (ED4x30) rather than the 2...
  3. One other question: Replacing the original 82000...

    One other question:
    Replacing the original 82000 btu Clare in the house built in 1981. I'm going with a Hi-Eff 2-stage Keeprite/Tempstar. It comes either as a 75000 btu or a 50000 btu.

    House is...
  4. Replies
    34
    Views
    3,635

    I'm trying to find a dealer in Toronto area to...

    I'm trying to find a dealer in Toronto area to get a quote on these systems. Can you contact me @gmail?
  5. The contractor who would do the...

    The contractor who would do the Keeprite(Tempstar) VS90 is adamant that a one stage tstat is perfectly adequate. On everything else he, and his company, seems very competent and in line with what I...
  6. I must make a decision fast ... Any pro can...

    I must make a decision fast ...

    Any pro can comment on this?

    I need to decide between the:

    1. Goodman GMV95 and SSX14
    2. Keeprite/Tempstar VS90 and SX2400(TX5300)
    (previous advice...
  7. Ok, just to throw in another alternative, the...

    Ok, just to throw in another alternative, the latest one pushed for a Goodman system ... same basic specs, but another 10% lower than even the Keeprite. The Goodman has the scroll and a Lifetime...
  8. Thanks for your input Bald Loonie. Okay, I will...

    Thanks for your input Bald Loonie. Okay, I will check out doing my own load calc.

    The KeepRite is 92% vs. the AS 96.7%. Bells and whistles seem similar. But any opinion on the stainless steel...
  9. System Replacement Imminent -- Advice Needed

    Newbie here about to replace my original 27 year old furnace and AC. Due to various rebates I am going Hi Efficiency and have interviewed about 7 companies so far.

    My house in Toronto is a 2...