Search:

Type: Posts; User: kangaroogod

Page 1 of 20 1 2 3 4

Search: Search took 0.04 seconds.

  1. Replies
    29
    Views
    856

    Venting a Gas Furnace

    Another option would be to (2) pipe the furnace up the abandoned chimney chase allowing for a 2 pipe system and installing an electric water heater to replace the gas one. Using electric to heat...
  2. Condensing boilers with single pipe vs two pipe loops

    Without replacing or adding a large amount of additional radiation you have a condensing boiler that will not condense in most situations. Your best chance is having an outdoor reset control...
  3. Replies
    4
    Views
    221

    Maybe the liner is kinked/plugged and the unit is...

    Maybe the liner is kinked/plugged and the unit is not venting properly and condensing? Maybe the gas pressure/rise is off? Maybe the connector in inadequate? Perhaps the termination is too short?
  4. Replies
    17
    Views
    493

    Propane line from tank

    I deal with this quite often. The propane supplier will provide us with a regulator at the entrance of the home Outside, we take it from there. In my experience they instal the piping wicked cheap....
  5. Replies
    0
    Views
    179

    Jb dv200 vac pump issue

    Anyone ever have the ballast knob break on a pump? I have never seen this and I had 2 guys break the bolt part internal in the threading this week. Both pumps less than 2yrs old. At first I thought...
  6. Replies
    21
    Views
    1,982

    I sliced my tendons on 2 fingers on rheem 80%...

    I sliced my tendons on 2 fingers on rheem 80% about 12yrs ago. I was in a cast for 4 weeks Rheem could care less. The bottom blower door edge. Another guy I worked with is almost the identical thing...
  7. Replies
    1
    Views
    256

    Looking up the specs, it says "do not install in...

    Looking up the specs, it says "do not install in location that is hot or humid for long periods of time".
  8. The condensate pump is used when you do not have...

    The condensate pump is used when you do not have a gravity drain meaning that you cannot go down maintaining pitch. The example you describe would be a wall unit installed on an interior wall with...
  9. Replies
    9
    Views
    440

    I wouldn't worry about the bent line. It is not...

    I wouldn't worry about the bent line. It is not going to effect operation of any measurable difference. Kinda looks Undesirable as the unit is not centered on the pad.
  10. Replies
    18
    Views
    1,615

    Look at all the white cellulose

    Look at all the white cellulose
  11. Replies
    14
    Views
    914

    Well the 460 is out. Doesn't seem to be much info...

    Well the 460 is out. Doesn't seem to be much info regarding wireless or future app compatibility??? It isn't listed on the fieldpiece site. Ttt and others have them. I'll stay tuned I suppose
  12. Your contractor can hook you up. ...

    Your contractor can hook you up.

    https://www.taco-hvac.com/archives/100-3.4G.pdf
  13. Some like ford, some like Chevy. I personally...

    Some like ford, some like Chevy. I personally like the taco as they have a vacuum breaker installed.
  14. Converting from oil to gas. Furnace is dead. House has hybrid Steam and FA sy...

    Mitsubishi hyperheat mini split. I am in ny and they will keep up just fine into the negative digits.
    As for valves... You do not want valves what go on the steam piping entering the radiator, we...
  15. Converting from oil to gas. Furnace is dead. House has hybrid Steam and FA sy...

    Piping looks descent. I wish the vertical rise out of the top of the boiler was larger but it is what it is. Insulate those pipes!! All piping above the water level should be insulated with...
  16. Replies
    10
    Views
    403

    If you have the equipment,, find a contractor to...

    If you have the equipment,, find a contractor to install it properly for you. Many will not touch it but some will. Most will want to get markup to cover the overheads which is fair. It will be less...
  17. 90% forced air furnace and convert the oil boiler...

    90% forced air furnace and convert the oil boiler to gas. It is a wet base boiler and an easy conversion. Replacing the steam boiler will gain you very very little in efficiency savings. I Of...
  18. Replies
    11
    Views
    1,662

    Tell em it needs to be 4' from the regulator and...

    Tell em it needs to be 4' from the regulator and it's a 2fer
  19. Replies
    28
    Views
    1,344

    Fieldpiece service is the best. I would think it...

    Fieldpiece service is the best. I would think it would be pretty easy to make them highly water resistant. If the k tcouples were moved to the bottom it would create a drip loop and a plastic...
  20. Is this going to be the platform for the app? I...

    Is this going to be the platform for the app? I would imagine the teaser app is still in process?
  21. Replies
    5
    Views
    262

    Most likely it is a standard EAC cabinet and...

    Most likely it is a standard EAC cabinet and converting to a media is am easy task. I believe the merv ratings are up to 11. Personally I would never recommend and EAC over a media.
  22. Replies
    6
    Views
    356

    Find a good contractor that will repair and offer...

    Find a good contractor that will repair and offer you a service contract that covers repairs?
  23. Replies
    17
    Views
    1,648

    I have a couple guys that want digitals and have...

    I have a couple guys that want digitals and have been holding off. I was told 5 weeks 4 weeks ago. If it is going to be next yr I will buy 4's for em. I dunno. I suppose if it is a late release I at...
  24. Replies
    17
    Views
    1,648

    Very very quiet on the app front. Either issues...

    Very very quiet on the app front. Either issues or black ops
  25. Replies
    33
    Views
    1,186

    If the part is available then the coil could be...

    If the part is available then the coil could be replaced. It could
    Cost you 50+% of the cost of a new system so often times it is more cost effective to replace the system for the long term