  1. Replies
    19
    Views
    1,659

    I can wire the motor to turn clockwise or...

    I can wire the motor to turn clockwise or counterclockwise. However, I can't see anything on the fan unit or the manual to indicate which direction the rotation should be and I don't really want to...
  2. Replies
    19
    Views
    1,659

    Rotation direction

    I have a ~1980 Trane Torrivent air handler and just replaced the motor. How do I find out what the correct rotation direction is?
  3. Replies
    19
    Views
    1,316

    7.9 pints per kwh!

    7.9 pints per kwh!
  4. Replies
    19
    Views
    1,316

    No, I'm in Michigan. Just looking for comfort...

    No, I'm in Michigan. Just looking for comfort and energy efficiency. I believe that dehumidifier is the most efficient available.
  5. Replies
    19
    Views
    1,316

    What is the best way to go?

    I am going with a Trane system and am thinking about a 19i only or a 15i combined with a central dehumidifier (http://www.thermastor.com/Ultra-Aire-XT150H/). My thoughts are that the 15i and central...
  6. Replies
    4
    Views
    694

    Oversized ducts

    Pstu,
    Why would oversized ducts decrease energy efficiency and humidity removal?

    :confused:
  7. Replies
    8
    Views
    994

    Thanks to all who replied; I hope WaterFurnace...

    Thanks to all who replied; I hope WaterFurnace comes up with a more advanced design but I can't wait. The Intellizone doesn't seem to measure up to the Infinity or Trane controls.
  8. Replies
    8
    Views
    994

    Waterfurnace with infinity zoning?

    Can Carrier Infinity zoning be used with WaterFurnace 2 stage variable speed ground source heat pumps? Has anyone done this?
  9. Replies
    5
    Views
    1,122

    Ground-source heat pump question

    I live in Michigan and the heat output of ground source heat pumps is inadequate if I size the units for AC. I am considering the 2 stage WaterFurnace Envision series heat pumps. I plan on adding a...
  10. Replies
    17
    Views
    8,939

    So no difference among brands of air handlers...

    So no difference among brands of air handlers that use ECM motors in gauge of sheet metal, ease of adding hydro coils, control of the ECM motor, etc.?
  11. Thread: Twinning

    by rumn8r
    Replies
    20
    Views
    2,232

    RoBoTeq and vtinknocker

    Thanks!

    Merry Christmas
  12. Thread: Twinning

    by rumn8r
    Replies
    20
    Views
    2,232

    Twinning

    Can variable speed air handlers be twinned?
  13. Replies
    17
    Views
    8,939

    Best air handler with ECM for hydro air

    What air handlers should I consider for a hydro air system (hot water coil) that use ECM variable speed motors? I am aware of Carrier and Trane. Are there other manufacturers I should consider? ...
  14. Replies
    52
    Views
    9,527

    Dash, Thanks for the tip on the shared return...

    Dash,

    Thanks for the tip on the shared return with VS air handlers; I will discuss this with the ME.

    Mark,

    Using the duct sizes and the rebalanced register sizes it looks like the registers...
  15. Replies
    52
    Views
    9,527

    I think you might have misunderstood; I currently...

    I think you might have misunderstood; I currently have one air handler for the house and the proposal is to switch to three.
  16. Replies
    52
    Views
    9,527

    Mark, The bedroom ducts run under the living...

    Mark,
    The bedroom ducts run under the living room concrete floor but are insulated, then run up through a closet to the attic and run to each of 3 bedrooms in the attic space but they are insulated....
  17. Replies
    52
    Views
    9,527

    cem-bsee, I think to get enough airflow but I'm...

    cem-bsee,
    I think to get enough airflow but I'm not sure. Both heat and air are oversized for the Main house and the BR wing but the ME specified Trane VS furnaces with high/low fire and 19i AC...
  18. Replies
    52
    Views
    9,527

    Dash,

    Here are the existing registers and ducts and how the ME proposed to rebalance the registers but using the existing ducts. Currently the system is hydro air and the blower is a Trane Climate Changer...
  19. Replies
    52
    Views
    9,527

    Sorry, I meant to write "NOT compatible" and have...

    Sorry, I meant to write "NOT compatible" and have since edited my post.
  20. Replies
    52
    Views
    9,527

    A HVAC contractor emailed me to say that he had a...

    A HVAC contractor emailed me to say that he had a conference call with a couple of Carrier engineers (state and regional) and they were very concerned that the Infinity variable speed blowers would...
  21. Replies
    6
    Views
    620

    Thanks Mark. Very helpful!

    Thanks Mark. Very helpful!
  22. Replies
    8
    Views
    659

    coolguysfl, Good idea. I'll think about that.

    coolguysfl, Good idea. I'll think about that.
  23. Replies
    6
    Views
    620

    Thanks Mark. Do you think heating can be staged...

    Thanks Mark. Do you think heating can be staged by controlling a 2 speed pump and changing the speed of the motor?
  24. Replies
    8
    Views
    659

    Let me word this more precisely: Is there any...

    Let me word this more precisely: Is there any way to use 2 outside units with 2 dual coil inside units in different air handlers (and duct systems) and have them staged so that one is set to 72F...
  25. Replies
    6
    Views
    620

    Does anyone know the answer to this?

    Does anyone know the answer to this?