11-07-2012, 12:31 AM
Thread: Hot Standby Redundancy PLC/DDC
by vas- Replies
- 2
- Views
- 367
Hot Standby Redundancy PLC/DDC
Hi All,
Currently i have a project that required to use hot standby redundancy PLC, which i think it overkill on my equipment as it is a standalone dehumidifier system.
I like to ask have... -
06-04-2012, 08:39 AM
Thread: Chilled water valves and actuator selection
by vas- Replies
- 1
- Views
- 458
Chilled water valves and actuator selection
Hi,
Is it possible to select the chilled water valve and actuator by using ahu coil water flow rate? i have a data of 107.63 l/s but cannot get upstream and downstream pressure from them. :gah:
... -
10-31-2010, 09:16 PM
Thread: How to convert NTC sensor to NTC 20K sensor
by vas- Replies
- 1
- Views
- 856
How to convert NTC sensor to NTC 20K sensor
Hi All,
I am using Carel NTC temperature sensor for my system and HW need to read the temperature when my unit is down but somehow they cannot get the correct reading bcos they software can only... -
01-12-2009, 08:29 PM
Thread: Carel redundancy pCO
by vas- Replies
- 3
- Views
- 385
what i mean is a hot standby redundancy...
what i mean is a hot standby redundancy controller.
-
01-12-2009, 07:55 PM
Thread: Carel redundancy pCO
by vas- Replies
- 3
- Views
- 385
Carel redundancy pCO
Hi all,
Does anyone here have any idea whether that carel have any redundancy pCO? i had check with the sale person but haven't get any reply yet. just wanna try my luck whether anyone had done it... -
09-23-2008, 08:34 PM
Thread: Lon-work FTT-10 interference
by vas- Replies
- 26
- Views
- 4,190
The compressor have a VFD & the comm wire is...
The compressor have a VFD & the comm wire is using 18 AWG shielded cable. Most possible is the network wire that pick up the interference.
-
09-23-2008, 08:05 AM
Thread: Lon-work FTT-10 interference
by vas- Replies
- 26
- Views
- 4,190
Lon-work FTT-10 interference
Hi everyone, i need help from u guys.
My equipment is a third party unit and using lon-work FTT-10 as HLI with the BMS. My problem is when my compressor is activated, it will affect the whole... -
Need Help
Please kindly check for me whether which company carries temperature and humidity sensors, which are to be used in hazardous area. The specifications are as below. I would be greatly appreciative for...
-
07-05-2007, 10:33 PM
Thread: Looking for new DDC controller
by vas- Replies
- 7
- Views
- 2,289
Thank everyone the the info. Currently my company...
Thank everyone the the info. Currently my company is using carel pCO controller. we using Lonwork & Modbus high level interface for most of our project. My company is in asia (Singapore) and we are...
-
07-04-2007, 10:38 PM
Thread: Looking for new DDC controller
by vas- Replies
- 7
- Views
- 2,289
Looking for new DDC controller
Hi everyone,
My company wanted to try other brands DDC controller to replace our current DDC controller. Any recommandation??
Rgds,
Vas -
04-19-2007, 09:25 PM
Thread: My Chw modulating valve cannot fully close
by vas- Replies
- 8
- Views
- 584
Yes. because my offcoil is at 12degC even when my...
Yes. because my offcoil is at 12degC even when my signal for the valve is 0v.
I tried to close the hand valve on my chilled pipe & my offcoil temperature went up to 21degC. that is how i know the... -
04-19-2007, 09:10 PM
Thread: My Chw modulating valve cannot fully close
by vas- Replies
- 8
- Views
- 584
I dunno? But i tot 2000N is strong enough to...
I dunno? But i tot 2000N is strong enough to close the actuator valve with chilled water oni at 55psi. cos i tried a siemens actuator with only 1600N and it can fully closed with the pressure is...
-
04-19-2007, 08:56 PM
Thread: My Chw modulating valve cannot fully close
by vas- Replies
- 8
- Views
- 584
It move to 100% position when i give out 10vdc...
It move to 100% position when i give out 10vdc signal and stuck in 30% open position when i give 0vdc signal. But my staff siad it sometime won't move at all when they test it again.
-
04-19-2007, 08:32 PM
Thread: My Chw modulating valve cannot fully close
by vas- Replies
- 8
- Views
- 584
My Chw modulating valve cannot fully close
Hi guy,
I'm using a Belimo "AV24-MFT2" actuatuor with 2000N. :eek: My problem is it can't fully close when my signal output is 0Vdc. The chilled water supply pressure is only 55psi & 50psi for...