  1. Replies
    0
    Views
    626

    About the TTSCC01 communicating thermostat

    Hi.

    My system is a 2.5 ton York Affinity air-air heat pump with electric strips.
    At our airflow speed setting, which is the lowest possible, we have a noticable difference in air speed between...
  2. Replies
    7
    Views
    1,174

    For those interested, it turns out the system was...

    For those interested, it turns out the system was slighly overcharged.
  3. I' ll investigate further to see if it's an error...

    I' ll investigate further to see if it's an error in measurements or not pure refrigerant.

    Thanks for your time.
  4. Can you explain this seemingly wrong PT relation?

    I got this unused one step 28 oz can of r410a from

    http://marielusa.homestead.com/refrigerants.html

    I measure the can's pressure: 258 psig
    I measure the can temperature: 77 F (room...
  5. Replies
    8
    Views
    1,238

    It is. That is what York recommends as...

    It is.



    That is what York recommends as well.



    They did not check the valve itself, but the temps while heating.
  6. Replies
    8
    Views
    1,238

    If your bulb is horizontal, that is exactly where...

    If your bulb is horizontal, that is exactly where York recommends to install the bulb. Bends are not an issue, that way. It would be near the equalizer line also, on a York coil like mine.

    The...
  7. Replies
    8
    Views
    1,238

    Placement of ID TXV bulb - how critical?

    Instructions say it should be installed on a horizontal run of the vapor line, near the equalizer line. If bulb installation is made on a vertical run, the bulb should be located at least 16 inches...
  8. Replies
    23
    Views
    1,421

    LOL Funny that you mention that. On my old...

    LOL
    Funny that you mention that. On my old system, the electric furnace was later fitted with a heat pump. Only the installer wired it in such a way that the heat pump would stop if electric heat...
  9. Replies
    23
    Views
    1,421

    That would be quite surprising, since no heating...

    That would be quite surprising, since no heating signal (w1 or w2) from the heat pump is connected to the blower/heat strips. Only the tstat is.

    I might have an explanation though, since I didn't...
  10. Replies
    23
    Views
    1,421

    Alright, let me give you more details as a simple...

    Alright, let me give you more details as a simple confirmation of normal behaviour is now slowly turning in yet another worry with this new system.

    York Affinity matched to a York v/s blower...
  11. Replies
    23
    Views
    1,421

    Yes a York Affinity has demand defrost. Isn't...

    Yes a York Affinity has demand defrost.

    Isn't a defrost cycle supposed to make the system go into cooling, thus lower the temperature ?

    Like I said, temp was rising, system stopped and THEN I...
  12. Replies
    23
    Views
    1,421

    EDIT: And also, It was in it`s "hot heat pump"...

    EDIT:

    And also, It was in it`s "hot heat pump" (very low CFM) mode.
  13. Replies
    23
    Views
    1,421

    Thermostat is a Vision Pro IAQ And the heat pump...

    Thermostat is a Vision Pro IAQ
    And the heat pump was not in defrost since the temperature was rising.
  14. Replies
    23
    Views
    1,421

    What happens when a heat pump stops?

    I was checking something near my heat pump when it started heating. I was watching the temp rise when suddenly it stopped. Thermostat was satisfied after 5-10 min.

    What surprised me though is...
  15. Replies
    20
    Views
    1,555

    Assuming that your Luxaire HL5B has the same...

    Assuming that your Luxaire HL5B has the same parts as my York Affinity (really?), I appreciate your comment as it puts me more at ease.

    You are then implying that this is a normal sound.

    I...
  16. Replies
    20
    Views
    1,555

    I really hope that it is only a minor problem,...

    I really hope that it is only a minor problem, given that the system works fine.
    This sound cannot be heard outiside standing next to the compressor. When the system starts, the sound doesn't...
  17. Replies
    20
    Views
    1,555

    Ok. I'll try these guys one more time. I sent...

    Ok.

    I'll try these guys one more time.
    I sent an email to the service manager asking him to confirm that the sound I'm hearing from my line set here; http://youtu.be/YjtUfI3HFpI
    is worrisome...
  18. Replies
    20
    Views
    1,555

    Ok, ok. Since I understand that this is not a...

    Ok, ok.

    Since I understand that this is not a forum where DIY subjects are allowed, and that it is read by many people around the world, I should never attempt to service my own unit when there...
  19. Replies
    20
    Views
    1,555

    I'm fixing it on my own, because I lost...

    I'm fixing it on my own, because I lost confidence in the company. So much so that I'm convinced I'mm doing a better job than they are! So far.

    And like I said, I'm not going to quote emails I...
  20. Replies
    20
    Views
    1,555

    Ok guys. Forget my question. Another thread...

    Ok guys.

    Forget my question. Another thread already answers that same question.
  21. Replies
    20
    Views
    1,555

    Thanks... I think You anticipate a screw up? ...

    Thanks... I think

    You anticipate a screw up?

    Any answer on my question?
  22. Replies
    20
    Views
    1,555

    Stuck in self servicing.

    Yup.
    Here I am in 2012 having bought a brand new top of the line York heat pump installed by "jobbers". (Affinity YZF 16 seer, matched to an MV16C v/s blower)
    And yes, I read about the process of...
  23. Replies
    4
    Views
    765

    Thank you guys. It makes sense that the...

    Thank you guys.

    It makes sense that the instructions would be with the coil.
    I finally discovered that, contrary to what I said previously, there is indeed suction from the p-trap. I then need to...
  24. Replies
    4
    Views
    765

    Is a p-trap needed on a York MV16c ?

    Installation booklet is not mentioning it.
    I also checked the condensate line to see if there was suction, and there doesn't seem to be. How is it possible?

    The reason I ask is because the...
  25. Replies
    7
    Views
    1,174

    Think you beenhere. I suspected it, but thought I...

    Think you beenhere. I suspected it, but thought I was being paranoid.

    As usual you are a very generous and helpful guy.
    Regards.