  1. I'm pretty sure Maxline's driver is EasyIO's old...

    I'm pretty sure Maxline's driver is EasyIO's old drivers and if so it is a P1 driver. The website doesn't have any detailed information.

    -Jeremy
  2. Replies
    2
    Views
    313

    Point modules disabled is an old thong for MBC's...

    Point modules disabled is an old thong for MBC's that is longer used. If you don't ave any points how do you know the modules aren't communicating? There will be no communication unless a point is...
  3. My opinion is the Tridium driver would be best...

    My opinion is the Tridium driver would be best accepted and useful for most contractors.

    If you build a BACnet gateway I would strongly recommend using virtual devices where each P2 device would...
  4. Replies
    14
    Views
    989

    I have used the RS232 version from this company...

    I have used the RS232 version from this company and had good luck with them. This is basically a point-to-point Ethernet connection.
    ...
  5. Replies
    59
    Views
    6,760

    From my limited experience you can have 1 master...

    From my limited experience you can have 1 master type device on the network, either the JACE or the SAGE but never both. Maybe there is a way to make the JACE act as a slave style device and exist...
  6. Replies
    4
    Views
    567

    Data Aire DAPIII issue

    Hey guys,
    I have a site that had 7 existing Data Aire DAPIII units that were communicating via BACnet/IP to the building Automation System but were unreliable. We converted to a Niagara AX based...
  7. There was someone who wrote an online interface...

    There was someone who wrote an online interface to be able to send e-mails and have them show up as Google Talk messages which may still work but Google Talk and XMPP have been obsoleted by Google...
  8. Replies
    6
    Views
    707

    Motor starter coils going bad

    Hello all,
    This is only sort of a controls issue but I am out of ideas and need some help. I service a schools districts controls and as part of that it seems I help with everything related because...
  9. I'm not sure how it works elsewhere but here in...

    I'm not sure how it works elsewhere but here in the US research is typically done by University's which are funded by grants. Grants come about to support something. So although science may not work...
  10. Replies
    15
    Views
    999

    Its been awhile since I had to work with a...

    Its been awhile since I had to work with a Daikain but If I remember the on/off button on the thermostat will override the BAS command, etc since they do not implement a priority array. This means if...
  11. Replies
    4
    Views
    482

    there seems to be an issue with the national...

    there seems to be an issue with the national weather service server where it wants a different date format which is not being provided by AX.

    have to wait for someone to figure out a patch
    ...
  12. Replies
    6
    Views
    465

    The TEC you have talks a proprietary protocol...

    The TEC you have talks a proprietary protocol called P1. Unless you want to convert everything on the wire to another protocol and redo your frontend then you are stuck wit Siemens an P1. There are...
  13. What is needed is a P2 driver for Niagara AX that...

    What is needed is a P2 driver for Niagara AX that allows us to replace Insight. The only current option is to keep insight and export points via BACnet which allows points to be seen but not much...
  14. Replies
    59
    Views
    6,760

    I also could use a copy. Currently working with a...

    I also could use a copy. Currently working with a site where I think some TX01 have been wired wrong since day they were installed.

    -Jeremy
  15. Thread: weather service

    by kc2dnw
    Replies
    7
    Views
    507

    A trick I use to get the correct settings is to...

    A trick I use to get the correct settings is to connect my laptop and use DHCP, then run an IPCONFIG /ALL to see what DNS, GATEWAY & SUBNET are being used on the network. The make sure these are the...
  16. I would use a Tridium Niagara AX based front end,...

    I would use a Tridium Niagara AX based front end, which is available from many vendors, and use the P1 driver for older ATEC's or BACnet MS/TP for the new BACnet versions. There is a P1 driver that...
  17. There appears to be some miscommunication here. ...

    There appears to be some miscommunication here.

    You have Siemens P1 devices and BACnet TEC's. What are you trying to do with these devices. It sounded like you were trying to integrate them into a...
  18. This questions is vague but 2 questions should...

    This questions is vague but 2 questions should help us start to give you an answer

    1) are they P1 ATEC's or BACnet ATEC's?
    2) What management station (frontend software) are you looking to...
  19. Replies
    6
    Views
    543

    Save station saves the currently running...

    Save station saves the currently running configuration to the drive of the JACE or supervisor running the station. Backup station saves a full backup of the station to the hard drive of the computer...
  20. Replies
    4
    Views
    348

    You likely have a code bug in your PPCL which...

    You likely have a code bug in your PPCL which constantly commanding the point in 2 different places to 2 different values.
  21. Replies
    8
    Views
    1,136

    There is no front end or router. There are 4 new...

    There is no front end or router. There are 4 new MACH Stats installed within the last 6 months. I need to tie these into the new system being installed which will have PUP and BACnet. They were...
  22. Replies
    8
    Views
    1,136

    Reliable Controls Mach Stat

    I need some help finding some documentation. We have a site we visited today where we are doing a project which includes replacing some panels, bringing in a bunch of panels using the PUP protocol...
  23. Replies
    1
    Views
    227

    Nothing I have ever seen and we use 3.6...

    Nothing I have ever seen and we use 3.6 extensively right now. Once in edit mode whatever element is selected is moved by the default block size set in your workbench with each push or if you old the...
  24. Replies
    2
    Views
    395

    Metasys uses an interesting architecture in that...

    Metasys uses an interesting architecture in that the "front end" is actually the NAE in the BACnet world. An ADX is just a data archive to store more data a graphics. The system is an Advanced...
  25. The KM Digital controllers only talk KMD digital...

    The KM Digital controllers only talk KMD digital and can not be brought into a front end other then Win Control or TotalControl. We are a KMC distributor and wish there was on option for older sites...