Search:

Type: Posts; User: Gunslinger

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. In one of your closets should be a label telling...

    In one of your closets should be a label telling you the cooling and heat loads for your home. It should state the loads depending upon where your home is located.If you find ot and can not...
  2. To the original poster....You mentioned your...

    To the original poster....You mentioned your future plans include upgrading the windows. Why not try and redo your load calc with the upgraded windows and see what the difference in requirements...
  3. Replies
    10
    Views
    480

    try cool vest

    try cool vest
  4. Replies
    10
    Views
    208

    You can purchase an inexpensive tester for these...

    You can purchase an inexpensive tester for these motors. Go to the dealer tool box and you will see it. The tester will tell you if the motor and control module are working. I think it costs 75 bucks...
  5. Thread: Puzzled

    by Gunslinger
    Replies
    14
    Views
    421

    I would add gas to get subcool close to specs. If...

    I would add gas to get subcool close to specs. If the low side is still high and the high side is low, measure the compressor amps. If not close to RLA, you have an inefficient compressor. Also....
  6. Replies
    17
    Views
    3,361

    or reread post #4

    or reread post #4
  7. Replies
    17
    Views
    3,361

    email is in my profile. email me

    email is in my profile. email me
  8. Same here; inspection item. After inspection, I...

    Same here; inspection item. After inspection, I return to site to check refrigerant levels and usually remove them unless the job is in a peoblematic area.
  9. Replies
    17
    Views
    3,361

    I can tell you how to do it but not in the "open"...

    I can tell you how to do it but not in the "open" forum. You will have to become a professional member. I think you're referring to Gen III. Generation II has a rotary switch. Sorry
  10. I have broken the law, put myself at risk, and...

    I have broken the law, put myself at risk, and defeated some of these POS caps with a Dremel tool. Diversified has one out that uses a very small allen key. When does it end?
  11. Replies
    7
    Views
    260

    It still has a reserve tank. I have a different...

    It still has a reserve tank. I have a different brand I use for loaners and it has a tank in it also.
  12. Replies
    4
    Views
    262

    If the units were sized correctly, it is normal...

    If the units were sized correctly, it is normal for them to "struggle" when the outside temps are above design level. Design level in Washington DC is about 91* I believe. I'll bet your humidity...
  13. Replies
    7
    Views
    260

    The problem with the portable ones is SOMEONE...

    The problem with the portable ones is SOMEONE will have to empty the container from the condensate unless you can run a hose from it to a drain. Another option would be a condensate pump and route it...
  14. Replies
    23
    Views
    697

    I am slightly confused...are you speaking of the...

    I am slightly confused...are you speaking of the copper tubing lines that connect the units together of the copper lines on each unit or all of them? The only reason I can think of for the...
  15. Replies
    4
    Views
    262

    When you state that they are noisy, do you mean...

    When you state that they are noisy, do you mean that there is noise at the supply grills or at the units thenselves? Iif at the supply grills or return grill, that points to inadequate ductwork.
  16. You're correct as you won't see those cooler...

    You're correct as you won't see those cooler temperatures for about 5 months. As a side note, if you can drop your indoor humidity, you'll be comfortable at a higher temperature. I run 45 to 50% and...
  17. Replies
    20
    Views
    652

    I have been using 45% with white flux on copper...

    I have been using 45% with white flux on copper to brass. I braze a 4 or 6 inch stub of copper then switch to 15%. Some guys just use 15% and white flux. Wrap the valve real well with wet rags and...
  18. Your home should be comfortable and livable....

    Your home should be comfortable and livable. Maybe you need someone that is not trying to sell you something that won't help and only cost you $$$$. By the way, what county are you located?
  19. Replies
    22
    Views
    531

    Thanks tool slinger. Geesh, I was only kidding.

    Thanks tool slinger. Geesh, I was only kidding.
  20. Replies
    22
    Views
    531

    You need education yourself. Get a life, get a...

    You need education yourself. Get a life, get a sense of humor.
  21. Replies
    22
    Views
    531

    View Post

    <<It is almost impossible to not be in regular contact with the physical body of the person you are sitting next to.>>

    As long as you sit next to a beautiful model like Hannah Davis, who cares?
  22. How long does the freon chanrge last? If this is...

    How long does the freon chanrge last? If this is a once per year thing, you have more of a chance of it working than if you need freon 2 or 3 times a year. I have used the product. It has slowed the...
  23. Replies
    7
    Views
    480

    If the coil is impacted at all, I pull the coil...

    If the coil is impacted at all, I pull the coil and clean it outdoors. To me, clean in place is not a good alternative in most cases.
  24. Here in Florida,for a 60 sq ft bathroom, I see 5...

    Here in Florida,for a 60 sq ft bathroom, I see 5 inch flex.
  25. Replies
    22
    Views
    1,059

    you can get an ides what is in the walls by...

    you can get an ides what is in the walls by listing the construction materials and thickness. Pull some switch and outlet covers and see what if ant insulation is in there. After you do as accurate...
  26. Replies
    17
    Views
    496

    2* superheat if not overcharged indicates...

    2* superheat if not overcharged indicates metering problem.
  27. Replies
    22
    Views
    1,059

    What does the load calc indicate? Of course...

    What does the load calc indicate? Of course you're doing a load calc, right?
  28. Replies
    109
    Views
    3,261

    According to autozone capacity chart, your...

    According to autozone capacity chart, your vehicle takes 31 oz of refrigerant without rear air. The 4.8L engine makes your vehicle a 2500, correct?
  29. Replies
    109
    Views
    3,261

    I think you can purchase vehicle specific All...

    I think you can purchase vehicle specific All Data cd's for $30.00. It will have a complete manual for your vehicle's systems.
  30. Replies
    19
    Views
    888

    Don't forget if you do this, you'll probably need...

    Don't forget if you do this, you'll probably need to bring in outside air into your system.
  31. Replies
    1
    Views
    252

    Wrightsoft has a huge learning curve but it...

    Wrightsoft has a huge learning curve but it covers most everything. A thorough understanding of manual J will help you a lot.
  32. Replies
    5
    Views
    319

    Tried to give you a rest. GRINS

    Tried to give you a rest. GRINS
  33. Replies
    20
    Views
    746

    I still have R12 in 30 lb drums and single lb...

    I still have R12 in 30 lb drums and single lb cans. Email is in my profile.
  34. Replies
    5
    Views
    319

    Here ya go

    Here ya go
  35. Replies
    53
    Views
    2,898

    The hose with the red ferrule has a shut off on...

    The hose with the red ferrule has a shut off on it. I have found them to leak quite often. As has been mentioned, a better picture would hwlp.
  36. Replies
    109
    Views
    3,261

    Don't forget, autos were using R12 and then r134....

    Don't forget, autos were using R12 and then r134. r22 permiates the rubber of the hoses and leaks.
  37. Replies
    109
    Views
    3,261

    much dinero

    much dinero
  38. Thread: imanifold

    by Gunslinger
    Replies
    4
    Views
    452

    Oh, he's coming to Florida? GRINS

    Oh, he's coming to Florida? GRINS
  39. Replies
    6
    Views
    317

    First, ypu nrrd to remove the pricing as the...

    First, ypu nrrd to remove the pricing as the pricing police will shortly. Pricing varies depending upon location. The Amana I believe has a lifrtime compressor warranty to the original owner. You're...
  40. Replies
    109
    Views
    3,261

    They cycle off around the low 20's so the evap...

    They cycle off around the low 20's so the evap doesn't freeze. Should cycle back on around low 40 psi. On a real hot day, it will not cycle unless you're traveling on a highway. To check the charge...
  41. Replies
    12
    Views
    598

    need more info. Is that 32000 sensible or total?...

    need more info. Is that 32000 sensible or total? You are allowed to take1/2 of the excess latent and add it to the sensible. Need equipment manufacturer's expanded ratings.
  42. Replies
    109
    Views
    3,261

    That was the reason I suggested to clamp off the...

    That was the reason I suggested to clamp off the heter hoses. Blend doors break quite often.


    heatertreater.net
  43. Replies
    5
    Views
    276

    A license should be on the top of your list.

    A license should be on the top of your list.
  44. Replies
    109
    Views
    3,261

    First thing to do is jack up the radiator cap and...

    First thing to do is jack up the radiator cap and run a new van under it! Seriously, clamp off the heater core hioses and see if that keeps the temps steady. That will eliminate a blend door...
  45. Replies
    9
    Views
    528

    You have done what you can and it is time to call...

    You have done what you can and it is time to call a pro.
  46. Replies
    1
    Views
    315

    you might be able to search the sheriff's office...

    you might be able to search the sheriff's office web site and do a search for calls for service.
  47. Replies
    30
    Views
    1,436

    If it is a heat pump,run it in heat mode. The...

    If it is a heat pump,run it in heat mode. The pressure will be higher and you may find the leak.
  48. Replies
    19
    Views
    944

    They do have a lifetime warranty. When they...

    They do have a lifetime warranty. When they break, they're life is over.
  49. Replies
    30
    Views
    1,423

    ya got it right.

    ya got it right.
  50. Have a load calc done with someone who will...

    Have a load calc done with someone who will carefully and ACCURATELY input the parameters and a manual S done correctly. You may be surprised what the result turns out to be.