  1. It is possible that it overheated and broke and...

    It is possible that it overheated and broke and then partially touched back together in another place. In other words, in one 5kw heater there is so many coils (which generally equals about 12 to...
  2. geesh guys! It could simply be dirty flappers. ...

    geesh guys! It could simply be dirty flappers. Ive still got many pulse furnaces out here. And as far as Im concerned they are as safe as any other furnace out there. And arguably more reliable.....
  3. Replies
    5
    Views
    538

    746 watts equals 1 hp. This will get you close. ...

    746 watts equals 1 hp. This will get you close. Most motors have a power factor... This is the efficiency rating of the motor.
  4. Replies
    42
    Views
    4,947

    Did you check the back of the inducer motor, to...

    Did you check the back of the inducer motor, to make sure the restricter plate hasn't come apart or crumbled? Ive had many of headaches over those dumb things.
  5. Replies
    5
    Views
    630

    a weak lilit switch?

    a weak lilit switch?
  6. Yep, I used to have lots of these issues when I...

    Yep, I used to have lots of these issues when I did residential... Sometimes I would have to replace the induced draft motor and that would do it. It never really seemed like it was bad and ran...
  7. Replies
    9
    Views
    1,836

    Im not sure that Ive ever had a condensing...

    Im not sure that Ive ever had a condensing furnace run a stack temp over 140.
  8. Replies
    5
    Views
    732

    I think your unit may be haunted.

    I think your unit may be haunted.
  9. Replies
    14
    Views
    1,168

    Actually the breaker should be sized for 125% of...

    Actually the breaker should be sized for 125% of the load and assuming the wire is proper, 37 amps shouldn't be tripping the breaker on a unit rated at 35.7fla.
  10. Replies
    14
    Views
    1,168

    I certainly wouldn't rule out low voltage at...

    I certainly wouldn't rule out low voltage at 200vac. Thats pretty low really. What size is the breaker?
  11. Replies
    47
    Views
    4,111

    Because The EPA doesn't require you to have a...

    Because The EPA doesn't require you to have a license to buy those items!:censored:
  12. Thread: "P" trap

    by racingfan
    Replies
    2
    Views
    1,053

    Yes, but to be less technical, I generally take a...

    Yes, but to be less technical, I generally take a static pressure reading in the coil section and use 1" for every 1/10" of static. In other words, a reading of .5"w.c. would equal a 5inch trap. I...
  13. Thread: running hot

    by racingfan
    Replies
    71
    Views
    3,571

    225 degrees. I still use the old (rule of thumb)...

    225 degrees. I still use the old (rule of thumb) 126 degrees above ambient on the actualdischarge temp line or about 110 degrees above outdoor ambient on the hot gas line vapor line. This will get...
  14. Replies
    53
    Views
    3,478

    I would have ordered a new face plate and...

    I would have ordered a new face plate and measured it out before install, but im still to this day positive thats what it was.
  15. Replies
    53
    Views
    3,478

    I remember about 10 years ago, we had a brand new...

    I remember about 10 years ago, we had a brand new York furnace we installed that would trip the high limit legitamately just like you are describing. I eventually determined that it was a design...
  16. Replies
    32
    Views
    5,162

    Secondary heat exhanger is PLUGGED. Only time I...

    Secondary heat exhanger is PLUGGED. Only time I have ever seen a high eff furnace trip the roll out.
  17. Replies
    93
    Views
    22,110

    They can't stop you from talking about the union....

    They can't stop you from talking about the union. Its the law and your right!

    The company I work for makes us pay income tax on our truck mileage to and from work.

    It is shown as profit and...
  18. Thread: Seriously

    by racingfan
    Replies
    5
    Views
    423

    1800?

    1800?
  19. Replies
    32
    Views
    5,110

    The only reason this could happen is if A. the...

    The only reason this could happen is if A. the induced draft motor was not running

    B. there is a gas leak in the combustion area

    ...
  20. Look at Dynamic Air Filter company. They have a...

    Look at Dynamic Air Filter company. They have a prefabbed V-bank filter setup with a UV light as well. I sold as an "air scrubber". Didnt like the box myself but the filters and the uv lights are...
  21. Replies
    4
    Views
    1,097

    Fulton Pulse inducer assembly removal?

    Anyone ever replaced an inducer assembly on a fulton? Ive gotta bad one and have it ready to come out... Mother &^%$ I cant figure out how to get the dang thing out. It looks like the air decoupler...
  22. Replies
    2
    Views
    352

    ng = 95.570 therms avg temp 25 degrees elec=...

    ng = 95.570 therms avg temp 25 degrees

    elec= 748 kwh both for 30 days
  23. Replies
    127
    Views
    6,441

    Its soo amazing and flat out makes me mad that it...

    Its soo amazing and flat out makes me mad that it usually takes things like this to happen to people before they open their eyes and see. Im as guilty of this as anyone. Trusting is the hardest...
  24. Replies
    127
    Views
    6,441

    Things are alot better now. I am still staying...

    Things are alot better now. I am still staying at home with her and the family. My wife and I are doing alot of soul searching and getting to know God more than ever. For those of you not...
  25. Replies
    127
    Views
    6,441

    And ya, to the guy that was saying (i think) his...

    And ya, to the guy that was saying (i think) his wife sat at home all day while you were out working for the family to make ends meet. And she started to let the house and everything go. Thats...